PDF User Manual

  1. Home
  2. Manuals
  3. ph Miracle Watermark User Manual

ph Miracle Watermark User Manual

Made by: ph Miracle
Type: User Guide
Category: Water Filtration Systems
Pages: 15
Size: 2.63 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

1

The pH Miracle

®

 WaterMark

 

User’s Guide

Congratulations on your purchase of the pH Miracle WaterMark. You will now be able to enjoy 

the benefits of drinking water with high levels of antioxidants, free hydroxyl ions, increased pH 

as well as an excellent source of magnesium and other alkalizing minerals. 

Please take the time to thoroughly read this Users Guide for installation and usage instructions. 

Failure to read this guide and comply with instructions could void your warranty.

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

2

Congratulations on your purchase of the pH Miracle Water Mark perfect water generator. 

Please take the time to thoroughly read this users guide for installation and usage instructions. 

Failure to read this guide and comply with instructions could void your warranty.

TABLE OF CONTENTS:

Section #1 — Important Safety Precautions (Page 2)

Section #2 — In the Box: Verifying Parts Received (Page 3)

Section #3 — Countertop Installation (Pages 4-5)

Section #4 — Under-Sink Installation (Pages 6-9)

Section #5 — Troubleshooting and Warranty (Pages 10-12)

Section #6 — Usage Instructions (Page 13)

Section #7 — Maintenance and Filter Changes (Pages 14-15)

Section #1: Important Safety Precautions

•  Do not allow water pressure to exceed 60 psi. This may cause internal parts to leak or break, 

causing damage that cannot be repaired.

•  Do not use hot water. The use of hot water will cause damage to the machine and filters and 

will void the warranty.

•  The use of filters other than those from pH Miracle can cause defects and damage to the unit as 

well as not providing proper water.

•  This unit was designed to be used with cold tap water. Using other water sources or hot water 

could result in damage to the unit and a final product that does not meet pH Miracle’s safety rec-

ommendations.  

                   

•  Avoid areas that have:  open flames or high temperatures, excessive moisture or dust, and expo-

sure to freezing temperatures.

•  Select an area that is stable and level.

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

3

Section #2: In the Box

Please start by removing the WaterMark from its box. Inside the box should include the 

following parts:

• 

WaterMark

• 

Faucet Spout with 2 rubber ‘O’ Rings Installed at Base

• 

¼” Tubing

• 

Faucet Diverter * (chrome metal piece)

• 

Faucet Diverter Adapter Rings

• 

Faucet Gaskets/Seals (black, blue,  or green rubber ‘O’ rings)

• 

pH Test Drops with Color Chart

• 

900 Quick  Connect Stem Elbow (white plastic piece)

• 

Quick Connect Release Tool

• 

Filter Wrench (housed within the appliance)

• 

User Manual

*There  are  many  types  of  fau-

cets and it is not possible to in-

clude a faucet diverter to fit all 

faucets.    If  the  diverter  that  is 

included in the box does not fit 

your faucet please contact us by 

phone for the correct part.

**  The  WaterMark  comes  with 

the  parts  needed  to  install  the 

unit on the countertop, for un-

der-sink  installations  you  will 

need an additional parts kit that 

can be ordered by phone or on 

the  WaterMark  page  on  www.
phmiracleliving.com

If you are missing any parts, please contact the pH Miracle Center at 760-751-8321.

¼” Tubing

Faucet Spout

Faucet Diverter

Stem Elbow

Gaskets/Seals

Quick Connect 

Release Tool

pH Test Drops
     Color Chart

Adapter Rings

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

4

Section #3: Countertop Installation

Tools Needed:

• Pliers

• Scissors or Utility Knife

• Standard screwdriver

• Towel

1. Find the Water “Inlet” marked on rear of the WaterMark. Connect the Stem Elbow to the WaterMark 

by placing the smallest end into the Water Inlet and pushing until well seated. Make sure that the sec-

ond hole in the back of the WaterMark labeled as “Outlet” is covered with a plug.

