GSM communicator G10T 

(v.2.3X) 

USER MANUAL 

 
 

 
 
 

 
 
 
 

 
 
 

 
 
 

 
 
UAB “TRIKDIS” 
Draugystės str. 17,  

LT-51229 Kaunas 
LITHUANIA 
E-mail: info@trikdis.lt 

Webpage: 

www.trikdis.lt

 

 
 

 

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

1  

www.trikdis.com  

 

GSM communicator G10T v.2 

 

 

Description 
 

GSM communicator can connect to any intruder alarm panel via its landline communicator and  transmit 
messages to an alarm receiving centre (ARC) and/or to a mobile/WEB application. Messages are transmitted 
using GPRS, SMS via GSM network.  
Compatible with control panels which has PSTN telephone communicator. 

 

 

Features

 

 
 

Connection 

Compatible with most control panels 

Connection to control panels via:  

o

TLC terminal connection 

 

Communications 

Communication modes:  

o

GPRS 

o

SMS 

o

DTMF tones 

Primary and backup channels 

If the GPRS connection with primary and backup 
servers  will  be  lost,  information  can  be  sent  in 
SMS messages; 

Mobile/Web application using a cloud service. 
Allowing user to remotely monitor and control 
the alarm system 

Domain can be set as an IP address of IP receiver 

Event messages can be transmitted in Contact ID 
codes 

Event reporting via SMS messages to 4 different 
users in user customized SMS messages 

PING  technology  to  detect  communication 
problems 

Constant control of connection with ARC 

Messages  receivers:  software  IPcom;  hardware 
(HW) receivers RL10 and RM10 and GM5; almost 
every telephone receiver  
 

Configuration 

Quick  and  easy  configuration  and  firmware 
update 

Operating parameters and firmware version can 
be updated remotely 

Operating  parameters  are  set  with  program 
G10config 

 

Inputs and outputs 

1 Output controlled via:  

o

Mobile/Web application 

o

SMS 

o

Internal events 

2 Inputs, type: NC 

 

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

2  

www.trikdis.com  

 

GSM communicator G10T v.2 

Content 

Safety requirements ................................................................................................................................................... 2

 

Liability restrictions ..................................................................................................................................................... 2

 

Communicator G10T operating ................................................................................................................................. 3

 

Technical specification .............................................................................................................................................. 3

 

Package contents....................................................................................................................................................... 3

 

Outside view .............................................................................................................................................................. 3

 

Description of terminal block .................................................................................................................................. 3

 

Light indication ........................................................................................................................................................ 4

 

Communicator installation steps ............................................................................................................................... 4

 

Recommendations for programming of security control panel ................................................................................ 4

 

Wiring diagram .......................................................................................................................................................... 4

 

Setting of operating parameters ............................................................................................................................... 5

 

Protegus service ........................................................................................................................................................ 9

 

Updating communicator firmware version ................................................................................................................. 9

 

Setting of configuration remotely ........................................................................................................................... 10

 

Firmware version upgrading remotely .................................................................................................................... 11

 

Remote PGM output switching ............................................................................................................................... 11

 

 

Safety requirements 

Please read this manual carefully before using the security module G10T
Security communicator G10T should be installed and maintained by qualified personnel, having specific knowledge 
regarding the functioning of GSM devices and safety requirements. 

Communicator G10T should be mounted in places with restricted access and in safe distance from any sensitive electronic 
equipment. The device is not resistant to mechanical effects, dampness and hazardous chemical environment. 

Liability restrictions 

 

When  buying  the  Device,  the  Buyer  agrees  that  the  Device  is  a  part  of  a  security  system  of  premises,  which  sends 
messages about security system status. The Device, when installed, does not diminish the probability of burglary, fire, 
intrusion or other breach of premises. 

 

UAB “TRIKDIS” is not responsible for burglary, fire or any other breach of Buyer’s and/or User’s premises and is not liable 
for any direct or indirect damages incurred thereof. 

