USER MANUAL 

 

On-Line UPS 

Model ZS110 

1000VA/2000VA/3000VA 

 
 

 

 

 
 

 

 

 
 
 

 

         
 

 

 

 
 

    Uninterruptible Power Supply System

 

 

 

 
 

 


background image

 

1 Introduction                                                                                 

 

1.

 

1 Description of Commonly Used Symbols 

 

Some or all of the following symbols may be used in this manual and may 

appear in your application process. Therefore, all users should read the 

form carefully and thoroughly. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Symbol & Description

 

Symbol

 

Description

 

 

Caution, danger

 

 

Danger electric shock

 

 

Alternating current (AC)

 

 

Direct current (DC)

 

 

Protective ground

 

 

Recycle

 

 

Do not dispose with ordinary trash

 

 

1. 2 Safety Instructions 

 

1. Read this manual carefully and thoroughly before operation the UPS and 

save this manual properly for future reference. 

2. Do not tear up or shatter the alarm table on the UPS and pay attention to 

it. 

3. Please do not overload the UPS. 

4. The UPS contains large capacity batteries. The case of the UPS must not 

be opened by untrained personnel. Otherwise, it may cause electric 

shock. 

5. Do not short the positive and negative electrodes of battery. Otherwise, it 

may cause electric shock or fire. 

6. Do not plunge or insert any objects into the air vents and other inlets. 

7. Do not store or use the device in the following environment: 

Where there is inflammable gas, corrosive agents or heavy dust 

Where the temperature is very high or low (above 40

 

or below 0

or the humidity is very high(more than 90%) 

Under direct sunlight or close to heating facilities 

Place of strong vibrations 

8. In the event of fire occurring in the vicinity, please use dry powder fire 

extinguishers .The use of liquid fire extinguishing agents may cause 

electric shock. 

 


background image

 

2 Product Description                                                                       

 

The ST-series is an on-line uninterruptible power supply device 

incorporating double-converter technology with single-phase input and 

single-phase output. It offers the high quality power supply with the 

greatest degree of availability and reliability. The 1-3kVA of ST series is 

compact and convenient for users, especially for the basic equipments in 

some areas such as: finance, communication, government, traffic, 

manufacture, education and so on. 

 

2. 1 System Type and Configuration 

 

There are two types of UPS according to the battery configuration: standard 

type and long backup time type, each available in the following ratings: 

1kVA, 2kVA and 3kVA UPS. 

Table 2-1 UPS types and configurations 

 

Type

 

Model

 

Remark

 

1kVA 

ZS110

-1K 

With a 1A internal charger and 3 build-in batteries of 

12V/ 7AH 

2kVA 

ZS110

-2K 

With a 1A internal charger and 6 build-in batteries of   

12V/ 7AH 

Standard 

3kVA 

ZS110

-3K 

With a 1A internal charger and 8 build-in batteries of 

12V/ 7AH 

1kVAS 

ZS110-

1K-KS 

With a 7A internal charger and external battery slot. 

2kVAS 

ZS110-

2K-KS 

With a 7A internal charger and external battery slot. 

Long 

Backup 

Time 

3kVAS 

ZS110-

3K-KS 

With a 7A internal charger and external battery slot. 

 

Note: 

“-KS” model means Long Backup Time

 

2. 2    The Appearance of the UPS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 2-1 The rear panel of ZS110-1K-KS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 2-3 The rear panel of ZS110-2K-KS-ZS110-3K 

* The picture  for back panel is just for reference, it subjects  to change on 

customer’s requirement, please refer to the real subject. 

 

Note

The appearances above are examples with the long backup time, the corresponding 

standard type is without the “External Battery slot”. 

 


background image

 

2. 3 Operating Principle 

 

 

Figure 2-4 The UPS operating principle

 

 

1. Input filter: it filters the input and provides clean AC power to the UPS. 

2. AC/DC converter: In Normal mode, it converts the AC input power to 

regulated DC power, and raises the regulated DC voltage for DC/AC 

converter.   

