background image

TempoLink Smart Assistant

Operation Manual

Temposonics

®

Magnetostrictive Linear Position Sensors

GENERA

TION

I AM

V

THE NEW

 


background image

TempoLink Smart Assistant

Operation Manual

I

 2 

I

Table of contents

1. Introduction ............................................................................................................................... 3

2.  Safety instructions ....................................................................................................................... 4

2.1 Intended use ..................................................................................................................................................................4

2.2 Foreseeable misuse........................................................................................................................................................4

2.3 Installation, commissioning and operation ....................................................................................................................5

2.4 Safety instructions for use in explosion-hazardous areas ..............................................................................................5

2.5 Warranty ........................................................................................................................................................................5

2.6 Return ............................................................................................................................................................................5

2.7 Removal .........................................................................................................................................................................5

3.  Package content ......................................................................................................................... 6

4.  Connection of TempoLink smart assistant to R-Series 

V

 sensor ................................................................. 6

5.  Connection of TempoLink smart assistant to power supply ....................................................................... 7

5.1 Using the plug-in power supply with plug adapters  ......................................................................................................7

5.2 Using the cable for insertion in an existing sensor power supply with sensor mating connector and barrel connector .7

6.  Connection of TempoLink smart assistant to smartphone, tablet or computer ................................................. 7

6.1 Connecting a Wi-Fi enabled device to the integrated Wi-Fi access point ........................................................................7

6.2 Connecting a computer via USB connection ..................................................................................................................7

7.  Establishing a connection via browser ............................................................................................... 8

8.  Graphical user interface ................................................................................................................ 8

9.  LEDs of TempoLink smart assistant ................................................................................................... 9

 


background image

TempoLink Smart Assistant

Operation Manual

I

 3 

I

1.  Introduction

1.1 Purpose and use of this manual

Before starting the operation of TempoLink smart assistant, 

read this documentation thoroughly and follow the safety 

information. Keep this manual for future reference!

The content of this technical documentation is intended 

to provide information on mounting, installation and 

commissioning by qualified automation personnel

 1

 or 

instructed service technicians who are familiar with the 

project planning and dealing with Temposonics

®

 products.

1.2 Used symbols and warnings

Warnings are intended for your personal safety and for 

avoidance of damage to the described product or connected 

devices. In this documentation, safety information and 

warnings to avoid danger that might affect the life and health 

of operating or service personnel or cause material damage 

are highlighted by the pictogram, defined below.

Symbol

Meaning

This symbol is used to point to situations 

that may lead to material damage, but not 

to personal injury.

1/ 

The term “qualified technical personnel” characterizes  

persons who

•  are familiar with the safety concepts of automation  

technology applicable  

to the particular project and

•  are competent in the field of electromagnetic compatibility 

(EMC) or

•  have received adequate training for commissioning and  

service operations or

•  and are familiar with the operation of the device and know the  

information required for correct operation provided in the 

product documentation

NOTICE

 


background image

TempoLink Smart Assistant

Operation Manual

I

 4 

I

2.1 Intended use

This product may be used only for the applications defined 

under item 1 and item 2 and only in conjunction with the 

third-party devices and components recommended or 

approved by MTS Sensors. As a prerequisite of proper 

and safe operation, the product requires correct transport, 

storage, mounting and commissioning and must be operated 

with utmost care.

 1. The sensor systems of all Temposonics

®

 series are 

intended exclu sively for measurement tasks encountered 

in industrial, commercial and laboratory applications. The 

sensors are considered as system accessories and must 

be connected to suitable evaluation electron ics, e.g. a 

PLC, IPC, indicator or other electronic control unit. 

 2. TempoLink smart assistant is an accessory for 

Temposonics R-Series 

V

 sensors for reading out and 

adjusting of sensor parameters as well as monitoring 

status values. 

2.2 Foreseeable misuse

2.  Safety instructions

Do not alter the sensor assistant.

 The sensor assistant might be damaged.

Do not step on the sensor assistant.

 The sensor assistant might be damaged.