 

When buying the Device, the Buyer agrees that the Device supplied by UAB “TRIKDIS” fully meets his requirements for 
intended use. 

 

UAB “TRIKIDIS” provides no guarantees that the Device shall function as declared if the Device is installed and used not 
according to its original purpose, user manual and relevant electronic and technical conditions. 

 

UAB “TRIKDIS” is in no way associated with GSM/GPRS/Internet service providers (operators), thus UAB “TRIKDIS” is in 
no way responsible for any defects in Device operation if they have occurred because of the loss of GSM/GPRS/Internet 
connection, or because of other defects in the service provider network. 

 

UAB “TRIKDIS” has no control and is not responsible for the prices and marketing of network services provided by the 
GSM/GPRS/Internet service providers. 

 

UAB „TRIKDIS” is not responsible if GSM/GPRS/Internet services are not provided to the Buyer and/or User of the Device 
or were cancelled and any direct or indirect damages were incurred thereof. 

 

UAB „TRIKDIS” is not responsible for any direct or indirect damages incurred by the Buyer and/or User of the Device due 
to loss of electricity. 

 

UAB „TRIKDIS” is not liable if Device firmware versions were not updated by the Buyer and/or the User on time. 

 

User  manual  of  the  Device  can  contain  technical  inaccuracies,  grammatical  or  typographical  errors.  UAB  “TRIKDIS” 
reserves the right to correct, update and/or change information in the installation manual.  

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

3  

www.trikdis.com  

 

GSM communicator G10T v.2 

Communicator G10T operation description 

The communicator G10T is connected to security control panel contacts for connecting a telephone landline. In case of an 
event, the security control panel dials number 1234. Module G10T picks up the phone and receives control panel message. 
After receiving the message, the module transmits it to ARC through GSM connection channel set as primary. If the module is 
unable to transmit the message through the primary connection channel, the module can send it through GSM connection 
channel set as backup. Messages are sent through GSM connection according to set IP addresses or telephone numbers. 
If the module loses connection with both the primary and the backup IP addresses, the module can send information to ARC 
with SMS messages. 
If G10T loses communication with both primary and backup IP receiver then it will send Contact ID messages with encrypted 
SMS to SMS receiver (modem) at ARC.  
The  module  can  send  messages  to  specified  recipients  about  the  breakage/restoration  of  external  circuits  IN1  and  IN2
Messages  can  be  sent  with  SMS  messages  to  four  mobile  phones.  SMS  message  can  contain  of  user-friendly  text  which 
describes security control panel event. 
Module output OUT1 state will invert when GSM connection with server at ARC fails/restores or when the module receives 
an SMS message containing of command to change its output state. 
Module can periodically transmit signals PING for testing communication channel. 
Note: if G10T will loose communication with any receiver at ARC, it will send communication trouble signal to alarm control 
panel. 

Technical specification 

Parameter 

Description 

Power supply voltage 

DC 10…16V 

Used current 

60–100 mA (stand-by), 
Up to 250 mA (transmitting) 

GSM modem M12 

Dual-band 900 / 1800 MHz 

Memory 

Up to 60 messages 

Inputs 

2, NC type 

Output 

1 OC type, commutating up to 30 V voltage and current up to 1 A 

Setting configuration 

Through the USB port 

Operating environment 

From -30 °C to 70 °C, with relative air humidity 80% when +20 °C 

Dimensions 

65 x 79 x 25 mm 

Package contents 

Communicator G10T 

1 pc. 

Two-sided adhesive tape (10 cm) 

1 pc. 

 
Note: 
GSM antenna of desired type is collected by the additional request.  

Outside view 

Description of terminal block 

Contact 

Description 

+E 

+12V power supply clamp 

COM 

Common clamp 

TIP 

For connecting to the TIP clamp of security control panel  

RING 

For connecting to the RING clamp of security control panel 

IN1 

1

st

 input clamp (NC type) 

IN2 

2

nd

 input clamp (NC type) 

OUT1 

PGM output clamp (OC type) 

COM 

Common clamp 

MCI 

Provided for future use 

1.