3. DC/DC converter: Raises the DC Voltage from the battery system to the 

optimum operating voltage for the inverter when the UPS operates in 

Battery mode. 

4. DC/AC inverter: In Normal mode, it utilizes the DC output of the 

AC/DC converter and inverts it into precise, regulated sine wave AC

                                   

power. In Battery mode, it receives energy from the battery through the 

DC/DC converter. 

2 Product Description                                                               

 

5. Bypass: It is very important in the UPS system. In the event of a UPS 

fault that will not lead to UPS shutdown, the load will be automatically 

transferred to the bypass. Meanwhile, the LED indicators will indicate 

 

the fault type, and the fault information will be reported through the 

communication ports. 

6. Charger: The charger of standard UPS provides 1A charging current; and 

long backup time provided 7A charging current. 

7. Battery: Sealed maintenance-free lead –acid battery can be used as the 

DC source of the UPS. 

8.  Output  filter:  It  filters  the  output  and  provides  clean  AC  power  to  the 

load. 

 
 

 


background image

 

3 Installation                                                                                         

 

3. 1 Unpacking Inspection 

 

1. Open the packing box of UPS and take it out, visually examine the unit 

for transit damage. 

2. Check against the accessory lists that the accessories of the UPS are 

present. (Refer to Table 9-1). 

3. Make sure the model is what you wanted from the nameplate on the rear 

panel 

4. If the UPS arrives damaged, or there is any missing accessory or other 

question above, please contact the distributor immediately. 

 
 

3. 2 Installation Notes 

 

1. When locating the UPS, make sure there is no hazardous objects such as 

water, inflammable gas, corrosive agents and so on around the UPS, and 

that the installation environment meets the specifications. 

2. The UPS should not be placed on a side. The air inlet port at the front 

panel and the outlet port on the rear panel and two side panels should not 

be blocked so as to ensure good ventilation. 

3. In case if the UPS is unpacked, installed and used at very low 

temperatures, condensations of water drops may appear. It is necessary 

to wait until the UPS fully dried inside out before proceeding to 

installation and use. Otherwise, they may be a risk of electric shock. 

4. Place the UPS near the utility power source outlet which supplies power 

to the UPS. In any emergency, switch off the main input socket, cut off 

the battery voltage input. All power sockets must be connected with 

ground protection. 

 
 
 

 

10 

3. 3 Cable Connection 

 

3.3.1 Connecting Input and Output Cables 
1. Input cable connection 

If the UPS is connected via the power cable, please use a proper socket 

with over current protection, and pay attention to the capacity of the 

socket: over 10A for ZS110-1K(-KS), over 16A for ZS110-2K(-KS) and 

ZS110-3K(-KS). A side of input wiring has been fixed with the UPS, and 

the other side is just need to plug into the input socket. The wiring 

configuration is shown in the following diagram.

                                                                                         

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3-1 Connection Method of Input   

 

2. Output cable connection   

The output of ZS110-1K(-KS)/ ZS110-2K(-KS)/ ZS110-3K(-KS) all 

available to uses sockets. The total output power shall not exceed 

1kVA/0.8kW, 2kVA/1.6 kW

3kVA/2.4 kW. Simply plug the load power 

cable to the output sockets of UPS to complete connection as shown in 

the following diagram. 

 
 
 
 

 


background image

 

11 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3-2 Connection method of output 

 

3.3.2 Operation Procedure of External Battery for Long Backup 

Time UPS 

The battery connection procedure is very important for long backup model. 

Any incompliance may result in the risk of electric shock. Therefore, the 

following steps must be strictly complied with. 

1. First connect in series the batteries of the pack to ensure proper battery 

voltage that ZS110-1KS for 36VDC, ZS110-2KS for 72VDC, 

ZS110-3KS for 96VDC. 

2. Take out the battery cable delivered with the UPS, one end of the 

external battery cable is a plug for connecting the UPS, the other end has 

3 open wires for connecting the battery pack. 

3. Connect the external battery cable to the battery terminal (DO NOT 

connect the battery socket of the UPS first. Otherwise, it may cause 

electric shock). Connect the red wire to the “+” terminal of the battery. 

