Please read the instruction manual carefully before use.

A501ZCBE

(A501ZCBE) consists of the faucet (A501) and cartridge (UZC2000E).

Unique triple filtration system with high performance cartridge removes 13 substances based 
on JIS S 3201.

Use for drinking or cooking only.

The cartridge cannot remove salt (seawater) or metallic ions (except lead) contained in water. 
It is also not capable of converting hard water into soft water.

Cleansui filtration system works when the water pressure is from 0.07MPa to 0.35MPa.

1. About this Product

Instruction manual

Thank you very much for purchasing Cleansui. Read these instructions carefully before use. Installation instruction 

and a warranty card are included with this product and must be retained for future reference.

Contents

Under sink water purifier

1. About this Product 
2. Safety Precautions
3. Important Notes for Operation
4. Irregular Water Flow
5. Names of Parts
6. Features of Cartridge

7. Operating Instructions
8. Maintenance
9. Troubleshooting
10. Replacing the Cartridge
11. After-sales Service
12. Specifications

Warranty

 


background image

Attention

1.本製品について 

Failure to follow the safety precautions can lead to a serious accident. They contain 

extremely important information related to safety and all the precautions must be observed 

without fail.

The following warning labels indicate the items you should follow for your safety.

Indicates failure to observe these instructions can cause minor injury to the user 

or damage to surrounding properties.

Attention

Indicates 

“prohibited” 

actions.

Indicates the parts 

which “should not 

be removed”

Indicates 

“mandatory 

instructions”.

Prohibition

Do Not 

Disassemble

Instruction

Instruction

Instruction

Instruction

The degrees of potential danger and damage that can be caused from any improper usage, 

ignoring the contents of the safety precautions are explained below.

2. Safety Precautions

Handling of filtered water

Please use tap water that meets the local standards for drinking water.

 

It cannot be used to purify hot-spring water, well water or any other water that contains large amounts of 
impurities. Uses of the water filter in this way may be detrimental to your health.

If any part of the system is damaged (such as damaged coating), do not touch the damaged area.

 

This may cause injury, if there is damage, please contact the dealer.

Please consume filtered water as soon as possible

 

When you store filtered water, please store it in a clean container with a sealed cap in a refrigerator. Because 
there is no residual chlorine in the filtered water, bacteria may easily multiply.

Please run the filtered water for at least 15 seconds before using your Cleansui for the 

first time everyday. (for UZC2000E)

 

Because there is no residual chlorine in the filtered water left in the system, bacteria may easily multiply. This 
may cause damage to your health.

Please run the filtered water for at least 1 minute to discharge accumulated water when 

Cleansui has not been used for 2 or more days.

 

Because there is no residual chlorine in the filtered water left in the system, bacteria may easily multiply. This 
may cause damage to your health.

Instructions prior to use

To keep the system clean

Do not use filtered water in fish tanks, etc.

 

When the filtration performance declines through usage, residual chlorine may remain in filtered water. This 
may be fatal to fish.

Prohibition

2

 


background image

× 

Attention

Prohibition

Instruction

Instruction

If water scale. is mixed into filtered water, change the hoses or faucet.

 

Water scale etc. may be mixed into filtered water due to the condition of usage or the period of usage.

If the wateroutlet becomes soiled by splash back., run filtered water for more than 15 
seconds.

 

Bacteria may multiply.

For maintenance of the wateroutlet, clean with a sterilized soft toothbrush etc.

 

Bacteria may multiply.

Do not touch the wateroutlet with your hand or dishcloth.

 

Bacteria may multiply.

Please connect the cartridge and the hoses correctly.

 

If they are connected incorrectly, it may cause the water to become blackened (activated carbon) or cause 
damage or leakages.

Do not refrigerate the device.

 

Doing so will may result in ruptures and leaks.

If the system has not been used for more than 2 weeks, please replace the cartridge.

Please be careful when operating the lever.

 

If the level is closed suddenly, this may result in impacted pipes leading leakage and other damage to the 
pipes.

