Made by: Payne
Type: Product Data
Category: Air Conditioner
Pages: 12
Size: 0.12 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

MODEL PA10
10 SEER 3-PHASE AIR CONDITIONER

 

Product Data

 

AVAILABLE SIZES:

 

Nominal sizes available (036, 048 and 060) to
meet the needs of light commercial applications.

 

CERTIFICATION:

 

All models are listed with UL, (U.S. and Can-
ada), ARI, and CEC.

 

ELECTRICAL RANGE:

 

208/230v, three phase in 036, 048 and 060
sizes; and 460v, three phase in 060 size.

 

FAN MOTOR:

 

The totally enclosed fan motor provides greater
reliability under adverse conditions and depend-
able performance for many years. The permanent
split capacitor type motor was designed for opti-
mum efficiency. The motor was then qualified
under extreme conditions to help ensure a long,
reliable life.

 

CABINET:

 

A weather protective cabinet of prepainted steel is
protected underneath by a galvanized coating and
treated with a layer of zinc phosphate for a finish
that will last for many years. All screws on cabinet
exterior are coated for a long-lasting, rust-
resistant, quality appearance.

 

UNIT DESIGN:

 

The copper tube, enhanced sine wave, aluminum
fin coil is designed for optimum heat transfer. Ver-
tical air discharge carries sound and hot con-
denser air up and away from adjacent patio areas
and foliage. The base pan is designed for easy
removal of water, dirt, and leaves.

 

COMPRESSOR:

 

Each compressor is protected with internal tem-
perature- and current-sensitive overloads. An
internal pressure relief valve provides high-
pressure protection to the refrigerant system. For
improved serviceability, all models are equipped
with a compressor terminal plug.

 

3-PHASE

 

Both service valves are brass, front seating type
with sweat connections. Valves are externally
located so refrigerant tube connections can be
made quickly and easily. Each valve has a service
port for ease of checking operating refrigerant
pressures.

 

SERVICE VALVES:

 

Control board that monitors the electrical phase
and prevents compressor operation if wired
incorrectly.

 

SERVICEABILITY:

 

One panel provides access to electrical controls.
Removal of top gives access to fan motor, com-
pressor, and condenser coil.

 

LIMITED

 

Standard 1-year limited warranty on parts and 5-
year limited warranty on compressor.

 

FEATURES 

 

 

(SCROLL 
COMPRESSOR 
UNITS) MONITOR 
BOARD:

WARRANTY:

 


background image

 

—2—

PA10

 

SOUND POWER (dBA) (A-wtd., non-pure tone corrected.)

 

                    NOTE: Tested in accordance with ARI standard 270.95. (Not listed with ARI.)

 

MODEL NUMBER NOMENCLATURE

 

UNIT

SIZE

SOUND

LEVEL

OCTAVE BAND CENTER FREQUENCY (Hz)

125

250

500

1000

2000

4000

8000

 

036-A

82

55.0

64.0

73.0

74.5

72.0

60.5

64.0

048-A

82

61.9

67.5

71.8

77.1

76.5

72.9

66.9

060-A

82

58.0

67.5

78.0

76.0

76.0

73.0

67.0

 

PA10

P

R

Type of Unit

 

PA10 – Electric Air Conditioner 

 

Electrical Supply
P

 

 — 208/230-3-60

 

E

 

 — 460-3

 
   

 

Refrigerant–R22

REGISTERED

ISO 9001:2000

036

000

A

A

AA

Variations

Series

Variation

A — Standard Unit

Heating Capacity

Nominal Cooling Capacity
036

 – 3.0 Tons

048

 – 4.0 Tons 

060

 – 5.0 Tons      

 


background image

 

—3—

PA10

 

 

 

 

AIR IN

NOTES:

1.  Allow 30 in. clearance to service side of

     unit, 48 in. above unit, 6 in. on one side, 12 in.

     on remaining side, and 24 in. between units for proper airflow.

2.  Minimum outdoor operating ambient in cooling mode is

     55

°

F, max. 125

°

F.

3.  Series designation is the 14th position of the unit

     model number.

4.  Center of gravity    .

AIR IN

3

/

8

-IN. DIA

TIEDOWN

KNOCKOUTS

(2) PLACES

H

G

F

E

L

K

J

AIR IN

M

N

AIR DISCHARGE

AIR IN

AIR DISCHARGE

AIR DISCHARGE

A

 

SQ

B

P

C

2

 

7

/

8

1

 1

/

4

FIELD CONTROL SUPPLY 

CONN  

7

/

8

-IN. 