The black wire is connected to the “-” terminal of the battery. The 

green/yellow wire is grounded for protection purpose. 

4. Connect the plug of the external battery cable to the external battery   

slot on the rear panel of the UPS to complete the connection procedure. 

 

 

12 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3-3 Battery connection diagram for Long Backup time models 

 

Note

 

The length of the external battery cable is 1.6 m, If users need a longer one, 

please consult the distributor. There is a limit to the length of the external 

battery cable to ensure normal operation of the UPS. 

 

3.3.3 Connecting Communication Cable 
1. Computer interface   

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 


background image

 

13 

Computer interface: The type of signals is provided by the UPS to 

communicate with a host computer through 

communication cable included in the standard 

accessory, User can use special monitor software 

UPSilon in the standard accessory to monitor the UPS 

through the port. 

 

2. Alternative connection of communication 

 
 
 
 
 
 
 
 
 

Intelligent Slot: It is designed for installing the dry contact card, SNMP 

card and 485 card. You can choose for one of them to 

installed 

a

dry contact card: You can utilize monitor function of dry contact to 

manage the power supply directly. 

b

SNMP: It enables you monitor the UPS remotely through Internet. 

485: Central monitor card. 

 

Note: 

Please remove the cover board of the intelligent slot before any card is 

installed. 

 

 

14 

4 Chapter Empty, not present any more                                     

 
 

 


background image

 

15 

5 Operation (LCD model)                                                   

 

 

5.1 Operation Display Panel 

 

 

 

1. ON button: 

Pressing the ON button more than 1 second (buzzer beeps once), the UPS 

system is turned on. 

2. OFF button: 

By pressing this button more than 1 second (buzzer beeps once) turns off 

the UPS system whenever the UPS run under the normal mode/battery 

mode. 

3. Function button 

The Function button provides the following functions: 

a) Battery self- diagnosis: When the UPS ran in normal mode, pressing this 

button more than 2 seconds (buzzer beeps twice) can start the battery 

self-diagnosis. 

b) Silence function in battery/bypass mode 

In battery/bypass mode, when the buzzer beeps, pressing and holding the 

function button for more than 2 seconds (buzzer beeps two times) can 

silence the buzzer. Press the button for more than 2 seconds (buzzer beeps 

twice) again to resume the alarm function 

 

 

16 

c) LCD display screen switch 

Pressing the function button for more than 1 seconds and less than 2 

seconds (buzzer beeps once) to switch LCD display screen   

4 LED indicators 

The LED indicators contains, Bypass indicator, utility power indicator, 

Inverter indicator, Battery indicator. The definition of each indicator is the 

same as LED panel (refer to table 4-1).   

 

5.2

 

Operation Mode 

 

UPS Operation Mode contains normal mode, battery mode and bypass 

mode. Under the three modes, the page showing output voltage and output 

frequency is the main display page. If users need more information about 

UPS, Pressing the function button can initiate display screen switch. If the 

current page is not the main page, UPS will automatically switch back the 

main page after 30 seconds. In order to extend the LCD usage life, the 

backlight will turn off after 1 minute without any switch operation. At this 

point, Users just need to touch any button briefly to turn on the backlight. 

 

5.2.1

 

Normal mode 

When operating in the normal mode, the display of main page on the front 

panel is shown as the figure 5-2. The utility power indicator and the 

Inverter indicator are turned on. Load information area shows load value, 

and the battery level area indicates dynamically when the battery is not 

fully charged (the battery level icons lit one after another circularly). When 

the battery is fully charged, all the level icons are turned on. 

 

1) If the utility power indicator blinks, it indicates that there are problems 

with reversed polarity (L, N) of site wiring or disconnect with ground. 

UPS is still working in normal mode. If the battery indicator is turned on 

at the same time, it shows that the voltage or frequency of the utility 

power is out of the normal input range of the UPS. The UPS works in 

battery mode. 

