12 LITRE DEHUMIDIFIER 

INSTRUCTION MANUAL 

     

 

                 

 

 


background image

 

 

Thank you for selecting super quality dehumidifier. Please be sure to read this manual 
carefully before using it. Keep the manual for future reference.

 

SAFETY INSTRUCTIONS                                     

Please read the operating instructions carefully before using your dehumidifier for the first 

time. 

1.  Install the appliance on flat and hard place to avoid occurrence of vibration   and 

noise. 

2.  Never immerse the appliance in water or other liquids. 

3.  Never operate the appliance if the cable or connector is damaged, or there is 

something abnormal may happen. 

4.  Disconnect the appliance from power supply when it is not in use, or before relocating 

or cleaning it. 

5.  Operate the appliance only at the voltage specified. 

6.  The appliance is for indoor use only, do not use it for other purpose. 

7.  Do not put heavy objects on the appliance. 

8.  Do not cover the unit. 

9. To 

prevent 

spilling, 

empty the water tank before restarting the appliance. 

10. Do not put the unit close to heat-generating devices or near flammable and dangerous 

materials, don’t tip the appliance to any side as spilt water could damage the appliance. 

11. Never insert any slim rod and hard object into the unit body to avoid occurrence of 

hazard or unit failure.   

12. Always store the unit upright in order to maintain the compressor in a proper working 

condition. Leave the unit upright for at least 24 hours before operating. 

13. This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless they 

have been given supervision or instruction concerning use of the appliance by a person 

responsible for their safety. Children should be supervised to ensure that they do not play 

with the appliance. 

 


background image

 

 

 

Don’t try to repair, dismantle or remold such appliance, or it may make some damage. 

Even if the supply cord is damaged, it must be replaced by the manufacturer or its service 
agent or a similarly qualified person in order to avoid a hazard.   

 

PLACEMENT                                                                                     

 

When positioning the dehumidifier, ensure that it is placed on a level surface and that there 
is a minimum of 10cm of space on either side of the unit to allow for efficient airflow. 
 
We do not recommend the use of an extension lead, so please try to ensure that the unit is 
sufficiently close to a fixed main socket. If it is necessary to use an extension lead, please 
ensure the diameter of the wires of the cable is at least 1 mm

2

 
When the dehumidifier is in operation, outside doors and windows should be closed when 
necessary for most efficient use. 
 
Make sure that there is no obstruction around the air inlet and the air outlet. The position of 
the air inlet and outlet is as below: 

 

       
       

                                   

 
 

             

Air inlet 

Air outlet 

 


background image

 

 

KNOW YOUR APPLIANCE                                    

MAIN UNIT 

CONTROL PANEL                   

 
 
(1) ON/OFF button 
(2) Full water indicator 
 
 
 
 

Operation 

 

-  Plug the unit into a correct mains socket. 
-  Press the “ON/OFF” button once. The unit will start to work and the power indicator 

light will illuminate. 

-  Press the “ON/OFF” button again. The unit will stop and the power indicator light will 

go off. 

Note

 

1. Do not use the machine when the temperature is 

over 35

 or below 5

.

 

2. When the unit has been turned off, please wait for at least 5 minutes before turn it on 

again. Fails to do this will damage the compressor. 

3. This unit is fitted with an auto defrosting function. It will start when the evaporator 

generates frost. This function will start to running when the temperature goes down to 5

.  

 
 
 

 

 


background image

 

 

DRAINAGE                                            

While the water tank is full, the compressor will stop and the water full indicator light will 
illuminate. 
To remove the water tank, pull it out carefully from the unit. 
After empting the water tank, place the tank back to the unit. Make sure it is properly 
positioned, in order for the water full indicator light to go out and your dehumidifier is 
operating. 
Please note, in case, the water tank has not been positioned well, the water full indicator 
light will still illuminate. 

 

 

 

CONTINUOUS DRAINAGE                               

When the dehumidifier is operated at very high humidity levels, the water tank will require 
more frequent drainage. In this situation, it may be more convenient to set the unit up for 
continuous drainage with the following procedures: 
 
1. Remove the water tank from the unit. 
2. Remove the rubber water stopper in the continuous drainage port. Keep the rubber 
water stopper in a safety place for future use. 
3. Remove the plastic cover carefully at the back of the unit.   
4. Prepare the water tube (not included) with 

13.5

mm internal diameter and 

1.5

mm 

thickness. 
5. Insert the tube through the hole at the back to the front. 
6. Connect the tube to the continuous drainage port. 
7. Put the water tank back to the unit. 
8. Ensure the water will always drain away freely and the tube will remain in right place & 
the water tank is in correct position. 

