PDF User Manual

  1. Home
  2. Manuals
  3. Dimplex FTE10 Installation And Operating Instructions Manual

Dimplex FTE10 Installation And Operating Instructions Manual

FTE16 FTE20

Made by: Dimplex
Type: Installation And Operating Instructions
Category: Dehumidifier
Pages: 12
Size: 0.38 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

   

Installation and

 

Operating Instructions 

Model:    FTE10        10L        Dehumidifier 

Model:    FTE16        16L        Dehumidifier 

Model:    FTE20        20L        Dehumidifier         

08/52826/0 Issue 0

 

   

 

   

 

 

 

 

_________________________________________________________________________________________________________________________________________________ 

 

Products comply with the European Safety Standard EN60335-2-40 and the relevant parts of the European Standards for Electromagnetic Compatibility (EMC) EN55014, and 

EN61000 along with EN62233 covering Electromagnetic Field (EMF) requirements. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC.           

_________________________________________________________________________________________________________________________________________________

 


background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

 
SAFETY INFORMATION 
 

1. 

Please read the operating instructions carefully before using your 
dehumidifier for the first time and keep them in a safe place. 

2. 

Never immerse the appliance in water or other liquids. 

3. 

Never operate the appliance if a cable or connector has been damaged, 
after appliance malfunction or if the appliance was dropped or is 
otherwise damaged. 

4. 

Please ask a professional service agent to repair the product. Improper 
repair may cause danger to users. 

5. 

Never allow children to operate the appliance. 

6. 

Disconnect the appliance from mains power whenever it is not in use, 
before relocating it, and before cleaning. 

7. 

Operate the appliance only at the voltage specified on the rating label. 

8. 

This appliance is designed for household purposes (not commercial) 
only. 

9. 

DO NOT COVER. 

Never cover or obstruct in any way the outlet at the 

top of the dehumidifier or the air inlet slots at the rear of the 
dehumidifier.   

10.  To prevent spillage, empty the water tank before relocating the 

appliance. 

11.  Do not tip the appliance to any side as escaping water could damage 

the appliance. Only operate the product in a level upright position.             

12.  This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not 
play with the appliance. 

13.  When the supply cord is damaged, it must be replaced by the 

manufacturer, or a professional service agent only. 

14.  Only operate this appliance with a minimum of 50cm clearance all 

around i.e. away from walls, furniture and overhanging objects such as 
curtains or a shelf. 

15. 

When the unit stops, you have to wait for 3 minutes before you can 
restart the unit to protect the compressor from damage

   

 


background image

 
 
OPERATING INSTRUCTIONS 
 

1. 

Control panel                                           

2. 

Air outlet 

3. 

Carry handle   

4. 

Front panel 

 

 

 

 

 

5. 

Air inlet 

6. 

Water outlet tube 

(continuous use) 

7. 

Water tank 

 

 

 

 

 

 

 

 

 


background image

CONTROL PLATE DESCRIPTION 

 

OPERATION INSTRUCTION   

Starting the unit   

Allow the unit to stand upright for 24hrs to let the compressor stabilize 

before first use or when transported. 

1. Firstly, turn the humidity control switch to the “OFF” position. 

2. Plug in the dehumidifier. 

3. Turn on the humidity control switch (clockwise) and set it at the desired 

humidity level, please refer to table in point 4 below (e.g. position”4 = 60%). 

4. For assistance in drying clothes in a laundry/ utility room, please select 

maximum dial position for continuous operation and maximum moisture 

removal.   

 
Turning off the unit   

1. Turn the humidity control switch fully anticlockwise to the “OFF” position 

and the power supply is cut off and the unit stops operating. 

2. If the dehumidifier is not in use for a long time, please disconnect the power 

cord plug from the supply outlet.

 

 
NOTES AND PRECAUTIONS 

1. The dehumidifier will not operate if the humidity dial is set lower than the 

ambient humidity e.g. room humidity 40% and dial setting 2 or 4. In other 
words the higher the humidistat dial setting e.g. position 8 the dehumidifier 
will attempt to dry the ambient humidity to 20% (RH) relative humidity.       

2. When the water tank is full an automatic float switch shuts down the 

product and the tank full LED illuminates. Remove the water storage tank 
and empty its contents, carefully replace the empty water tank back in 
position, the unit will now automatically restart operating. 

 


background image

3. The following table indicates the approximate relative humidity settings 

against its related position number on the humidity control switch: 

 

CONTROL SWITCH 

POSITION NO. 

APPROXIMATE 

HUMIDITY SETTING 

Cont.

 

 

Continuous 

running 

20

 

30

 

40

 

60

 

80

 

4. 

The ideal position is around position 6- approximately 40% relative 
humidity 

5. 

The operational temperature range for this unit is 5-35°C. Please note the 
effectiveness of the product reduces as the ambient temperature reduces.   
For example in a room of 6

o

C- little if any moisture will be removed. The 

product works on the principal that it requires a high ambient temperature 
with warm air drawing over a very cold compressor creating water 
droplets. 

6. 

Other than on the case of note 2 above, where the dehumidifier does not 
start, the operational light does not illuminate or the dehumidifier 
intermittently stops for unknown reasons, please check the plug and 
power supply for poor connection. If the plug and power supply are in 
good condition, wait for 10 minutes and restart the unit (it can take about 
10 minutes for the unit to reset). If the unit still does not start after 10 
minutes, please contact your retailer or the manufacturer for repair. 

7. 

When the dehumidifier is in operation, the running compressor will 
produce heat. This is normal and may potentially raise the room 
temperature. 

8. 