 


background image

 

17 

 
 
 
 
 
 
 
 
 
 
 

Figure 5-2 Normal Mode 

 

2) If load is more than 100 percent, the buzzer beeps every second, 

meanwhile, the warning icon blinks every second too, reminding that 

UPS is overloaded. You should get rid of some unnecessary loads one by 

one to decrease the loads until the alarm clear 

3) If the battery indicator blinks, it indicates that no battery is connected to 

the UPS or battery voltage is too low. You should check if battery is 

properly connected to the UPS, and press function button more than 2 

seconds to start the battery self-diagnosis. If the connection between 

battery and UPS is confirmed without any problem, it may be due to the 

defect or aging of the battery, please refer to the “troubleshooting” in 

chapter 7 to solve the problem accordingly. 

4) The other four display pages are load percent page, actual load page, 

input information page and the maximum temperature page. 

 

Note

Connection to a power generator has to be made according to the following: 

l

 

Activate the power generator and wait until the operation is stable before 

connecting the output of the power generator to the UPS (be sure that the 

UPS is in idle mode). Then, turn on the UPS according to the startup 

procedure. After the UPS is turned on, the loads are connected one by one. 

l

 

It recommended that the capacity of the generator should double than UPS

.

 

 

18 

5.2.2 Battery Mode 
When operating in the battery mode, the display of main page on the front 

panel is shown as the figure 5-3. The battery indicator and the Inverter 

indicator are turned on. If the utility power indicator blinks at the same time, 

it shows that the utility power is abnormal. Load information area shows 

load value, and bat level area shows current battery capacity. 

 

1) When the UPS is running in battery mode, the alarm will beep every 4 

seconds. If the “Function” key is pressed for more than 2 seconds, the 

alarm will not beep 

silence function

. Press the “Function” key more 

than 2 seconds again to resume the alarm function. 

 

 

 

Figure 5-3 Battery Mode 

 

2) When the battery capacity decreases, the number of battery capacity 

indicators turned on will decrease. If the battery voltage drops to the 

pre-alarm level, the alarm will beep every second to remind the user of 

insufficient battery capacity. 

3) The other four display pages are load percent page, actual load page, 

battery information page and the maximum temperature page. 

 

5.2.3 Bypass Mode 
When operating in bypass mode set up through UPSilon

 

software, the 

display on the front panel is shown as the figure 5-4, the utility power 

indicator and the bypass indicator are turned on. Load information area 

shows load value, and the battery level area indicates dynamically when the 

 


background image

 

19 

battery is not fully charged (the battery level icons lit one after another 

circularly). When the battery is fully charged, all the level icons are turned 

on. 

1) When operating in bypass mode, the UPS beeps every 2 minutes. If the 

“Function” key is pressed for more than 2 seconds, the alarm will not 

beep 

(

silence function

)

. Press the “Function” key more than 2 seconds 

again to resume the alarm function. 

2) If the utility power indicator blinks, it shows that the voltage or 

frequency of the utility power is out of the input range of the UPS or 

there are problems with reversed polarity (L/N) of site wiring or 

disconnect to the ground for protection. 

3) The other four display pages are load percent page, actual load page, 

input information page and the maximum temperature page. 

Notes:

 

When operating in bypass mode, the backup function of the UPS is not 

available and the power used by the load is directly from the utility 

power via internal EMI filter. 

 

 

 

 

 

Figure 5-4 Bypass Mode 

5.2.4 LCD indication of UPS alarm status and faults 
In the event of an UPS fault, UPS enters fault operation mode, at this point, 

the fault icon turns on consistently, the buzzer beeps continuously and the 

data information area shows current fault code (refer to table 6-2), the 

display on the front panel is shown as the figure 5-5, users can switch to 

output page by pressing function button. 

 

20 

 

 

 

 

 

 

 

Figure 5-5 Fault display 

 

When a warning occurred, the fault icon blinks every second, and users can 

switch to the alarm display page shown as the figure 5-6 to check the 

warning code.   

 

 
 
 
 

 

 

Figure 5-6 Alarm display 

 

 


background image

 

21 

5.3 Operating Instructions

   

 
5.3.1 UPS ON/OFF Operation 

Note

 

The battery is fully charged before delivery. However, storage and 

transportation will inevitably cause some charge loss. Therefore, it 

is advisable to charge the battery for 10 hours before using it, so as 

to ensure adequate battery capacity. 