2. Unwind the tubing. Firmly push one end of the tube into the large end of the Stem Elbow until 

seated. Do not push tubing so firmly that it bends; bending will cause tubing to crimp.

(If you need to remove the tube, here is a note about Quick Connect Fittings: to remove the 

tube from a Quick Connect, water supply must be off and pressure must be relieved from the 

WaterMark. You will see a round collar to the outside of the Quick Connect Fitting, this collar 

must be pushed in towards the connector and held in as you pull the tubing out. You may use 

your fingernail or the Quick Connect Release Tool to push in on the collar. If the collar is not 

pressed and held in while pulling on the tubing, the tubing will not be removable.)

3.  Remove the aerator (tip of faucet) currently attached to your faucet by turning it counterclockwise. 

Most faucets will need a tool to do this, common pliers should work. To avoid scratching your faucet, 

use a small towel to wrap around the faucet tip before using the pliers to turn it. If you cannot remove 

the faucet tip then you may want to call a handyman to help.

4. Now look at the aerator/faucet tip. Does it have threads on the outside or inside? If outside (a male 

end), follow the ‘A’ instructions below. If the threads are on the inside (a female end), follow the ‘B’ 

instructions below: 

 

A

- Locate the Adapter Rings and determine which fits your faucet—which is the same size as you 

aerator/faucet tip. Once you’ve identified the right Adapter for your faucet, verify the rubber ‘O’ ring 

is placed in the top of the Diverter, then screw the adapter onto the Diverter. Now place a rubber ‘O’ 

ring in the top of the adapter to prevent any leaks. Screw the Adapter (attached to the Diverter) into 

faucet hand tight, no need for tools. (After the final step, if you see a leak then you may use pliers to 

turn the Diverter one more half turn until leaking stops.)

B

- Make sure there is no threaded Adapter Ring on top of the faucet Diverter; if there is one, remove 

by unscrewing it. Once this piece is removed verify there is a rubber ‘O’ ring inside the top of the 

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

5

faucet Diverter, this will prevent leaks. Screw the Diverter onto the faucet hand tight, no need to use 

tools. (After the final step, if you see a leak then you may use pliers to turn the Diverter one more 

half turn until leak stops.)

5. Place the WaterMark on the level surface where you intend for it to stay. Decide how long the tubing 

needs to be to easily reach from the faucet to your WaterMark.  You may gather the tubing and hide it 

behind the WaterMark or cut the tubing to desired length using scissors or a utility knife. Do not cut the 

tubing at an angle. Also be sure to leave enough tubing to allow you to easily swivel your faucet either 

direction once attached.

6. Take the free end of the tubing and press it onto the barbed end of the faucet Diverter. Be sure to 

push the tubing completely over the barbs.    

If there is no barbed end but a nut instead, remove the nut on the Diverter. Slip the nut over the end of 

the tube and push that end onto the Diverter, over the barb revealed once you removed the nut. When 

the tube is well seated, screw the nut back on to hold it in place.

7. Now install the Faucet Spout. Verify that the two rubber ‘O’ rings are on the bottom of the shaft. Use 

olive or cooking oil to lightly coat the ‘O’ rings, then press the Spout firmly into the open hole on the 

WaterMark until the both ‘O’ rings are concealed.

8. Notice the lever on the side of the Diverter. When the lever is down the water will flow through the 

Diverter into your sink. When the lever is turned up, the water is redirected to run through your Water-

Mark. 

Turn on the water at your main faucet. Move the lever on the Diverter up to send the water through 

the WaterMark. It may take a few seconds for the water to exit the WaterMark, this is normal as all the 

filters fill with water.

9. On first use, allow the water to run through the WaterMark for at least ten minutes to flush the filters 

out (the water may appear discolored in the beginning). After the 10 minutes passes the water is ready 

for drinking.

CONGRATULATIONS, 

YOU HAVE SUCCESSFULLY INSTALLED YOUR WATERMARK.

10. Go to Section #6 for Usage Instructions. Refer to Section #5 for Troubleshooting if you have any 

problems or if the unit is not working correctly.