DIA HOLE

FIELD POWER SUPPLY CONN

7

/

8

-IN.

 

DIA HOLE WITH 

1

/

8

-IN. 

DIA KNOCKOUT 

AND 1 

3

/

8

-IN. 

DIA  KNOCKOUT

3

/

8

-IN. 

DIA LIQUID 

LINE CONN

DIA VAPOR LINE CONN

 

DIMENSIONS (IN.)

 

NO

TE:

 

 

The data in this pub

lication is displa

y

ed f

or all ser

ies

, ho

w

e

v

e

r,

 e

v

er

y ser

ies ma

y not be a

v

ailab

le from man

uf

acturer

.

 

UNIT

SIZE

SERIES

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Min Mounting 

P

ad Dim

 

036

A

22-1/2

25-15/16

3-3/16

3/4

3-11/16

18-1/8

19-3/4

22-1/4

14-3/8

19-9/16

22-1/16

10-3/8

10-3/4

11

22-1/2 x 22-1/2

048

A

22-1/2

33-15/16

3-1/4

7/8

3-11/16

18-1/8

19-13/16

22-1/4

14-3/8

19-9/16

22-1/16

10-3/8

10-3/4

15-1/2

22-1/2 x 22-1/2

060

A

3

0

29-15/16

3-1/4

7/8

6-1/2

23-1/2

27-1/4

29-3/4

20

27-1/16

29-9/16

15-1/2

14

15

30 x 30

 


background image

 

—4—

PA10

 

SPECIFICATIONS

 

* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.

† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).

The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 
336-26.

‡ Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.

** Time-delay fuse or circuit breaker.

‡‡ Furnace model numbers P08UA, P08LA, and PG8HA are not compatible with this thermostat.

N/A—Not applicable in this application.

 

NOTES:

 

1. Control circuit is 24v on all units and requires external power source.
2. All motors/compressors contain internal overload protection.
3. Copper wire must be used from service disconnect to unit.

 

UNIT SIZE

036

048

060

 

SERIES

A

A

A

A

Operating Weight (Lb)

122

154

214

Shipping Weight (Lb)

141

175

236

 

ELECTRICAL

 

Unit Volts—Hertz—Phase

208/230-60-3

208/230-60-3

208/230-60-3

460-60-3

Operating Voltage Range*

187-253

187-253

187-253

414-506

Compressor—Rated Load Amps

10.0

12.8

16.0

8.0

Locked Rotor Amps

70.0

91.0

125.0

66.5

Condenser Fan Motor—Full Load Amps

1.4

1.4

1.4

0.8

Min Unit Ampacity for Wire Sizing

13.9

17.4

21.4

10.8

Min Wire Size (60°C/75°F Copper) AWG†

14/14

14/14

12/12

14/14

Max Wire Length (60°C/75°F) (Ft)‡

65/62

52/49

66/63

165/157

Max Branch Circuit Fuse Size**

20

30

30

15

 

COMPRESSOR & REFRIGERANT

 

Compressor—Type

Reciprocating

Scroll

Temperature and Current Protection

Internal Line Break

Refrigerant—Type and Amount (Lbs)

R-22 5.00

R-22 6.25

R-22 8.31

Refrigerant Tubes (In. OD)

Vapor and Liquid (Up to 50 Ft)

3/4 and 3/8

7/8 and 3/8

1-1/8 and 3/8

 

CONDENSER COIL & FAN

 

Coil Face Area (Sq Ft)

9.1

12.4

18.5

Fan Motor—HP, Type, and RPM

1/4 PSC and 1100

1/4 PSC and 1100

Volts—Hertz—Phase

208/230—60—1

208-230—60—1

460—60—1

Condenser Airflow (CFM)

2500

2500

3400

 

OPTIONAL EQUIPMENT

 