 

1. Turning on the UPS 

The operation of turning on the UPS contains: turning on with utility power 

and turning on without utility power. 

1) Turning on with utility power: 

Connect the mains input to the UPS, press the ON button more than one 

second, UPS starts to turn on. At this point, the LCD begins to conduct 

self-diagnosis (all the LCD indicators are turn on about 4 seconds). A 

few seconds later, the UPS will begin to operate in Normal mode; 

meanwhile, the utility power indicator, inverter indicators will turn on. If 

the utility power is abnormal, the UPS will work in battery mode. 

 

2) Turning on without utility power: 

With no mains input feed to the UPS, press the ON button more than one 

second, ups start to turn on, At this point, the LCD begins to conduct 

self-diagnosis (all the LCD indicators are turn on about 4 seconds). A 

few seconds later, the battery indicator, inverter indicators will be turn on 

to indicate that the UPS is working in battery mode. 

 

3). Powering down the UPS 

The operation of powering down the UPS contains: turning off ups in 

normal mode, turning off ups in battery mode   

4) Completely power down the UPS from Normal mode 

Hold and press the OFF button persistently for more than 1 second to 

 

22 

power off the UPS. If it bas been set up to work in bypass mode by 

software, the bypass indicator will be turned on to indicate that the UPS 

is working in bypass mode. In order to cut off the output from the UPS, 

simply cut off the utility power supply. LCD begins to conduct 

self-diagnosis (all the LCD indicators are turned on about 4 seconds),a 

few seconds later, not any display is shown on the front panel and no 

output is available from the UPS outlets, system completely power down. 

 

5) Completely power down the UPS from Battery mode 

Press the “OFF” button persistently for more than 1 second to power off 

the UPS. When being powered off, the LCD will start self-diagnosis (all 

the LCD indicators are turn on about 4 seconds), a few seconds later, not 

any display is shown on the front panel and no voltage output is available 

from the UPS outlets, system completely power down. 

 

5.3.2 Conducting Battery self-diagnosis 
In UPS operation, users can manually initiate battery self-diagnosis to 

check the battery conditions. There are two methods to initiate the battery 

self-diagnosis: 

1. Through the function button 

In normal mode, press and hold the function for more than 2 seconds 

until the buzzer beeps twice. At this point the indicators (LED7~10) will 

blink cyclically, indicating the UPS has worked in battery mode and the 

battery self-diagnosis has started. The battery self-diagnosis will last for 

10 seconds default. In the event of a battery fault during battery 

self-diagnosis, the UPS will transfer to normal mode automatically. 

2. Through the monitor software 

Users can also initiate battery self-diagnosis through the background 

monitoring software. 

 

 


background image

 

23 

6 Maintenance                                                                                                               

 

6.1 Battery Maintenance 
 

The battery is key component of the UPS. The battery life depends on the 

ambient temperature, charging and discharging times. High ambient 

temperature and deep discharging will shorten the battery life. 

1. Sealed maintenance-free lead –acid battery be used in the standard. 

When being connected to the utility power whether the UPS has been 

turned on or not, the UPS keeps charging the battery and also offers the 

protective function of charging and discharging. 

2. Keep the ambient temperature between 15

 

and 25

 

3. If the UPS has not been used for a long period, charging is recommended 

at the intervals 3 months. 

4. Batteries should not be replaced individually. 

5. Under normal conditions, the battery life lasts 3 to 5 years. In case if the 

battery is found not in good condition, earlier replacement should be 

made. The battery should only be replaced by qualified service 

personnel. 

 

Note:

 

1.Prior to battery replacement, the UPS must be turned off and disconnected 

from utility power. 

2. Metal objects such as rings and watches should be removed. 

3. Use the screwdriver with insulated handle. Tools and other metal objects 

should not be placed on the battery. 

4. Short circuit or reverse connection between the positive and negative 

terminal of the battery is strictly forbidden.