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

6

Section #4: Under-Sink Installation (Kit Part List)

1 ⅜” Hole Flange

½” Cold Water Supply Diverter

with Reducer & Quick Connect

⅜”  Cold Water Supply Diverter  

    with Quick Connect

Faucet Collar

Faucet Accessory Kit

Gooseneck Accessory

Faucet

 


background image

pH MIRACLE

THE

®

aterMark

W

aterMark

W

TM

7

Section #4: Under-Sink Installation (Continued)

This installation method requires a hole in the sink or counter to mount an accessory faucet. If you do 

not have an existing hole to use you will need to drill a hole. The hole needs to be at least  ¾ inch to no 

more than 1-⅜ inch in size.

Under-sink installation means the WaterMark will be under constant water pressure. Be sure your home 

is in compliance with the National Plumbing Code and the water pressure does not exceed 60psi. Install-

ing the WaterMark in a home with high water pressure can result in leaks or a blown connection.  The pH 

MIRACLE CENTER IS NOT LIABLE FOR UNDER-COUNTER LEAKS. If unsure of your water pressure, contact a 

plumber or handyman to verify your pressure is within legal limits. If your pressure is over 60psi, contact 

technical support to order a regulator. All under-sink water filters have several connections where leaks 

can occur. For the first week after installation, check for leaks daily. If you plan to be gone for more than 

one day, it is recommended that you turn off the main water supply under the sink. 

The WaterMark rarely leaks; however, for peace of mind, we do offer a product called the Leak Control-

ler that senses water leaks and will shut off the water supply to prevent water damage. For those with 

wooden kitchen floors or a higher-level kitchen this may be a good investment. Contact technical support 

to order the Leak Controller (Price: $49.95). 

 

Tools Needed:

• Pliers

• Scissors or Utility Knife

• Towel

• Possibly a 1 ⅜” hole saw with drill

1. Be sure you have ordered and received the “Under The Counter Kit” before attempting an under-

the-sink install of the WaterMark. The needed parts kit for this install is not included and must be 

ordered via phone or website: 

The Kit Includes: Accessory Gooseneck Faucet, Water Supply Diverter for both ½ and ⅜ inch 

threads, Faucet Collar, Hole Flange, and Accessory Kit. (

Image shown on previous page

.) 

2. Unpack your WaterMark and Under the Counter Installation Kit.

3. Locate cold water shut off valve under sink, this is usually the valve to the right and the hot water 

valve will be the one to the left. Sometimes plumbers reverse this so when you locate the shut off 

valve on the right, shut it off, then test it by turning on your faucet—no cold water should come out. 

If cold water is coming out then switch by turning of the other valve under the sink. Again be sure 

the valve you have shut off is the cold supply. 

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

8

(Some homes have very old and even rusty cold water shut off valves; in this case it may be nec

-

essary to install a new cold water shut off valve to assure a leak proof installation; this should 

be done by a licensed plumber if you are not able. The pH Miracle is not liable for poor quality 

installs using old unstable parts.)

 

4. Now take your pliers and loosen the nut on top of the cold shut off valve, this is where the hose 

from the faucet above is attached to the valve, unscrew with a counter clockwise motion. Unscrew 

and move the hose to the side.

5. Locate the white plastic Quick Connect Water Supply Diverter, there should be two sizes one is 

for ½ inch thread and the other is for ⅜ inch thread. Locate the piece that fits onto your cold water 

shut off valve, the piece should screw on easily, do not force it, hand tighten only. It isn’t necessary 

to use tools to install this piece. If the part is leaking after install then try to snug a little tighter by 

hand until leak stops.

6. Now re-connect the main faucet hose to the new plastic water supply fitting, use pliers to tighten 

just more than hand tight. Do not over tighten.

7. Take one end of the plastic tubing and insert it into the plastic faucet supply piece you just in-

stalled, be sure to push tubing all the way in. You may choose to cut the plastic tube to the appro-

priate length or gather the extra tube under the sink. If you cut it, be sure it’s long enough to reach 

the WaterMark where it will sit under the sink. Do nothing with the other end of the tube for now.