Terminal block 

2.

SIM card holder 

3.

USB socket 

4.

LED indicators 

5.

GSM antenna 

 

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

4  

www.trikdis.com  

 

GSM communicator G10T v.2 

Light indication  

LED 

Operation 

Description 

Network presents status of 
connection to GSM 
network 

Green ON  

Module has been connected to GSM network  

Yellow ON  

Message is being sent 

Green flashing 

Connecting to GSM network 

Yellow flashing 

Number of yellow flashes represent GSM signal strength 

Data presents data 
exchange. 

Green ON  

Unsent messages present in module memory 

Red ON 

Unable messages to be sent  

Green flashing 

Messages are being received from the control panel 

Red flashing rapidly 

Module configuration is incorrect 

Red flashing 

SIM card error 

Power presents power 
supply status, functioning 
of microcontroller and 
programming status 

Green flashing  

Power supply is sufficient, microcontroller is functioning 

Yellow flashing 

Power supply is not sufficient (≤11,5 V) but microcontroller is 
functioning 

Green and yellow flashing in turn 

Programming mode 

Communicator installation steps 

 

Program security control panel  

Use Programming manual of particular security control panel to set operation parameters as following:  

1.

 

Enable the PSTN dialler of the panel. 

2.

 

Select DTMF mode. 

3.

 

Select Contact ID communication format. 

4.

 

Enter a telephone number for dialling (you can use any number not shorter than 2-digits). 

5.

 

Enter a 4-digit account number in the panel

.  

1.

Set  the  operating  parameters  for  the  security  control  panel  telephone 
communicator according to recommendations in section 

Recommendations for 

programming of security control panel

. 

2.

Configure  communicator  parameters  before  installation.  For  communicator 
configuration please refer to chapter Setting Operating Parameters. 

3.

Insert Standard SIM card to the holder. 

Note:  Using your  mobile phone,  register  SIM card  in  the GSM  network  and  enable 
mobile data communication service.  
We recommend do not use prepaid SIM card. 
Disable PIN code request! 

4.

Screw the GPS antenna on. 

5.

Fasten the communicator with adhesive tape. 

6.

Connect wires as shown in 

Wiring diagrams

7.

Connect a DC power supply. 

8.

Check GSM signal strength according to light indication. 

Note:  Sufficient  GSM  signal  strength  is  level  5  (five  yellow  flashes  of  indicator 
Network). If GSM signal strength is not sufficient, use other antenna type. 

9.

Check if the module sends messages according to its configuration. 

Note:  The  message  must  be  sent  and  received  at  the  specified  IP  address  site.  If 
messages are sent to a mobile phone, check if all messages are received. 

 

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

5  

www.trikdis.com  

 

GSM communicator G10T v.2 

Wiring diagram 

 

Setting of operating parameters  

Communicator G10T operating parameters are set with computer program G10config. The program can be found in website 

www.trikdis.lt

.  

 

1.

 

Connect the communicator G10T with a computer using a USB cable. 

a.

 

Download the USB driver file USB_COM.inf for MS Windows OS from the website 

www.trikdis.lt

.  

b.

 

 If the module is connected to a computer for the first time, MS Windows OS should open the window Found New 
Hardware Wizard 
for installing USB drivers.  

c.

 

In the wizard window select the function Yes, this time only and press the button Next

d.

 

When the window Please choose your search and installation options opens, press the button Browse and select 
the place where the file USB_COM.inf was saved. 

e.

 

Follow the remaining wizard instructions to finish the USB driver installation. 

2.

 

Start the program G10config

3.

 

Select the program directory Settings

 

 

a)

 

In the drop-down list  Port select the port to which the 
module is connected. 