   

 

 

 

 

 

24 

6. 2 Checking UPS function 
 

Every time when conducting field maintenance, please check the regular 

function of the UPS, including: 

1. Check the operation status of the UPS 

If the main voltage is within the specifications, the UPS should operate 

in normal mode; if the main voltage is abnormal, the UPS should operate 

in battery mode. In both cases, there should be no fault indication. 

2. Check the transfer between the UPS operation modes 

Disconnect the main input to simulate a mains failure, the UPS should 

transfer to battery mode and operate normally; then recover the mains 

input, the UPS should transfer to normal mode and operate normally 

3. Check the LED indicators of the UPS 

During the check processes stated above, check that the LED indication 

of the UPS agrees with the UPS operation mode. 

 

 


background image

 

25 

7 Troubleshooting                                                                             

 

In the event of an UPS fault, shoot the trouble according to Table 6-1. If the 

fault still persists, please contact our customer service center. 

Faults

 

Fault/Warning 

code 

Fault icon 

Alarm 

Possible 

cause

 

Solution

 

F01 

on 
constantly 

Beep 
continuously 

Internal 
fault. 

Please 

contact 

the 

distributor or Service center 

F02 

on 
constantly 

Beep 
continuously 

Internal 
fault. 

Please 

contact 

the 

distributor or Service center 

F03 

on 
constantly 

Beep 
continuously 

Internal 
fault. 

Please 

contact 

the 

distributor or Service center 

F04 

on 
constantly 

Beep 
continuously 

The 

UPS 

output 

is 

short 
circuited 

Turn  off  the  UPS.  Remove 
all  loads.  Ensure  that  the 
loads  are  not  failed  or  the 
UPS  has  no  internal  short 
before  turn  on  it  again.  If 
failed,  please  contact  the 
distributor or service center 

F05 

on 
constantly 

Beep 
continuously 

Internal 
fault. 

Please 

contact 

the 

distributor or Service center   

F06 

on 
constantly 

Beep 
continuously 

Internal 
fault. 

Please 

contact 

the 

distributor or Service center 

F07 

on 
constantly 

Beep 
continuously 

Overload 
fault 

Reduce  the  member  of 
loads  connected  to  the 
UPS. 

F08 

on 
constantly 

Beep 
continuously 

Internal 
overheat 

Ensure  that  the  UPS is  not 
overloaded 

and 

the 

ventilation  opening  is  not 
blocked 

and 

ambient 

temperature is not too high. 
Wait for 10 min. for the UPS 
to cool down before turning 
it  on  again.  If  it  does  not 
work.  Please  contact  the 
distributor or service center. 

F09 

on 
constantly 

Beep 
continuously 

The 
charger  of 
the  UPS  is 
defective 

Please 

contact 

the 

distributor or Service center 

A01 

Blink once 
every 
second 

Beep  once 
every 
second 

Overload 
pre-warning 

Reduce  the  member  of 
loads  connected  to  the 
UPS. 

 

26 

7 Troubleshooting                                                                                                     

 

Faults

 

Fault/Warning 

code 

Fault icon 

Alarm 

Possible 

cause

 

Solution

 

A02 

Blink once 

every 

second 

Beep 

continuously 

Battery 
overcharging 

Please 

contact 

the 

distributor 

or 

Service 

center 

A03 

Blink once 

every 

second 

Beep once 

every 

second 

UPS  power 
on abnormal 

Check  the  battery  of  the 
UPS connected properly. 

A04 

Blink once 

every 

second 

Beep once 

every 

second 

Battery 
voltage low 

The  UPS  output  will  be 

cut  off,  please  switch  to 
the backup power. 

A05 

Blink once 

every 

second 

Beep once 

every 

second 

Fan failure 

Ensure that the fan is not 
locked 

A06 

Blink once 

every 

second 

Beep once 

every two 

minutes 

Maybe 
reversed 
polarity (L,N) 
of  site  wiring 

or  disconnect 
with ground.