Foreseeable misuse

Consequence

Wrong sensor connection

The sensor and TempoLink smart 
assistant will not work 
properly or can be damaged

Power supply is out of the defined 
range

The TempoLink smart assistant 
can be damaged

Cables are damaged

Short circuit – the sensor and 
TempoLink smart assistant can 
be destroyed / sensor does not 
respond

Wrong connection  
of ground / shield

Signal output is disturbed
The electronics can be damaged

 


background image

TempoLink Smart Assistant

Operation Manual

I

 5 

I

2.3 Installation, commissioning and operation

The position sensors and TempoLink smart assistant must 

be used only in technically safe conditions. To maintain 

this condition and to ensure safe operation, installation, 

connection and service, work may be performed only by 

qualified technical personnel.

If danger of injury to persons or of damage to operating 

equipment is caused by sensor failure or malfunction, 

additional safety measures such as plausibility checks, limit 

switches, EMERGENCY STOP systems, protective devices 

etc. are required. In the event of trouble, shut down the 

sensor and protect it against accidental operation. 

Safety instructions for commissioning

To maintain the sensor and TempoLink smart assistant 

operability, it is mandatory to follow the instructions given 

below.

 1. Protect the sensor and TempoLink smart assistant 

against mechanical damage during installation and 

operation.

 2. Do not open or dismantle the sensor and TempoLink 

smart assistant.

 3. Connect the sensor and TempoLink smart assistant very 

carefully and pay attention to the polarity of connections 

and power supply.

 4. Use only approved power supplies.

 5. Ensure the sensor and TempoLink smart assistant are 

operating within the defined limits for supply voltage, 

environmental conditions, etc. 

 6. Check the function of the sensor and TempoLink smart 

assistant regularly and provide documentation of the 

checks.

 7. Before system switch-on, ensure that nobody’s safety  

is jeopardized by starting machines.

2.4 Safety instructions for use in explosion-hazardous   

 areas

The sensors are not suitable for operation in explosion- 

hazardous areas. 

2.5 Warranty

MTS Sensors grants a warranty 

2

 period for the Temposonics

®

 

position sensors and supplied accessories relating to 

material defects and faults that occur despite correct use in 

accordance with the intended application. The MTS Sensors 

obligation is limited to repair or replacement of any defective 

part of the unit. No warranty can be taken for defects that are 

due to improper use or above average stress of the product, 

as well as for wear parts. Under no circumstances will MTS 

Sensors accept liability in the event of offense against the 

warranty rules, no matter if these have been assured or 

expected, even in case of fault or negligence of the company.

MTS Sensors explicitly excludes any further warranties. 

Neither the company’s representatives, agents, dealers nor 

employees are authorized to increase or change the scope of 

warranty.

2.6 Return

For diagnostic purposes, the sensor can be returned to  

MTS Sensors or a repair facility explicitly authorized by MTS 

Sensors. Any shipment cost will be borne by the sender 

2

.

2.7 Removal

The product contains electronic components and must be 

disposed of in accordance with the local regulations.

2/ 

See also applicable MTS Sensors sales and supply 

conditions, e.g. under www.mtssensors.com

 


background image

TempoLink Smart Assistant

Operation Manual

I

 6 

I

3.  Package content

4.  Connection of TempoLink smart assistant to  

 

 R-Series 

V

 sensor

The TempoLink smart assistant can be connected to all 

sensors of the R-Series 

V

 family. Use the adpater cable   for 

connection of the TempoLink smart assistant to the R-Series 

V

 

sensor. Connect the barrel connector of the adapter cable 

to the connection point labeled “OUTPUT SENSOR” on the 

TempoLink smart assistant. Next, connect the opposite end of 

the adapter cable to the power supply at the R-Series 

V

 sensor. 

The TempoLink smart assistant also provides the supply power 

for the sensor.

If the sensor is connected to another power supply 

disconnect the power supply before connecting TempoLink 

smart assistant to the sensor.