Cycle Protector

KSACY0101AAA

Low-Pressure Switch

KAALP0101LPS

High-Pressure Switch

KSAHI0101HPS

Time-Delay Relay

KAATD0101TDR

Winter Start Control

KAAWS0101AAA

Evaporator Freeze Thermostat

KAAFT0101AAA

Compressor Crankcase Heater

KAACH1001AAA

KAACH1201AAA

KAACH1301AAA

Liquid Line Solenoid Valve

KAALS0101LLS

KAALS0101LLS

Filter Drier

P502-8083S

P502-8163S

MotorMaster® Control

32LT660004

32LT660005

Ball Bearing Fan Motor

HC40GE232

HC40GE462

Low-Ambient Pressure Switch Kit

KSALA0201R22

Compressor Sound Hood

KSASH1201COP

KSASH2001CYL

TXV (Hard Shutoff)

KSATX0601HSO

KSATX0701HSO

KSATX1001HSO

Thermostat, Manual Changeover, 

Non-Programmable, °F/°C, 
1-Stage Heat, 1-Stage Cool‡‡

TSTATPPBAC01-B

Thermostat, Manual Changeover, 

5-2-Day Programmable, °F/°C, 
1-Stage Heat, 1-Stage Cool

TSTATPPSAC01-B

Backplate for Standard Thermostat

TSTATXXBBP01

Backplate for Programmable Thermostat

TSTATXXPBP01

Outdoor Air Temperature Sensor

TSTATXXSEN01-B

 

                    METERING DEVICE

 

* Piston listed is for any approved coil non-capillary tube combination. 
Piston is shipped with outdoor unit and must be installed in an approved indoor coil.

 

UNIT SIZE-SERIES

PISTON* 

IDENTIFICATION NO.

 

036-A

70

048-A

82

060-A

93

 

CHARGING SUBCOOLING

(TXV-TYPE EXPANSION DEVICE*)

 

UNIT SIZE

REQUIRED SUBCOOLING 

(°F)

 

036

15

048

15

060

15

 


background image

 

—5—

PA10

 

ACCESSORY USAGE GUIDELINE

 

* For tubing line sets between 80 and 200 ft and/or 20 ft vertical differential, (250 ft total equivalent length), refer to Residential’s Split Systems Long-Line 

Application Guidelines.

† Only when low-pressure switch is used.
‡ Required for MotorMaster Low-Ambient Control (full modulation of motor speed).

 

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)

 

1. Ball Bearing Fan Motor

 

A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.

SUGGESTED USE: Required on all units where Low-Ambient kit (full modulation feature) or MotorMaster® Control has been added.

 

2. Compressor Crankcase Heater

 

An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication 
on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.

SUGGESTED USE: When interconnecting tube length exceeds 80 ft.

When unit will be operated below 55°F (12.8°C) outdoor air temperature. Use with low-ambient controller.
All commercial installations.

 

3. Compressor Sound Hood

 

Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2dBA.

SUGGESTED USE: Unit installed closer than 15 ft to quiet areas—bedrooms, etc.

Unit installed between 2 houses less than 10 ft apart.

 

4. Cycle Protector

 

Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has 
been interrupted for any reason, including normal room thermostat cycling.

SUGGESTED USE: Installations in areas where power interruptions are frequent. 

Where user is likely to ‘‘play’’ with the room thermostat.
All commercial installations.
Installations where interconnecting tube length exceeds 80 ft.
High-rise applications.

 

5. Evaporator Freeze Thermostat

 

An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.

SUGGESTED USE: All units where winter start control has been added.

 

6. Filter Drier

 

A device for removing contaminants from refrigerant circulating in an air conditioning system: single-direction flow.

SUGGESTED USE: Suggested in all field-connected split-system air conditioners.

 

7. High-Pressure Switch

 

Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 400 
psig. Provides additional protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, cycle protector can 
be used with this switch.

SUGGESTED USE: Installations exposed to very ‘‘dirty’’ outdoor air.

Installations where condenser inlet air temperature exceeds 125°F (51.7°C).

 

8. Liquid Solenoid Valve (LSV)

 

An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant 
liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.

SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.

In certain long line applications. (Refer to Long-Line Application Guideline.)

 

9. Low-Ambient Pressure Switch

 

A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure 
within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 
0°F (–17.8°C) when properly installed.

SUGGESTED USE: A Low-Ambient Pressure Switch or MotorMaster®—Low-Ambient Controller must be used when cooling operating is used at outdoor 

temperatures below 55°F (12.8°C).

 

10. Low-Pressure Switch

 

Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 
psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Also, provides additional protection against compressor damage due to loss of refrigerant 
charge. To prevent rapid compressor recycling. Cycle protector can be used with this switch.