 

Please check  the  polarity 
of  the  neutral  wiring  and 
the  line  wiring,  ensure 
that The

  green/yellow  wire 

connect  protective  ground 
properly

 

 

Table 7-2 UPS troubleshooting of LCD panel indicator 

 

When you contact the service center, please provide the following information: 

 

Model No and Serial No of the UPS. 

 

The date when the problem arose. 

 

Complete description of the problem, including the panel display, alarm 

warning, and power condition and the load capacity. If the UPS is a long 

backup time model, you may also provide the battery information.

 

 

 

 


background image

 

27 

8 Specifications                                                                                                         

 

8. 1 Electrical 

Model

 

ZS11

0-1K 

ZS110-

1K-KS 

ZS11

0-2K 

ZS110-

2K-KS 

ZS11

0-3K 

ZS110-

3K-KS 

Rating

 

1KVA/800W 

2KVA/1600W 

3KVA/2400W 

Input system 

Single phase & earth ground 

Rated voltage 

220VAC 

Voltage range 

115VAC~300VAC 

Frequency 

50Hz 

Power factor 

0.99 

Input 

Voltage range of 
bypass 

80±5)VAC

~(

286±5)VAC

 

Output system 

Single phase & earth ground 

Rated voltage 

220VAC 

Power factor 

0.8 

Voltage precision 

±

2% 

Normal 
mode 

Output 
frequency 

Battery 
mode 

1.The output frequency synchronizes with the input 

frequency  when  the  input  frequency  is  in  the 
range of 46 Hz

54 Hz 

2.The  output  frequency  is  50Hz  when  the  input 

frequency is not in the range of 46 Hz

54 Hz

 

Inverter overload 
capacity

Utility 

power

25

℃)

 

105%±5%<Load

125%±5% 50s transfer to bypass 

125%±5%< Load <150%±5% 25s transfer to bypass 
Load > 150%±5%,300ms transfer to bypass 

0ms 

Normal mode

←→

  Battery mode

 

Transfer time 

<4ms

Normal mode

←→

Bypass mode

 

Output 

Crest factor 

3:1 

Batteries voltage 

36VDC 

72VDC 

96VDC 

Battery Quantity

 

none 

none 

none 

Battery Type 

Sealed  maintenance-free  lead  –acid  battery  of 
battery voltage 12V/7AH

 

Backup Time

25

℃)

 

Full load

5min (Standard) 

Battery 

Charge current

 

1A 

7A 

1A 

7A 

1A 

7A 

 

28 

8. 2 Mechanical 
 

Model

 

W*H*D(mm)

 

Weight(kg)

 

ZS110-1K 

144×229×350

 

11.5 

ZS110-2K 

190×328×424 

24 

ZS110-3K 

190×328×424

 

28 

ZS110-1K-KS 

144×229×350

 

ZS110-2K-KS 

190×328×424

 

12 

ZS110-3K-KS 

190×328×424

 

12 

 
8. 3 Environmental 

Item

 

Normal range

 

Ambient temperature

 

0

℃~

40

 

Environment humidity 

20%

90%

No condensation

 

Altitude

 

Lower than 1000m: no derating 

Over 1000m :1% derating for every 100m rise 

Storage temperature 

-15

 

45

 

 

 

8. 4 EMC 

Item

 

Standard

 

Level

 

ESD 

IEC61000-4-2 

LEVEL4 

RS 

IEC61000-4-3 

LEVEL3 

EFT 

IEC61000-4-4 

LEVEL4 

Surge 

IEC61000-4-5 

LEVEL4 

 

8. 5 Safety 

Comply with GB4943-2001, IEC62040-1 and CE requirements. 

8. 6 Industry Standard 

Comply with EN62040

YD/T 1095-2000 requirements. 

 

 


background image

 

29 

9 Appendix                                                                                       

 

9.1 Consignment Lists 
 

Model Type 

Accessories 

No 

Machine 

Intelligent monitor software CD 

User Manual 

Standard Model

 

Serial communication cable 

Machine 

Intelligent monitor software CD 

User Manual 

External Battery Cable 

Long backup 

time Model

 

Serial communication cable