 TempoLink smart assistant

 Plug-in power supply with plug adapters or cable for  

  insertion in an existing sensor power supply  

  with sensor mating connector and barrel connector
Power supply with plug adapters

M8 male (D56)*

M12 male (D58)*

 Adapter cable for connection of TempoLink smart  

  assistant to R-Series 

V

 sensor

EM08 (Sensor – Barrel)*

EM12 (Sensor – Barrel)*

 USB cable for optional connection of TempoLink smart  

  assistant to a computer

* One of the above supplied depending on the configurated 

TempoLink kit

NOTICE

When disconnecting the power supply of the sensor 

possibly error messages occur at the connected controller. 

Fig. 1: Package content of the TempoLink kit

Fig. 2: Connection of TempoLink smart assistant to R-Series 

sensor

OUTPUT

INPUT

SENSOR

24V D

C

 


background image

TempoLink Smart Assistant

Operation Manual

I

 7 

I

NOTICE

If you are using a mobile device, ensure cellular data is off.

Depending on your operation system, message can appear, 

that there is no internet access. TempoLink smart assistant 

does not need internet access.

Connecting to the user interface may take longer if Wi-Fi 

and LAN connections are active.

5.  Connection of TempoLink smart assistant to  

      power supply

There are two ways:

5.1 Using the plug-in power supply with plug adapters 

Connect the barrel connector   to the “INPUT 24 VDC” port 

on the TempoLink smart assistant. Next, insert the plug into 

the outlet. Additional outlet adapters are supplied to support 

regional requirements.

6.  Connection of TempoLink smart assistant to  

 

  smartphone, tablet or computer

Connect to a smartphone, tablet or computer to display the 

graphical user interface of the TempoLink smart assistant.

6.1 Connecting a Wi-Fi enabled device to the  

 

integrated Wi-Fi access point 

3

 

The default password is the serial number printed on the  

label on the bottom of the TempoLink smart assistant. 

Activate Wi-Fi on the device and choose the network 

“TempoLink_xxxx” (xxxx indicates the last four digits of the 

serial number).

OUTPUT

INPUT

SENSOR

24V DC

OUTPUT

INPUT

SENSOR

24V D

C

5.2 Using the cable for insertion in an existing sensor 

 

power supply with sensor mating connector and    

 

barrel connector

Connect the supplied sensor mating connector   to your 

existing power supply connector that was removed from the 

sensor. Connect the barrel connector to the “INPUT 24 VDC” 

port on the TempoLink smart assistant.

Fig. 3: Connection of TempoLink smart assistant with the plug-in 

power supply

Fig. 4: Connection of TempoLink smart assistant with the cable for 

insertion in an existing sensor power supply cable

Fig. 5: Choose the network “TempoLink_xxxx” in the Wi-Fi 

settings of the Wi-Fi-enabled device

6.2 Connecting a computer via USB connection

The TempoLink smart assistant can also be connected via 

USB. If the computer is Wi-Fi enabled deactivate Wi-Fi on the 

computer before setting up the USB connection.

Connect the USB cable   with the micro USB connector to 

the port labeled “USB” on the TempoLink smart assistant. 

Next, connect the USB type-A connector to a free USB port of 

the computer. The USB connection simulates a network card. 

In the folder “network connections” on the computer the 

connection is shown as “IP-over-USB” or “Remote NDIS”.

3/ 

The integrated Wi-Fi access point does not provide 

internet access

 


background image

TempoLink Smart Assistant

Operation Manual

I

 8 

I

After the connection via Wi-Fi or USB is established, open the 

browser and go to the website-URL: 

http ://tempolink/

The green or red circle in the top right shows the status of 

the connection between the TempoLink smart assistant and 

the sensor.

Fig. 7: Start page of the graphical user interface

Fig. 8: Connection status

Connection status

Green

Information

ON

Connection to sensor is established

Red

Information

ON

Connection to sensor is not established

Click the menu symbol   in the top left to get to the main 

menu:

TempoLink:

 includes information about the TempoLink smart 

assistant like its serial number, firmware version and product 

number. In addition the password for the Wi-Fi access point 

can be changed.