Ensure that the dedicated faucet is closed when you change cartridge.

 

It may cause property damage by leakages.

If the equipment is not used for a prolonged period of time, close the stop valve or water 
main in the plumbing.

 

It may cause leakages.

If seasonings that contain salt, stick to the metal pipes, the hoses or cartridge, please 
wipe with a clean damp cloth to remove salt.

 

It may cause rust or resin deterioration which leads to damage and leakage.

Make sure that one-touch joint connection is plugged in completely when you change 
cartridge.

 

It may cause property damage by leakages.

Regularly check if there are any leakages or rattling around plumbing.

 

It may cause property damage by leakages.

If you place bleach or chemicals. under the sink, close the cap tightly.

 

Volatile bleach or chemicals. may cause damage or leakage.

Replace cartridge regularly.

 

Recommended cartridge replacement period is 12 months. Continuous usage of the cartridge which is 
exhibiting reduced water volume output, due to clogging, may cause damage and leakage, which may result 
in property damage. Water purifying performance may not be adequate with the cartridge that has passed the 
recommended replacement period.

To prevent filtered water irregularities, leakage and ruptures

To keep the system clean

3

 


background image

Attention

Prohibition

Do Not 

Disassemble

Do not block faucet or connect it to other equipment, such as gas boiler etc.

 

It may cause leakages.

Do not apply strong force or shock to the product.

 

It may cause leakages.

Do not hang heavy objects on the water-outlet pipe or turn with strong force.

It may cause leakages.

Do not disassemble the main body or cartridge of the water filter.

 

It may cause leakages.

 

If the purifier is not working properly, please refer to the section "9. Troubleshooting" before requesting 
maintenance or repairs.

Do not use detergents that contain abrasive compounds or thinners for cleaning the 
faucet, cartridge and the hoses.

 

It may cause leakages.

Never allow acid-based detergent, chlorine-based bleach or vinegar to contact the faucet, 
cartridge or the hoses.

 

It may cause leakages.

Do not allow hot frying pans or kettles to come in close contact with cartridge or the hoses 
under the sink. It may cause property damage by leakages.

 

It may cause leakages.

Do not exceed the stated bending radius of the hoses.

 

6 cm radius is the utmost limit of bending.
It may cause reduction of water volume, damage or leakages.

To prevent filtered water irregularities, leakage and ruptures

4

 


background image

5

Use the recommended Cleansui cartridge with Cleansui faucet.

Do not use this device to filter hot water with a temperature of 35

℃ 

or higher through 

"filtration" mode.

If you do so, the performance of activated carbon is reduced and the filtered water may temporarily exhibit an 
unpleasant odour temporarily.

If the tap water has not run for a long time or it contains red rust (turbidity), please allow the 
water to flow for a while before using the water filter to avoid shortening the cartridge life.

In areas with high water pressure, it may cause water to splash. Please reduce the water flow 
with the stop valve .

In areas with high water pressure, a noise may occur while purifying water. In addition if the 
water volume is too high, the purifying performance may be unsatisfactory. Please adjust the 
volume with the faucet lever or stop valve.

Where the water pressure is extremely low, the water may not come out easily after replacing 
cartridge. In that case, run water for about 10 minutes. The water flow will improve.

3. Important Notes for Operation

 


background image

6

Please follow the steps if the water flow is irregular after the filter has been installed or 
replaced.

 

Allow the filtered water to flow while turning the cartridge 
upside down several times. It will drain out air from inside 
the cartridge.

Mixing faucet (tap water)

Sink

Flexible pipe

Water distribution stopcock

Room temperature
water supply pipe

Lever (control water flow)

"IN.OUT" hoses

Cartridge

Cartridge tray

One-touch joint (Hoses and filter connection parts)

Dedicated faucet
(filtered water)

Installation example

Cartridge (model : UZC2000E)

Hot water

supply pipe

4. Irregular Water Flow

5. Names of Parts

 


background image

Operating the lever

Please use filtered water in the following situation

 

Cooking, Soups and other dishes,                 Coffee, Tea,          Cleaning of raw vegetables,Making baby milk, and others

Please use tap water for dish washing.