SUGGESTED USE: Where indoor coil is exposed to ‘‘dirty’’ air.

All commercial installations.

 

11. MotorMaster® Control

 

A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing 
temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ± 10°F.

SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F.

All commercial installations.

 

ACCESSORY

REQUIRED FOR

LOW-AMBIENT

APPLICATIONS

(Below 55°F)

REQUIRED FOR

LONG-LINE

APPLICATIONS*

(Over 80 Ft)

REQUIRED FOR

SEA COAST

APPLICATIONS
(Within 2 Miles)

 

Compressor Crankcase Heater

Yes

Yes

No

Evaporator Freeze Thermostat

Yes

No

No

Winter Start Control

Yes†

No

No

Accumulator

No

No

No

MotorMaster® Control

Yes

No

No

Wind Baffle

See low-ambient instructions

No

No

Support Feet

Recommended

No

Recommended

Liquid-Line Solenoid Valve

or

Hard Shutoff TXV

No

See Long-Line

Application

Guideline

No

Ball Bearing Fan Motor

Yes‡

No

No

 


background image

 

—6—

PA10

 

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued

 

12. Thermostatic Expansion Valve (TXV) Kits

 

A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the 
evaporator. Kit includes valve, adapter tubes, and external equalizer tube.

SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.

 

13. Time-Delay Relay

 

An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.

SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.

 

14. Winter Start Control

 

An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions.

SUGGESTED USE: All air conditioners where low-ambient controller has been added.

 


background image

 

—7—

PA10

 

RATINGS AND PERFORMANCE

 

See notes on page 8.

 

UNIT

SIZE-SERIES

 INDOOR 

MODEL

TOT. CAP.

BTUH

FACTORY

SUPPLIED

ENHANCE-

MENT

SEER

EER

STANDARD

RATING

PAYNE GAS 

FURNACE OR 

ACCESSORY

TDR†

ACCESSORY

TXV‡

 