 
Note:  specific  port  to  which  the  device  is  connected  will 
appear only when the device is properly connected.  
b)

 

In  the  drop-down  list  Language  select  the  desired 
program language.  

 

1.

 

Press the button Connect/Disconnect [F2/F8]

 

Note:  When  the  module  G10T  is  connected  to  a  computer, 
module LED Power indicator should flash green and yellow in 
turn.  Program  G10config  status  bar  should  indicate 
connection  status  Connected  and  display  the  following 
information about the connected module: 

  Module type 

 Device IMEI number 

      Module serial number 

        Firmware version installed in the module 

 

4.

 

Press the button Read [F7]

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

6  

www.trikdis.com  

 

GSM communicator G10T v.2 

 

a)

 

When the window Access code opens, enter the access 
code (default access code is 1234) and press the button 
OK

 
Note: If you want for the program to remember your access 
code, check the box Remember. Then the Access code 
window will not open when connecting to the module for the 
next time. 

5.

 

Select the program directory Main and set the following parameters: 

 

 

Object ID 

G10T transfers messages of security control panel containing its ID number set in. Here is 
the section for setting ID number (0001-FFFF) for G10T in case to identify to which object 
belong messages generated by particular G10T. Set 4 symbol value; 

SIM Card PIN code 

Section for entering the SIM card PIN code. Leave this field by default if PIN code request is 
disabled; 

User code 

Section for entering a user code. When connected using a User code, only those module 
parameters can be changed, which change were allowed by the administrator; 

Admin code 

Section  for  entering  an  administrator  code.  When  connected  using  an  Admin  code,  all 
module parameters can be changed and also access to parameter change can be restricted 
for persons connecting with the User code. 

Panel type 

Option INTERFACE DTMF means that the module is applied to receive information coded in 
Contact ID format from the telephone communicator of the security control panel in DTMF 
codes; 

IN1 

If here were selected the option 24 zone in the drop-down list then after braking of input 
IN1 external circuit, the module will transmit a message about this event with a code set in 
the table Module events.  
If here were selected the option  Backup mode then  module G10T will start transmitting 
messages of security control panel after breaking input IN1 external circuit only; 

PGM 

If the option Remote control SMS is selected in the drop-down list, the module will change 
its output state after receiving an SMS message containing a control command (See chapter 
Remote output state control). If the option Lost Primary channel is selected, output state 
will change to the opposite after losing communication through the primary channel. When 
the option Lost Secondary channel is selected, output state will change to the opposite after 
losing  communication  through  the  backup  channel.  If  the  option  Lost  Both  channels  is 
selected, output state will change to the opposite after losing communication through the 
primary and backup channels; 

GPRS PING time 

Time  interval  according  to  which  the  module  will  send  signals  PING  for  polling  GPRS 
connection; 

CSD PING time 

The function is disabled; 

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

7  

www.trikdis.com  

 

GSM communicator G10T v.2 

SMS PING time 

Time  interval  according  to  which  the  module  will  send  signals  PING  for  polling  SMS 
communication; 

Test time 

Time interval according to which the module will send messages Test

 

6.

 

The directory GPRS. Enter the parameters are needed for reporting to an alarm receiving centre (ARC): 

 

 

 

Primary reporting 

Select  the  primary  communication  channel  in  the  list,  through  which  the  module  will 
transmit messages to ARC. 
If GPRS is selected, enter the IP address or domain name and the port number of ARC in the 
corresponding boxes Server IP1 address or Domain and Port
If DTMF is selected, enter the telephone number of ARC Tel.1, to which messages will be 
sent through GSM connection in DTMF tones.  The telephone number should be entered 
with international country code but without the “+” (plus) sign. 
If SMS is selected, enter the telephone number of ARC Tel.1, to which SMS messages will be 
sent. The telephone number should be entered with international country code but without 
the “+” (plus) sign. 

If 

Protegus

  is  selected,  all  needed  fields  in  section  Primary  reporting  are  filled  in 

automatically, Backup reporting is disabled. 