Attention

Please be careful when you operate the lever. (If you close the 
lever with too much force, the pipes may be impacted, and it 
may result in damage and leakages)

Attention

Please ensure the wateroutlet is positioned/dirercted into the 
sink bowl, If positioned beyond the range of the sink, the flow 
may soak and damage furniture and other property.

Operating the wateroutlet pipe

The wateroutlet pipe can be moved 360

circularly. Adjust it to an appropriate position.

2. Extended cartridge life.

The cartridge life may vary depending on total amount of water flow, water quality and water pressure etc.

3. The one-touch joint system makes filter replacement easy.

1. Cleansui is a unique triple filtration system with high performance cartridge.

7

6. Features of Cartridge

7. Operating Instructions

Cartridge (model : UZC2000E)

Removes large particles.

Removes chlorine odour, 2-MIB (musty odour), organic 
matter (JIS designated items), trihalomethane, CAT 
(agricultural chemical), and lead dissolved in water.

0.1 micrometre holes on sidewalls of hollow fibre 
membrane can remove bacteria, rust, and solid lead etc.

Cleansui’s

unique

filtration

system

Non-woven fabric

Activated carbon and

ion exchange fibre

Hollow fibre membrane

(polyethylene)

The 1st filter

The 2nd filter

The 3rd filter

Minerals

Free residual chlorine

Turbidity(Rust, Bacteria etc.)

Trihalomethanes

Chloroform

Bromodichloromethane

Dibromochloromethane

Bromoform

Soluble Lead

CAT(chemicals/pesticides)

2-MIB(molds)

Tetrachloroethylene

Trichloroethylene

1,1,1-trichloroethane

1

2

3

4

5

6

7

8

9

 10

 11

12

13

The 3rd filter

】 

Hollow

fibre

membrane

The 1st filter

Non-woven

fabric

The 2st filter

】 

+

Activated

carbon

Ion

exchange

fibre

Tasty & clean water with minerals intact

ON

OFF

OFF

ON

Don’t apply

excessive pressure

spin 360

°

wateroutlet pipe

wateroutlet

 


background image

8

8. Maintenance

Please clean the wateroutlet with a sterilized soft
toothbrush.

Please wipe the product with a moist soft cloth and
then use a dry cloth to remove any remaining dirt.

If it is very dirty, use a soft cloth with neutral
detergent for first wipe, then wipe it with a wet cloth
finally, remove remaining dirt with a dry cloth.

When cleaning it with a sponge that does not require detergent,
please do not wipe any text or writing that appears on the product.

If dirt on the product is not cleaned immediately, it may be difficult to remove afterwards. In
order to ensure the product is in optimum condition, we recommend that regular maintenance be
performed on the product.

Please do not use the following items, as doing so may cause
discolouration or other damage to it, and can cause property
damage by leakage.

Detergents containing acid, alkaline or chlorine

Solvents such as gasoline, lacquer thinners, lacquer,
alcohol and oil

Detergent containing abrasive compounds

Nylon brushes

Attention

Regular Inspection

In order to use this system safely and effectively, please inspect it regularly.

Faucet loosening (About once a month)

If you continuously use a loose faucet, the stress
may be applied to the pipes, and it may cause
property damage by leakage.

Leakage around the pipes

(About once a month)

Please check for leakage around the pipes.
The leakage is due to ageing and friction, may
cause property damage.

Rotation of the wateroutlet pipe
(About once a month)

Rotate the wateroutlet pipe from side to side
occasionally.
If the wateroutlet pipe is not rotated for a long
period of time, it may be affected by water stains
which may subsequently affect its rotational
capabilities.

No leakage

Check

Check if it is loose (rattling)

× 

Loose (rattling)

Please rotate the wateroutlet pipe from side to side occasionally.