8. Locate Accessory Faucet and install at hole on sink or counter top. Use the instructions printed 

on the Accessory Faucet box to install the faucet. The Accessory Faucet comes as four parts: 1) Main 

spout, 2) Body, 3) Base collar, and 4) Accessory Kit which includes washers and nuts. (See labeled 

image of contents on page 6.) 

Once the Accessory Faucet is installed, then you will need to connect the plastic tubing to the bot-

tom of the faucet shaft. Use directions on back of faucet box to connect tubing.

At this point you should have 2 tubes with 2 loose ends, one coming from the cold water shut off 

valve, the other coming from the new accessory faucet shaft under the sink. 

9. Position the WaterMark under the sink where it will stay, and connect the end of the plastic tube 

coming from the cold water shut off valve into the ‘Inlet” connector on the back of the WaterMark; 

be sure to push in the tube all the way.

10. Connect the tube from the Accessory Faucet shaft to the “Outlet” connector on back of Wa-

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

9

terMark. Be sure to push in the tube all the way. Also be sure any cut ends of the tubing are cut 

square and not flattened. If fitting leaks once water is turned on then remove tubing, re-cut end 

and re-insert.

11. The under sink installation of the WaterMark is now complete. Before turning on the water 

supply, make sure the faucet on the WaterMark and the Accessory Faucet are in the off position—

handle pointing up.

12. Now turn on the water supply at the cold water shut off valve. At this time, if any water is com-

ing from either the WaterMark faucet or the new accessory faucet turn them off. Dry any water that 

has leaked or splashed. Inspect all connections for leaks, if unsure about a possible leak, dry the 

area with a paper towel and inspect again.

13. If you see any leaks shut off the water supply at the cold water shut off valve.

Open Accessory Faucet to relieve any pressure in the unit. Remove leaking tube and inspect end is 

cut square and not at an angle. If cut at an angle, re-cut it square and be sure the end is round when 

inserting tube into connector.

(If you need to remove the tube, here is a note about Quick Connect Fittings: to remove the 

tube from a Quick Connect, water supply must be off and pressure must be relieved from 

the WaterMark. You will see a round collar to the outside of the Quick Connect Fitting, this 

collar must be pushed in towards the connector and held in as you pull the tubing out. You 

may use your fingernail or the Quick Connect Release Tool to push in on the collar. If the col-

lar is not pressed and held in while pulling on the tubing, the tubing will not be removable.)

14. Once you confirm there are no leaks on the back of WaterMark and at the Accessory Faucet 

connection where tube enters faucet, then you may open the Accessory Faucet above the sink and 

let water run through the WaterMark. 

15. On first use, allow the water to run through the WaterMark for at least ten minutes to flush 

the filters out (the water may appear discolored in the beginning). After the 10 minutes passes the 

water is ready for drinking.

16. Ensure that the faucet on the actual WaterMark appliance stays closed or water will be dis-

pensed below your sink. You may want to tape the handle of the WaterMark faucet closed so it 

cannot be opened accidentally. 

17. Go to Section #6 for Usage Instructions. Refer to Section #5 for Troubleshooting if you have any 

problems or if the unit is not working correctly.

 


background image

pH MIRACLE

THE

®

aterMark

W

aterMark

W

TM

10

Section #5: Troubleshooting and Warranty

In this section we will cover most potential issues with the WaterMark installation and usage. If this sec-

tion does not cover your issue then please call us at the pH Miracle technical support line 

(949) 215-2330

 

(this number is for tech support only). 

For parts or customer service needs, please call 

(760) 751-8321

.

Question

: My WaterMark will not release water.  What should I do?

Answer

: Be sure the main water supply is on and is sending water to the unit.  Do this by removing the tube 

from the inlet valve and turn water on.  Does water come out of the tube?  If yes, then water is getting to the 

unit.  If no, check for bent tubes and ensure the Diverter is in the correct position.  If water is getting to unit 

and faucet is fully open then it is possible one of the filters is blocked and needs to be replaced. In this case, 

please call customer service to request a replacement filter.