036-A

*CC5A/CD5AA036

33,800

NONE

10.00

10.20

10.20

9.15

CAR**3614A**

33,200

TXV

10.00

9.05

CAR**3617A**

33,200

TXV

10.00

9.00

CAR**3621A**

33,200

TXV

10.00

9.00

CAR**4221A**

34,000

TXV

10.00

9.05

CAR**4224A**

34,000

TXV

10.00

9.05

CC5A/CD5AA042

33,800

NONE

10.00

10.20

10.20

9.45

CC5A/CD5AW036

33,800

NONE

10.00

10.20

10.20

9.45

CE3AA036

33,400

NONE

10.00

10.20

10.20

9.10

CE3AA042

33,600

NONE

10.00

10.20

10.20

9.20

CF5AA036

33,600

NONE

10.00

10.20

10.20

9.40

CK3BA036

33,800

NONE

10.00

10.20

10.20

9.45

CK3BA042

33,800

NONE

10.00

10.20

10.20

9.45

CK5A/CK5BA036

33,800

NONE

10.00

10.20

10.20

9.45

CK5A/CK5BA042

33,800

NONE

10.00

10.20

10.20

9.45

CK5A/CK5BT036

33,800

NONE

10.00

10.20

10.20

9.45

CK5A/CK5BT042

33,800

NONE

10.00

10.20

10.20

9.45

CK5A/CK5BW036

33,800

NONE

10.00

10.20

10.20

9.45

CNRV*3617A**

33,200

TXV

10.00

9.00

CNRV*3621A**

33,200

TXV

10.00

9.00

CNRV*4221A**

34,000

TXV

10.00

9.10

CNRH*3617A**

33,200

TXV

10.00

9.05

CNRH*4221A**

34,000

TXV

10.00

9.10

CNRF*3618A**

33,200

TXV

10.00

9.00

CSRH*3612A**

33,200

TXV

10.00

9.15

CSRH*4212A**

34,000

TXV

10.00

9.20

PF1MNB036

33,000

TDR

10.00

10.00

8.90

PF1MNB042

33,800

TDR

10.00

10.00

9.10

PF1MNC036

33,200

TDR&TXV

10.00

8.95

PF1MNC042

34,000

TDR&TXV

10.00

9.05

048-A

*CD5AA048

46,000

NONE

10.00

10.20

10.20

9.25

CAR**4817A**

46,500

TXV

10.50

9.55

CAR**4821A**

46,500

TXV

10.50

9.45

CAR**4824A**

46,500

TXV

10.50

9.45

CAR**6021A**

47,500

TXV

10.50

9.65

CAR**6024A**

47,500

TXV

10.50

9.65

CC5A/CD5AA060

46,500

NONE

10.00

10.20

10.20

9.25

CC5A/CD5AC048

45,000

NONE

10.00

10.00

9.20

CC5A/CD5AW048

46,000

NONE

10.00

10.20

10.20

9.25

CC5A/CD5AW060

47,000

NONE

10.00

10.50

10.50

9.40

CE3AA048

46,000

NONE

10.00

10.20

10.20

9.35

CE3AA060

47,000

NONE

10.00

10.50

10.50

9.45

CF5AA048

46,000

NONE

10.00

10.20

10.20

9.30

CK3BA048

46,000

NONE

10.00

10.20

10.20

9.25

CK3BA060

47,000

NONE

10.00

10.50

10.50

9.45

CK5A/CK5BA048

46,000

NONE

10.00

10.20

10.20

9.25

CK5A/CK5BA060

47,000

NONE

10.00

10.50

10.50

9.45

CK5A/CK5BT048

46,000

NONE

10.00

10.20

10.20

9.25

CK5A/CK5BT060

47,000

NONE

10.00

10.50

10.50

9.45

CK5A/CK5BW048

46,000

NONE

10.00

10.20

10.20

9.25

CK5A/CK5BX060

47,000

NONE

10.00

10.50

10.50

9.55

CNRV*4821A**

46,500

TXV

10.50

9.50

CNRV*4824A**

46,500

TXV

10.50

9.50

CNRV*6024A**

47,500

TXV

10.50

9.65

CNRH*4821A**

46,500

TXV

10.50

9.50

CNRH*6024A**

47,500

TXV

10.50

9.65

CNRF*4818A**

46,500

TXV

10.50

9.45

CSRH*4812A**

46,500

TXV

10.50

9.55

CSRH*6012A**

47,500

TXV

11.00

9.70

PF1MNB048

46,500

TDR

10.00

10.00

9.20

PF1MNB060

48,000

TDR

10.00

10.00

9.20

PF1MNB070

49,000

TDR

10.50

10.50

9.50

PF1MNC048

46,500

TDR&TXV

10.50

9.40

PF1MNC060

47,500

TDR&TXV

10.50

9.60

060-A

*CC5A/CD5AW060

57,000

NONE

10.00

10.20

10.20

9.20

CAR**6021A**

57,000

TXV

11.00

9.60

CAR**6024A**

57,000

TXV

11.00

9.60

CC5A/CD5AA060

55,000

NONE

10.00

10.20

10.20

9.05

CE3AA060

57,000

NONE

10.20

10.50

10.50

9.30

CK3BA060

56,000

NONE

10.00

10.20

10.20

9.15

CK5A/CK5BA060

56,000

NONE

10.00

10.20

10.20

9.15

CK5A/CK5BT060

56,000

NONE

10.00

10.20

10.20

9.15

CK5A/CK5BX060

58,000

NONE

10.20

10.50

10.50

9.35

CNRV*6024A**

57,000

TXV

11.00

9.55

CNRH*6024A**

57,000

TXV

11.00

9.55

CSRH*6012A**

57,000

TXV

11.00

9.60

PF1MNB060

57,500

TDR

10.00

10.00

8.95

PF1MNB070

58,000

TDR

10.50

10.50

9.30

PF1MNC060

57,000

TDR&TXV

10.50

9.30

 


background image

 

—8—

PA10

 

* Tested Combination

† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. 

Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Payne furnaces are equipped with TDR.

‡ Requires hard shutoff TXV; based on computer simulation.

 

EER

 

— Energy Efficiency Ratio

 

SEER

 

— Seasonal Energy Efficiency Ratio

 

TDR

 

— Time-Delay Relay

 

TXV

 

— Thermostatic Expansion Valve

N/A — Not Applicable

 

NOTES:

 

1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other 

combinations are determined under DOE computer simulation procedures.

3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan-coil or furnace-coil literature.
4. Minimum outdoor operating ambient in cooling mode is 55°F (12.8°C), maximum 115°F (46.1°C).
5. The dashes (—) appearing in the SEER WITH ACCESSORY TDR column indicate no improvement in efficiency due to time-delay function built 

into unit as manufactured (see table).