ǃ  Write  down  IMEI  code  from  status  bar,  because  you  will  need  it  in  Protegus  service 

registration. How to connect G10 to Protegus see 

Protegus service

Backup reporting 

Drop-down list for setting the backup communication channel, through which the module 
will transmit messages, when connection through the primary communication channel is 
lost. 
If GPRS is selected, enter the second server IP address or domain name and the port number 
of ARC server to the corresponding boxes Server IP2 address or Domain and Port
If DTMF or SMS is selected, enter the telephone number of ARC Tel.2, to which messages 
will  be  sent  through  GSM  connection  in  DTMF  tones  or  SMS  messages.  The  telephone 
number should be entered with international country code but without the “+” (plus) sign. 

Second backup reporting tel 

Telephone number of ARC’s receiver, to which SMS messages will be sent, when the module 
has lost GPRS connection with both servers. This option is allowed, when both the primary 
and the backup  GSM  connection  channels  are  selected as  GPRS.  The  telephone number 
should be entered with international country code but without the “+” (plus) sign. 

Protocol 

Drop-down list for selecting a protocol for encrypting messages; 

Encryption key 

Section for entering a 6-digit key for encrypting messages sent to ARC. The password must 
be same as the password entered in a server program IPcom

Return to primary after 

Used if both the primary and backup GSM channels are selected for connection with ARC. 
Enter  in  the  section  the  duration  of  time  for  sending  messages  though  the  backup 
communication channel, when connection through the primary channel has failed; 

Backup reporting after 

Used if both the primary and backup GSM channels are selected for connection with ARC. 
Enter in the section the number of attempts to transmit information through the primary 
communication channel, after which the module will connect to the backup communication 
channel. 

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

8  

www.trikdis.com  

 

GSM communicator G10T v.2 

Note:  Administrator  of  an  alarm  receiving  centre  (ARC)  should  provide  the  IP  addresses,  port  and  telephone  numbers, 
encryption protocol, key and other parameters necessary for connecting with ARC. 
APN 

Access point name for connecting to the GSM operator’s network; 

User  

User name for connecting to the GSM network; 

Password 

Password for connecting to the GSM network; 

DNS1, DNS2 

We recommend leave values by the default in the sections if you don’t get other.  

Note: APN, user name and password should be provided by the GSM network administrator, from which you have received 
the SIM card. 
Module events 

Module events are described in the table below. After their occurs the module transmits 
messages with codes given beside. Event code can be changed by double-clicking the cells 
Contact ID event code or Contact ID restore code and by entering exact values by Contact 
ID form in the newly opened window. After entering the values press the button OK. 

Communicator 

events 

Meaning of event “E“  

Meaning of event “R“  

TIME 

Internal clock of the module is not set 

Internal clock of the module is set 

TEST 

Periodical module Test message 

 

POWER 

Power supply voltage is lower than 11,5 V 

Power supply voltage has restored to 12,6 V 

TAMPER_1 

External circuit of Input IN1 has broken 

External circuit of Input IN1 has restored 

TAMPER_2 

External circuit of Input IN2 has broken 

External circuit of Input IN2 has restored 

 

7.

 

If you need to set SMS messages for users of security system, choose the directory Text SMS reporting and enter the 
parameters for SMS messages to be sent:  

 

 

 

Telephone 

Telephone numbers T1, T2, T3, T4 of the four users to which SMS messages will be sent. The telephone 
numbers should be entered with international country code but without the “+” (plus) sign; 

Name 

Choose by which tel. number G10T must send SMS after occurring event of particular type. 

Alarm/Restore 

Messages will be sent when the security system is alarmed/restored (events with E/R 1XX codes); 

Open/Close 

Messages will be sent about the arming/disarming of the security system (events with E/R 4XX codes); 

Troubles 

Messages will be sent about the troubles(restores) in system operation (events with E/R 3XX codes); 

Tests 

System test messages will be sent (events with E 6XX codes). 