 


background image

9

Please replace the cartridge.

 

Please refer to P.10 “10. Replacing the 
Cartridge”

Please open or loosen the water 
stopcock.

 

Please refer to P.6 “5. Names of Parts”

Partially shut-off the water 
stopcock

 

Please refer to P.6 “5. Names of Parts”

Contact the store, distributor, 
contractor or manufacturer 
regarding part replacement.

Allow the filtered water to flow 
while turning the cartridge 
upside down a few times so as to 
drain out air from inside the
cartridge.

Please refer to P.6 “4. Irregular Water Flow”

Reduced filtered 
water volume

The tap drips 
when turned off.

Water flow does 
not stop sharply 
when starting to 
use a new cartridge

Leakage in the 
connection 
between faucet 
and hoses

Leakage in the 
connection 
between faucet 
and hoses

Leakage in the 
faucet

No water flow

Unpleasant 
taste or odour.

Problem

Potential causes

Solution

Unsuitable 
components and 
lifespan.

Air is present in 
the cartridge.

The water 
stopcock is too 
tight or 
completely 
closed.

Unsuitable 
components and 
life span etc.

Water pressure 
is and volume 
are too high.

Cartridge is 
clogged.

If the tap continues to drip after you have 

drained air from cartridge, it is caused by 
residual water inside the cartridge and is 
not a system malfunction.

9. Troubleshooting

 


background image

10

Protective cap

Plug

Green sticker)

Grey sticker

) 

Green sticker)

Grey sticker

) 

③ 

④ 

Slide ring (green)

The connecting order should be from green to grey.

③→④ 

4

Remove the upper protective 
caps of the new cartridge (2 
pieces).

5

Connect the green and grey stickers of the 
new cartridge with the slide rings of 
matching colour, then press them together.

1

C l o s e   t h e   f a u c e t   w i t h   t h e  
lever.

Attention

Ensure that the lever is closed before replacing cartridge.

(It may cause property damage by leakage.)

 

Occasionally, the water may leak a little, so please place a towel or a 

washbasin under the cartridge.

 

(It may cause property damage by leakage.)

 

Make sure that one-touch joint is plugged in completely when replacing 

cartridge.
(It may cause property damage by leakage.)

 

(If it is connected incorrectly, it may produce blackened water (with activated 

carbon) or cause damage or leakage.)

 

Make sure there is no irregularity such as leakage from the piping or 

hoses, when replacing the cartridge.

 

(It may cause property damage by leakage.)

 

After replacing the cartridge, please run the filtered water for at least 

1 minute.

Cartridge Replacement Method

Replacement period of the cartridge

 

The replacement period will be approximately one year, but earlier replacement is recommended.

Please replace the cartridge in the following situations.

 

“Filtered water” volume has significantly decreased.

Unpleasant taste or odour.

10. Replacing the Cartridge

 


background image

11

Green sticker)

Grey sticker

) 

6

Run water by opening the lever 
handle. Ensure there are no 
leaks in the connection.

2

Pull the cartridge out towards 
yourself after removing it from the 
tray. Water may leak a little 
occasionally, so please place a 
towel or washbasin undo the 
cartridge.

3

. 

7

. 

Do not buckle or distort the hoses 
when placing into the cartridge tray.

The cartridge will rapidly become clogged up under the following conditions.

〉 

1. Water supply facilities of the 

building are contaminated.

2. Pipes in old housing are 

deteriorating.

3. Tap water becomes contaminated 

temporarily because of pipeline 
construction.

4. A newly connected pipe has not 

been properly cleaned.

5. Water pressure is noticeably low
    (high story building.)

Cartridge

One-touch joint

Slide ring

 (grey)

Plug (out)

Plug (in)

Slide ring

 (green)

Enlarged view of cartridge

(Green sticker) (Grey sticker)

Slide ring (grey)

② 

① 

Hoses

One-touch joint

To buy new cartridge, please contact the store where you bought Cleansui.
Dispose of used cartridges in accordance with local waste regulations.