Status:

 includes current information about the sensor status 

like

•  Position of the magnet(s)

•  Temperature inside sensor electronic housing

•  Input voltage

•  Operational time: total operational hours of the sensor

•  Odometer: total distance travelled by the position magnet

•  Magnet cycles: total number of directional changes of the 

magnet

Sensor Info:

 includes information about the connected 

sensor like stroke length, serial number and order code.  

The displayed information depends on the sensor protocol.

Parameters:

 includes information about the operational 

settings of the connected sensor. The displayed parameters 

depend on the sensor protocol and some operational settings 

may not be adjustable.

Network:

 includes information about the network settings of 

the connected sensor. The displayed information depends on 

the sensor protocol.

NOTICE

Only one device can be connected to the TempoLink smart 

assistant at a time in order to display the graphical user 

interface.

NOTICE

Disable all Wi-Fi and LAN connections before connecting 

TempoLink smart assistant via USB.

Connecting to the user interface may take longer if Wi-Fi 

and LAN connections are active.

USB connector

Fig. 6: USB port on the TempoLink smart assistant

7.  Establishing a connection via browser

8.  Graphical user interface

Fig. 9: Main menu of the graphical user interface

 


background image

TempoLink Smart Assistant

Operation Manual

I

 9 

I

Fig. 10: LED connection status

9.  LEDs of TempoLink smart assistant

Three LEDs in the lid of the TempoLink smart assistant 

display the current status of the tool:

TempoLink smart assistant LEDs

Status LEDs

LED A
Communication between TempoLink sensor assistant and sensor

LED color

Information

Green

ON

Sensor connected

Red

ON

Data transfer from TempoLink sensor assistant 

to sensor

Orange

ON

Sensor connected and data transfer from 

TempoLink sensor assistant to sensor

LED B
Communication between sensor and TempoLink sensor assistant

LED color

Information

Red

ON

TempoLink sensor assistant receives data from 

connected sensor

OFF

No sensor connected

LED C 
USB & Wi-Fi connection

LED color (up)

Information

Green

ON

USB connection exists

Red

ON

USB connection error

OFF

No USB connection

LED color (down)

Information

Green

ON

Wi-Fi activated on TempoLink sensor assistant

Red

ON

Wi-Fi error on TempoLink sensor assistant

 


background image

TempoLink Smart Assistant

Operation Manual

I

 10 

I

Notes

 


background image

TempoLink Smart Assistant

Operation Manual

I

 11 

I

Notes

 


background image

UNITED STATES

MTS Systems Corporation 

Sensors Division

3001 Sheldon Drive
Cary, N.C. 27513
Phone: +1 919 677-0100
E-mail: info.us@mtssensors.com

GERMANY

MTS Sensor Technologie

GmbH & Co. KG

Auf dem Schüffel 9
58513 Lüdenscheid
Phone: +49 2351 9587-0
E-mail: info.de@mtssensors.com

ITALY

Branch Offi ce

Phone: +39 030 988 3819
E-mail: info.it@mtssensors.com

FRANCE

Branch Offi ce

Phone: +33 1 58 4390-28
E-mail: info.fr@mtssensors.com

GREAT BRITAIN 

Branch Offi ce

Phone: +44 79 44 15 03 00
E-mail: info.uk@mtssensors.com

CHINA

Branch Offi ce

Phone: +86 21 6485 5800 
E-mail: info.cn@mtssensors.com

JAPAN

Branch Offi ce

Phone: +81 3 6416 1063
E-mail: info.jp@mtssensors.com

www.mtssensors.com

MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States; MTS SENSORS and the MTS SENSORS logo are trademarks of MTS Systems Corporation within the 

United States. These trademarks may be protected in other countries. All other trademarks are the property of their respective owners. Copyright © 2018 MTS Systems Corporation. No license of any intellectual 

property rights is granted. MTS reserves the right to change the information within this document, change product designs, or withdraw products from availability for purchase without notice. Typographic and 

graphics errors or omissions are unintentional and subject to correction. Visit www.mtssensors.com for the latest product information.

Document Part Number: 

551986 Revision B (EN) 10/2018