SMS encoding 

Choose in the list drop-down the preferred encoding for the text in SMS messages; 

Send SMS 

When All is chosen, all messages received from the security control panel will be sent to users. When 
Described Only 
is chosen, SMS messages will be sent only about the events in described zones; 

Object ID 

Enter the object name. It will be included in the message sent to user; 

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

9  

www.trikdis.com  

 

GSM communicator G10T v.2 

Users 

Entries in the table are associated with user codes, with which the security system is armed/disarmed. 
When a user arms/disarms the security system with his code, his name entered in the table will be 
included in the SMS message; 

Zones 

Entries in the table are associated with events in protected zones. When zone is alarmed/restored, its 
name entered in the table will be included in the SMS message; 

Partitions 

If  the  security  system  is  divided  into  several  individually  protected  areas,  entries  in  the  table  are 
associated with these areas. If a zone is alarmed/restored in an area, the name of the partition entered 
in the table will be included in the SMS message; 

Save [F5]

 

By pressing this button values entered to the program G10config can be saved in the computer. A new 
file with extension .gst will be created. It can be used later as a template for configuring other modules.

 

Restore [F11]

 

Button for restoring default (factory) operating parameters of the module G10T. Press the button Yes 
when request window opens.

 

8.

 

Press the button Write [F6] and values entered in the program G10config windows will be uploaded to the module 
G10T. 

9.

 

Press the button Disconnect [F8] and unplug the USB cable from the USB socket. 

Protegus service 

Protegus service allows users to remotely monitor and control the communicator.  
After communicator G10 is set to work with Protegus service and connected to power supply, you can set that G10 
communicator would use open collector output (PGM). The user can trigger the output to activate an input on the host panel to 
trigger a key-switch zone and arm/disarm the system. 
To set PGM for ARM/DISARM system in Protegus application follow these steps:  

1.

 

If you do not have Protegus service account you can create it by fill registration form here: 

www.protegus.eu

.   

2.

 

To add the system to the Protegus, press “Add new system +”, and enter required data, follow steps in pictures. 

 

Updating communicator firmware version 

When the manufacturer adds new features to the module G10T, firmware of the previously bought module can be updated: 

b) Enter IMEI (from G10config status bar). 

a) Enter system name. 

G10 does not have Service code. 

c) Go to Settings 
tab. 

d) Tick "Arm/Disarm with

 PGM". 

e) Save the changes. 

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

10  

www.trikdis.com  

 

GSM communicator G10T v.2 

1.

 

Download the latest G10T_vx.xxx.prg update file from the website 

www.trikdis.lt

2.

 

Connect the module G10T to a computer and start the program G10config. Open directory Firmware update and select 
the file G10T_v2.xxx.prg saved in the computer. 

3.

 

Press the button Start [F9]. Wait until file uploading bar Progress is full, then press the button Disconnect [F8]. Unplug 
the USB cable.  

4.

 

Plug the USB cable back in. Firmware update process may take 60-90 seconds. Wait until indicator Data will stop flashing 
green and press the buttons Connect [F2] and Read [F7]. The new version of the module firmware will be displayed in 
G10config program status bar. 

Setting of configuration remotely 

In order to set module G10T operating parameters remotely a SMS message with the particular syntax must be sent by GSM 
number of SIM card put in the module G10T. When the module G10T receives this SMS message it opens GPRS communication 
session with software IPcom.  

 

If  during  the  previous  setting  module  operating  parameters  were  being  entered 
GSM  number  of  authorised  person  in  the  list  G10config  /  Settings  /  Wireless 
programming phones, 
the module G10T will open GPRS communication session, if 
it receives SMS message with particular syntax from authorized person‘s phone. 
 

 

 
SMS message text structure
 (word 

space

 means space between SMS text symbols): 

 
CONNECT

space

1234

space

SERVER=100.100.100.100

space

PORT=1000

space

APN=provider

space

USR=name

space

PSW=psw

space

ENCR=enc 

 
Note:
 

entering values use capital letters!  