Question

: Why is the water coming from my WaterMark so slow?

Answer

: The normal flow rate should be about 1-2 liters per minute. This may seem slow, but keep in mind 

the water is going through 5 cartridges before coming out.  If the unit is producing less than 1 liter per min-

ute, try loosening the screw on the bottom of the unit. Use a large standard flat head screwdriver to prevent 

stripping the fitting. Turn ½ a turn clockwise and retest. Repeat this process until desired flow is obtained. If 

this does not work then you may have a blocked or partially blocked filter that will need to be replaced. To 

request a replacement filter please call customer service.

Question

:  Why is the pH of the WaterMark water the same as the tap water?

Answer

:  Most tap water in the U.S. and other countries is alkaline. When testing the pH use the supplied 

drops in 1 ounce of water. Add 2-3 drops of reagent and mix well.  Your tap water will read green or blue, 

mostly blue.  If the WaterMark water is also blue, this is normal.  A blue can range from 8.5 to 9.5. The tap 

water blue may be 8.5 and the WaterMark blue may be 9.5.  Purple can be over 9.5 and high as 10.5.  The 

main goal of the WaterMark is to provide energized water. The change in pH occurs as a result of this energiz-

ing.  Also, it is dependent upon your water source and water flow.  In every case, the water will be energized.  

Question

: When I add drops to the test the water, it turned purple.  Is the pH too high?

Answer

: It is normal for the WaterMark to create a higher pH in the first 1-2 weeks of use. This is due to the 

filters being new. It is perfectly safe to drink. If after 2 weeks of use, the pH is still high, loosen the screw on 

the bottom of the unit. Use a large standard screwdriver to prevent stripping the fitting. Turn clockwise ½ 

turn and retest the water. Continue this until desired pH is obtained. 

Question

: Why does the WaterMark water taste different?

Answer

: If you skipped the 10 minute flush during install, flush the filters now. If you are new to alkaline 

water, the taste may seem foreign. This is normal and will dissipate after the first week of use.  WaterMark 

water is considered among the best tasting waters of the world.  If after the flush, and a few days of drinking 

the water it still tastes different, call technical support.

Question

:  Why has my water flow slowed significantly after a few weeks of use?

Answer

: If source water is extremely dirty and filled with sediment, the filters can become prematurely 

clogged. In this case a filter or filters need to be replaced. Please call customer services to request the re-

placement filters.

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

10

11

Question

: Can the WaterMark be used with a salt-based water softener and a Reverse Osmosis (RO) unit?

Answer

:  It is not suggested that you connect your WaterMark directly to a water supply that comes from 

a salt base softener system as this will damage the unit. If you have a salt softener water system make sure 

you have an RO system or a Nano System connected to the water outlet that will be connected to your Wa-

terMark. If you need to get an RO system or a Nano system please contact customer service.

The watermark can be used with an RO system. You might need to do an under counter installation in this 

case. This installation should be very simple as most RO systems in the market use ¼” tubing and very similar 

to the under sink installation of the WaterMark, but much simpler since you will not need any additional 

parts. First make sure that the water supply to the RO system is closed. Now disconnect the tubing from the 

RO system that goes to your RO faucet and connect this tubing to the back of the WaterMark to the fitting 

labeled “Outlet.” Then, using the ¼” tubing provided with your WaterMark connect the water outlet from 

the RO system to the back of the WaterMark to the fitting labeled “Inlet” Make sure the WaterMark faucet is 

closed to prevent any water from coming out and any leaks. Turn the water supply on and now your Water-

Mark is installed and you will get your water from the RO faucet. Make sure you follow the flushing instruc-

tions before you start drinking the water.

Question

: Can the WaterMark be used in conjunction with a pre-filter? 

Answer

: Yes.

Question

: Can the WaterMark be hooked up and left outside for use?

Answer

: Yes, contact technical support for the quick connect adapter for use on an outside faucet.  Keep the 

unit out of direct sunlight to avoid fading of the color finish or cover with a towel to protect.