When the product is defrosting, the defrost LED will illuminate. The 
reason this happens is because the compressor gets very cold to 
maximize moisture removal. The defrost function protects the compressor 
from freezing up and avoid damage to the product. 

 


background image

DRAINAGE INSTRUCTION 

  Switch off before carrying out any of these 

operations and leave for 3 minutes before switching 
on again. The extracted water is collected by the 
water tank (set up as supplied), or can be set up to 
drain continuously using a PVC hose (not included) 
connected to a drain    outlet, the drain point must 
be lower than the unit outlet (see details below). 

 

USE OF WATER TANK: 

            When the tank full LED illuminates the tank is full, the compressor and the 

fan will stop operation, please empty the water tank. Remove the water tank 
as per Fig 01 and empty it. Gently refit the water tank into the unit in its 
original position. Note, if the tank full LED remains on when the tank is 
emptied please remove and re-fit the tank to reset the light.   

 

CONTINUOUS DRAINAGE 

          If you want to use this function, please pull out the water tank and plug a 9mm 

internal diameter water pipe onto the “Water out 
tube” (See Fig.02). Replace the water tank into the 
unit, the unit will now operate while discharging the 
extracted water through the free end of the fitted 
pipe, Note, you must ensure that the free end of the 
pipe is below the product outlet connection and that 
the drain point is likewise lower than the unit outlet. 

 

Filter Removal 

           

To remove the filter you must first remove the 

water tank as instructed above.

 

The filter can then be removed from its slot by 
gripping the filter handle and sliding it down 
and out of the back of the appliance as 
indicated below. 

• Every 2 weeks, remove the filter and clean it 

with warm water, below 40°C. Allow it to dry 
naturally and then replace by reversing the removal instruction above. 

Fig 02

 

Fig 01

 

 


background image

 
Care and Maintenance Instruction 

1. 

To avoid the occurrence of vibration and noise the unit should not be 
operated while located on any soft or uneven surface.   
 

2. 

Never insert any foreign objects into the unit through its air inlet or outlet 
to avoid hazard or unit failure.     
 

3. 

During power off or when not in use for a long time, please disconnect 
the product from the mains. 

 

 

 

 

 

 

4.  For a better dehumidifying effect, the areas to the front, rear and above 

the unit should be clear and free from any obstacles which will block the 

air flow of the unit. Do not block any air inlet or outlet grilles – keep clear 

of hanging drapes, curtains and furnishings – 

DO NOT COVER, as 

specified under safety information section a clearance of 50cm 

should be maintained all around the appliance when it is in use.

   

     

5.    Every 2 weeks, remove the air filter and clean it with warm water, below 

40°C. Allow it to dry naturally and then replace by reversing the removal 

instruction above.     

 

 

 

 

 

 


background image

SPECIFICATIONS 

 

                          MODEL 

SPECIFICATION                 

FTE10 

FTE16 

FTE20 

POWER SUPPLY 

220-240V~50Hz 

POWER INPUT 

250W 

410W 

480W 

RUNNING CURRENT 

1.2A 

2.1A 

2.2A 

WEIGHT 

11.1Kg 

13.3Kg 

13.7Kg 

MOISTURE REMOVAL     

(@ 30

& RH 80%

 

10 litre/day   

16 litre/day 

20 litre/day 

DIMEMSIONS 

(WxDxH)mm 

W:365 x D:220 x H:500 

APPLICABLE 

TEMPERATURE 

5

 - 35

 

WATER TANK CAPACITY 

2.3L 

 

(CE) N 842/2006: 

R134A is a kind of fluorinated greenhouse gas covered by 

the Kyoto Protocol. 

Its total global warming potential (GWP) is 1300 

 

 

 

 

 

Recycling:

 For electrical products sold within the European 

Community.    At the end of the electrical products useful life it 
should not be disposed of with household waste.   
Please recycle where facilities exist. 
Check with your Local Authority or retailer for recycling advice in 
your country. 

 


background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

After Sales Service: 

Your product is guaranteed for one year from the date of purchase. Within this 
period, we undertake to repair or exchange this product free of charge 
provided it has been installed and operated in accordance with these 
instructions. 
 
Your rights under this guarantee are additional to your statutory rights, which 
in turn are not affected by this guarantee. Should you require after sales 
information or assistance with this product please go to www.dimplex.co.uk or 
ring our helpdesk on 0844 879 3588 (UK) or 01 842 4833 (R.O.I.). 
 
It would assist us if you can quote the model number, series, date of purchase 
and the nature of the fault at the time of your call. The customer services 
helpdesk will also be able to advice you should need to purchase any spares. 
 
Please do not return any faulty product to us in the first instance as this may 
result in loss or damage and delay in providing you with a satisfactory service. 
Please retain your receipt as proof of purchase.   

____________________________________________________________ 
 

CE 

This appliance complies with European Safety Standard EN60335-2-40, and 

European Electromagnetic Capability (EMC) EN55014-1, EN55014-2, EN61000-
3-2 and EN61000-3-3. These cover the essential requirements of EEC Directives 
2006/95/EC and 2004/108/EC.

   

 
Dimplex   

 

 

Customer Service UK:  0844 879 3588 

Millbrook House 

 

Fax:  

 

 

 

0844 879 3582

 

Grange Drive   

 

Email: customer.service@gdcgroup.co.uk 

Hedge End 

 

 

Republic of Ireland:  

01 842 4833 

Southampton 
S030 2DF 
 
A division of GDC Group Ltd. 
Website: www.gdcgroup.co.uk 

 

© GDC Group Ltd. 
All rights reserved. Material contained in this publication may not be reproduced in whole 
or in part without prior permission in writing of GDC Group Ltd.

     

 
 
 
 
 
 
 

 


background image