NOTE :

 In very cold weather conditions, precaution should be taken to prevent the water 

tube from freezing. 
 
If it is no longer to use the continuous drainage, please follow the below procedures : 
1. Remove the water tank from the unit.   
2. Remove the water tube from the continuous drainage port. Then pull it out from the 
hole at the back of the unit. 

 


background image

 

 

3. Insert the rubber water stopper to the continuous drainage port. 
4. Put the water tank back to the unit. 
 
 
 

 

 

              

                                   

 

              

 

 

 

 

Continuous drainage hole 

Water tube 

Rubber water stopper 

Remove the plastic cover and insert 

the water tube through the hole.   

 


background image

 

 

CLEANING                                                                           

                   

Always unplug the unit from the power supply before beginning cleaning to avoid 

electric shocks. 

 

Housing 

- Use a soft, damp cloth to wipe the cabinet clean. Never use strong chemicals, oil-based 

products, detergents, chemically treated cloths or other cleaning solution. These could 

damage the cabinet. 

Filter 

- It is recommended to clean the air filter once every two weeks. 

-Remove the water tank and extract the filter holder.                   

-Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filter. 

Rinse the filter frame thoroughly under running water.(Do not warmer than 40

). 

- Dry thoroughly before replacing. 

- Do not expose the filter to sunlight.   

     

   

 

 

WARNING: Never operate the dehumidifier without the filters. 
 

Put back the filter carefully 
after cleaning.

 

Remove the filter on 
the side carefully.

 

 


background image

 

 

STORAGE                                                                                       

If not use the unit for an extended period of time. Please: 

-  Turn the unit off and unplug it from the mains. 
-  Completely empty the water tank and wipe it clean. 
-  Cover the unit and store where it will not receive direct sunlight. 

TROUBLE SHOOTING                                       

Never try to repair or dismantle the dehumidifier yourself. Incompetent repairs result in loss 
of warranty and can endanger the user and the property. 
             

Problem Possible 

Cause Solution 

Has the power cord 
been 
disconnected

 

Plug the power cord into 
the outlet. 

Is the tank full 
indication blinking? 
(the tank is full or in 
a wrong position) 

Empty the water in the 
drainage tank and then 
reposition the tank. 

The unit doesn't operate

 

Is the temperature 
of the room above 

5

 or below 

35

The protection device is 
activated and the unit 
cannot be started. 

Is the air filter 
clogged? 

Clean the air filter as 
instructions. 

The dehumidifying 
function doesn't work 

Is the intake duct or 
discharge duct 
obstructed? 

Remove the obstruction 
from the discharge duct 
or intake duct. 

No air is discharged 

Is the air filter 
clogged? 

Clean the air filter as 
instructions. 

Is the unit tilted or 
unsteady? 

Move the unit to a 
stable, sturdy location. 

Operation is noisy 

Is the air filter 
clogged? 

Clean the air filter as 
instructions. 

 

 

 

 

 


background image

 

 

TECHNICAL    DATA                                                                     

 

Model MDF-12DMN3 

Mains  

220V-240V 

~50Hz 

Power W 

260W 

Ampere consumption 

1.4 A 

Dehumidification capacity 
(30

 RH 80%) 

L/24h 10 

L/24h 

Dehumidification capacity 
(32

 RH 90%) 

L/24h 

13

 L/24h 

Air volume(max) 

m³/h 

120

 m³/h 

Refrigerant load 

R134a/130 g 

Compressor  

TATUNG FE140Y-E 

Recommended room size 

m

2

 Up 

to 

20

 m

2

 

Water tank 

                                     

3

 L 

Dimensions(W*H*D) mm 

315*505*235mm 

Weight Kg 

15.5Kg 

 

 
 

 
WASTE ELECTRICAL PRODUCTS SHOULD NOT BE DISPOSED OF WITH 
HOUSEHOLD WASTE.PLEASE RECYCLE WHERE FACILITIES EXIST CHECK 
WITH YOUR LOCAL AUTHORITY FOR RECYCLING ADVICE. 

 