Green sticker

) 

Grey sticker

) 

Pull up the slide ring (grey) with your finger, and 
then remove the one-touch joint from the 
cartridge. Remove the one-touch joint of the 
slide ring (green) with the same method.

 

The removal order should be from grey to green.

 ①→② 

Pull up this 

ring when

removing it

 


background image

12

11. After-sale Service

The Minimum Holding Period of Replacement Parts

The minimum holding period of replacement parts of this product is 10 years after production is

discontinued. The replacement parts are necessary to maintain the product's basic function, and it may be

necessary to replace them during the operational lifetime of the product.

Please note that it may be that only a substitute part is available, hence external appearance of the design or the design may differ
from the original.

Warranty

Cleansui comes with a warranty. The validity of the warranty is one year from the date of
purchase, subject to term & conditions listed on warranty. Please see the warranty for details.

Abrasion and deterioration of parts may cause leakage, so some parts need to be 
replaced.
Examples of parts which can be worn or deteriorated: check valves, rubber washers, 
shower hose and lever etc.
By replacing parts when the parts are worn or deteriorated, the basic function of the 
product can be maintained.

Parts replacement

 


background image

13

Before asking for a Service (Maintenance or Repair)

1. Refer to section “9. Troubleshooting” and verify the details of the situation.

2. Having verified the situation details, please contact the store from which you purchased your

product or the contractor who installed your water purifier.

3. When you make an inquiry, please inform them of the following points.

Product Name (Under sink water filter “Cleansui”)

Set Number (A501ZCBE)

Problems in detail

Replacement of Cartridge (Sold Separately)

1. Please contact the store or the contractor who installed the system

when you need to replace the cartridge or other parts.

2. you need to buy the cartridge, please quote specific model number:

UZC2000E

3. Do not place or store the cartridge in locations subject to high

temperatures

(locations subject to direct sunlight, inside cars that are parked in

direct sunlight, etc.) It is recommended to use the cartridge as soon as

possible after opening.

Cartridge Model Number: 

UZC2000E

 


background image

14

12. Specifications

Faucet dimensions

Faucet dimensions

Diametre of base

Height of water wateroutlet

Installation table thickness

Diametre 36

40mm

Diametre 50mm

188mm

A501 3

25mm

Specifications

Cartridge Model Number

Set Number

UZC 2000E

A501ZCB

E

Cartridge components

Polyethylene hollow fibre membrane, ion exchange fibre,

activated carbon, non woven fabric

Initial water flow rate

3 litres / min

Filtration

performance

Based on 
JIS S 3201

Free residual chlorine

Turbidity

Trihalomethanes

Chloroform

Bromodichloromethane

Dibromochloromethane

Bromoform

Soluble Lead

CAT(agrichemicals)

2-MIB (musty odour)

Tetrachloroethylene

Trichloroethylene

1,1,1-trichloroethane

40,000 litres

(80% removed)

20,000 litres

(50% filtration flow rate)

8,000 litres

(80% removed)

8,000 litres

(80% removed)

10,000 litres

(80% removed)

10,000 litres

(80% removed)

10,000 litres

(80% removed)

10,000 litres

(80% removed)

20,000 litres

(80% removed)

20,000 litres

(80% removed)

20,000 litres

(80% removed)

20,000 litres

(80% removed)

10,000 litres

(80% removed)

Substances cannot be removed

Salt (seawater) or metallic ions (except lead) contained in water

Minimum working water pressure

0.07 MPa

Dimensions of the cartridge

105mm (Maximum diameter)

×

217mm (Height)

Weight of the cartridge

(When filled with water)

800g (1400g)

Material

Cartridge

Faucet

Connecting Hose

ABS resin

Polyethylene

The estimated period of cartridge
replacement (Based on JIS S 3201)

1 year (20 litres/day) (When the filtration performances on trihalomethanes

and chloroform decline to the levels mentioned above)