Question

: Can I send bottled spring water through the unit?

Answer

: Yes, it will require a pump.  Please contact customer service to order a water bottle pump.

Question

: Can I use lake water?

Answer

:  Even  though  the  WaterMark  is  antibacterial,  we  recommend  using  biologically  safe  water  as  a 

source. In an emergency, lake water could be used with the WaterMark but should not be done on a regular 

basis.

Question

: I was away for a week. Why does my WaterMark water smell like rotten eggs?

Answer

: If left full of water and not used, the mineral filter can develop sulfur. The mineral filter contains 

magnesium that is used to naturally increase the pH and reduce the ORP and when combined with sulfites 

in your source water when water is not running will create a chemical reaction that will release sulfur. This is 

a harmless nutrient. Simply flush your filters for 5 minutes and all odors will be gone. If sulfur smell contin-

ues after flushing, you can open the housing for the 3rd filter (use the filter wrench provided) and add one 

teaspoon of vinegar, let it sit for 10 minutes and then flush for 5 minutes. Also it is recommended that if you 

are going away for several days to remove the 3rd filter, put in a Ziploc bag and store in the refrigerator. After 

you come back, just reinstall and flush for 10 minutes.

Question

: My WaterMark is broken.  What do I do?

Answer

: The unit is covered by one of the industry’s best warranties, please call customer service to obtain 

warranty service.

Question

: Where can I get new WaterMark filters? 

Answer

: Visit 

phmiracleliving.com

 or Call 

760-751-8321

 


background image

pH MIRACLE

THE

®

aterMark

W

aterMark

W

TM

12

WARRANTY

We are so confident in the WaterMark that we offer the industry’s first limited lifetime (lifetime 

of the product is estimated at 10 years) warranty on this product. Even in the water filter indus-

try this is the first product to ever have a such a warranty.

The warranty coverage is simple, for the first 60 days The pH-Miracle Center will replace any 

defective product including shipping both ways. After the first 60 days and for the first 5 years, 

the customer is responsible for shipping fee to The pH-Miracle Center, but we will repair or re-

place any manufacturers defect at 0 cost to the customer and pay the return shipping fee to the 

customer. For the final 5 years, the pH-Miracle Center will cover the cost of parts for any manu-

facturers defect, customer will pay a maximum labor fee of $35.00 for any repair needed, plus 

shipping both ways.

CUSTOMER SERVICE

  760-751-8321

TECHNICAL SUPPORT 

  949-215-2330

WARRANTY NEEDS OR SERVICE

  760-751-8321

EMAIL/WEB SUPPORT

  www.phmiracleliving.com

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

13

Section #6: Usage Instructions

It is important to note that the pH Miracle WaterMark is a natural product designed to improve the 

characteristics of dead Tap or bottled water. Its focus is to first clean the water and then to “energize” 

the water. The energizing of the water is done through natural chemical reaction between minerals 

and by passing water through a vortex energy field. This process produces a superior water that should 

be part of your daily health routine. (Keep in mind that non-WaterMark water ice cubes will dilute the 

WaterMark water.)

If you are new to energized alkaline water then it is a good idea to start slow, drink 1-3 glasses only 

your first day, 2-4 your second and third day and 4-6 your fourth and fifth day. After that go to your full 

amount which for men should be no less than 3-4 liters and woman 2-3 liters. If you have used alkaline 

water or practice the alkaline diet then you may start drinking your full amount from the first day. If you 

are active in sports or exercise and perspire a lot, you can add 2-4 liters per day to the numbers above.

Possible negative side effects for new users are due to detox symptoms which could include headaches, 

fever, runny nose, or body aches. If you experience any of these please do not stop drinking the water, 

this is a positive benefit of detox and will not last more than a day or two. 

It is normal to have to urinate more while using the WaterMark, you may have very urgent needs to 

urinate in the first few weeks of use; this is normal and will soon subside.

All persons should be urinating at least 6-8 times per day, if you have been used to urinating less than 

that you are most likely dehydrated and need to get used to urinating more often. 