 

 
Description of syntax: 

CONNECT  

Enter the word “CONNECT” means starting command; 

9874 

Enter your 4-digit access code to module parameter configuration (default is 1234); 

SERVER=value 

Enter the word “SERVER=” + enter IP address of the IP receiver, from which module 
operating parameters will be configured; 

PORT=value 

Enter the word “PORT=” + enter port of the receiver, from which module operating 
parameters will be configured; 

APN=value 

Enter the word “APN=” + enter the GPRS access point name of network where SIM 
card is operating. If GSM service provider doesn’t require any value must be entered, 
just leave ...

space

APN=

space

... in SMS; 

USR=value 

Enter the word USR= + enter the User name of GPRS access point name of network 
where SIM card is operating. If GSM service provider doesn’t require any value must be 
entered, just leave ...

space

USR=

space

... in SMS; 

PSW=value 

Enter the word “PSW=” + enter the Password of GPRS access point name of network 
where SIM card is operating. If GSM service provider doesn’t require any value must be 
entered, just leave ...

space

PSW=

space

... in SMS; 

ENCR=value 

Enter the word “ENCR=” + enter the 6-digit messages decrypting key which is set in IP 
receiver (default is 123456). 

 
 
 
 
 
 
 
 
 
 
 
Order of actions after the message is sent: 

 


background image

 

 

 

 

 

©1997-2016 Trikdis  

11  

www.trikdis.com  

 

GSM communicator G10T v.2 

1.

 

Open the window of software IPcom and select the object ID, which operating parameters of transmitting module 
should be changed. To select, right click on the ID number. 

2.

 

Open the configuration program G10config. Left click on the icon G10config has been appeared beside the selected 
ID number. 

3.

 

Click on the button Connect in the opened program G10config tool bar. GPRS connection status “Connected” must 
be indicated in the program’s status bar. Click the button Read [F7] on, old configuration to be displayed. 

4.

 

Further actions are identical as when the module is connected to a computer with a USB cable. Just set the desirable 
values of module operating parameters in the opened program G10config windows. 

5.

 

After entering desirable values click the button Write [F6] on, the values to be set in the module G10T. Just close the 
program G10config and GPRS communication session closes too.   

 

 

Firmware version upgrading remotely 

Connect the module G10T with the program G10config remotely (See previous chapter how to connect remotely). 

1.

 

Open the program G10config (See previous chapter how to open the configuration program) 

2.

 

Press the button Connect

3.

 

To read the parameters set in the module press the button Read

4.

 

Open the window Firmware and with clicking on the button Browse select the latest version of the firmware file. 
Press the button Start

5.

 

Wait until the firmware will be written into the module processor memory. This may take 1-3 minutes, after which 
the module will reconnect to the program G10config

6.

 

Set the module operating parameters in the same way as described while connected via USB port. 

Remote PGM output switching 

In order to change the state of output OUT1, send an SMS message to the SIM card number of the module. Examples of SMS 
messages are provided in the table below. 

Notes: 

 

If the list Wireless programming phones is empty, module will change its output state after receiving an SMS message 
from any mobile phone. If telephone numbers are entered in the list, module output state can be changed only from 
these phones; 

 

Output state can be changed when output OUT1 operating mode is set to Remote control SMS

 

SMS messages have to be written in capital letters only! 

SMS message text 

Meaning 

Note 

OUTPUT

˽

1234

˽

ON 

Output state is changed to ON 

Instead of numbers 1234 enter your 
Administrator or User code 
 
Key 

“˽“ 

means space tab. Spaces in 

notified places must be entered.  

OUTPUT

˽

1234

˽

OFF 

Output state is changed to OFF 

OUTPUT

˽

1234

˽

PULSE=005 

Output state is changed to ON for time 
period given in seconds 

RESET

˽

1234 

Restart module