When you take WaterMark water with you in bottles like BPA free plastics or glass, the water will hold 

its energy from 14 to 36 hours.

Avoid drinking WaterMark water 30 minutes prior to or after taking prescription medications, as this 

may cause them to break down faster than normal.

Using WaterMark water is beneficial for cooking, soaking fruits and vegetables, growing or sprouting 

food, and for giving to pets. Enjoy.

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

14

Section #7: Maintenance and Filter Changes

The  WaterMark  requires  no  maintenance  other  than  annual  filter  changes.  It  is  also  recom-

mended that if you are going away for a few days to remove the 3rd filter from the unit and store 

in the refrigerator in a Ziploc bag.

To change the filters on the WaterMark, remove the round chrome nut on top of the case and 

lift the case cover off of the WaterMark.

You will see a filter wrench located next to the filters. Remove the wrench.

Be sure water supply is shot off and WaterMark is not holding pressure; to verify this, open the 

WaterMark Faucet Spout or Accessory Faucet and allow any residual pressure to drain.

Take  the  filter  wrench  and  remove  the  filter  caps 

by rotating counterclockwise. Lift the old filter 

cartridge  out  and  press  the  new  cartridge 

in. Filters 1, 3, and 4 will have a small cap 

installed when they are packaged, make 

sure you  remove it  before you  install 

them. Be sure to press the new car-

tridge  completely  into  place  and 

replace the filter cap, then tighten 

with  the  filter  wrench.  Tightness 

level should be snug; do not over 

tighten.  Do  this  one  filter  at  a 

time  to  avoid  placing  filter  car-

tridges  and/or  filter  caps  in  the 

wrong order.

Put  filter  wrench  back  in  place, 

replace  the  case  cover,  and  re-

install round nut to hand tight.

All  WaterMark  filters  will  expire 

and  need  to  be  replaced  every  6 

months, even if usage has been low. 

The filters cannot last under water for 

more  than  6  months,  at  which  point 

they will actually start to release into the 

water what they had once cleaned out.

Wrench

 


background image

aterMark

W

aterMark

W

TM

pH MIRACLE

THE

®

15

A general rule of thumb: for a family of two using the daily recommended amount of water, re-

place filters every 6 months. For a family of four or larger all using more than the recommended 

amount of water, filters might need to be replaces sooner than the recommended 6 months.

For very dirty water or water with lots of sediment, filter #1 may need to be replaced sooner 

than the rest of the filters. The need for this will be indicated if the WaterMark water flow be-

comes very slow before the time to change the filters is up. If this is the case, then replace only 

filter #1.

For best results combine WaterMark water usage with pH Miracle supplements and dietary life-

style. Remember, good health comes from a multifaceted approach of diet, exercise, and emo-

tional health. Good water is the foundation of any health routine and now you have the best! 

Turn  the  chrome  cap  located  on 

top of the machine counterclock-

wise.

Remove the top cover 

to  reveal  the  filter 

housings within.

Use the included wrench 

by  placing  it  above  the 

filter  cap  and  turning 

counterclockwise 

to 

loosen and then remove 

the filter cap.

Remove  the  filters  by 

pulling  up  on  the  filter 

itself.

Replace  one  filter  at  a 

time.

Replace  the  filters  by 

inserting  the  new  filter 

with  the  rubber  O-ring 

towards the bottom.

Finish the installation by 

placing  filter  caps  back 

on  and  tightening  with 

the  included  wrench 

then  placing  the  unit’s 

cover back into place.

Reference for filter appearances.

The bottom end of all the filters has a rubber 

O-ring.

Top view of WaterMark.

FILTERS:

#1  ̶  Sediment Filter

#2  ̶  Ultra Filtration Filter

#3  ̶  Ceramic Filter

#4  ̶  Post Carbon Filter

Filters  are  numbered  clockwise  starting 

at the filter closest to the chrome water 

spout.

Filter #2 may have a flat top, this is 

the same filter and fits all Water-

Mark models.

New filters come with a cap at the bottom. 

Simply pull the cap to remove.