 


background image

 

—9—

PA10

 

DETAILED COOLING CAPACITIES* 

 

See notes on page 11.

 

EVAPORATOR

AIR

CONDENSER ENTERING AIR TEMPERATURES °F

75

85

95

105

115

CFM

EWB

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

 

PA10036-A Outdoor Section With CC5A/CD5AA036 Indoor Section

 

1050

72

40.10

20.78

3.18

38.64

20.34

3.41

36.81

19.70

3.65

34.68

18.95

3.90

32.40

18.12

4.16

67

37.01

25.79

3.10

35.19

25.14

3.32

33.09

24.32

3.55

30.86

23.38

3.76

28.54

22.45

3.96

62

33.44

30.40

3.01

31.46

29.44

3.21

29.48

28.41

3.39

27.41

27.41

3.58

25.59

25.59

3.78

57

31.89

31.89

2.98

30.42

30.42

3.17

28.89

28.89

3.36

27.29

27.29

3.57

25.58

25.58

3.78

1200

72

40.42

21.37

3.26

39.22

21.15

3.49

37.38

20.58

3.73

35.33

19.94

3.98

32.98

19.14

4.25

67

37.76

27.30

3.18

35.93

26.72

3.40

33.80

25.93

3.63

31.50

25.03

3.87

29.07

24.06

4.06

62

34.27

32.45

3.09

32.30

31.46

3.30

30.29

30.29

3.49

28.53

28.53

3.70

26.75

26.75

3.91

57

33.39

33.39

3.07

31.83

31.83

3.29

30.24

30.24

3.49

28.52

28.52

3.70

26.76

26.76

3.91

1350

72

40.97

22.12

3.33

39.58

21.83

3.56

37.81

21.38

3.81

35.78

20.83

4.06

33.34

20.05

4.32

67

38.22

28.62

3.25

36.44

28.16

3.47

34.35

27.51

3.70

31.97

26.61

3.94

29.47

25.55

4.16

62

34.94

34.25

3.17

33.09

33.09

3.38

31.35

31.35

3.62

29.54

29.54

3.82

27.73

27.73

4.04

57

34.56

34.56

3.16

33.04

33.04

3.38

31.33

31.33

3.62

29.60

29.60

3.82

27.74

27.74

4.04

Multipliers for Determining the Performance With Other Indoor Sections

 

Indoor

Section

Size

Cooling

Indoor

Section

Size

Cooling 

Capacity

Power

Capacity

Power

 

CAR**

3614A**

1.00

0.99

CK5A/CK5BT

036

1.00

1.00

3617A**

1.00

0.99

042

1.00

1.00

3621A**

1.00

0.99

CK5A/CK5BW

036

1.00

1.00

4221A**

1.00

0.99

CNRV*

3617A**

1.00

0.99

4224A**

1.00

0.99

3621A**

1.00

0.99

CC5A/CD5AA

036

1.00

1.00

4221A**

1.00

0.99

042

1.00

1.00

CNRH*

3617A**

1.00

0.99

CC5A/CD5AW

036

1.00

1.00

4221A**

1.00

0.99

042

1.00

1.01

CNRF*

3618A**

1.00

0.99

CE3AA

036

0.99

1.00

CSRH*

3612A**

1.00

0.98

042

0.99

0.99

4212A**

1.00

0.97

CF5AA

036

0.99

1.00

PF1MNB

036

0.98

1.01

CK3BA

036

1.00

1.00

042

1.00

1.01

042

1.00

1.00

PF1MNC

036

0.98

0.99

CK5A/CK5BA

036

1.00

1.00

042

1.00

0.99

042

1.00

1.00

 


background image

 

—10—

PA10

 

DETAILED COOLING CAPACITIES* Continued

 

See notes on page 10.

 

EVAPORATOR

AIR

CONDENSER ENTERING AIR TEMPERATURES °F

75

85

95

105

115

CFM

EWB

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

 

PA10048-A Outdoor Section With CC5A/CD5AA048 Indoor Section

 

1400

72

52.44

27.12

4.34

50.89

26.57

4.73

49.02

25.94

5.15

46.92

25.15

5.63

44.62

24.27

6.13

67

48.51

33.51

4.27

46.71

32.83

4.66

44.62

31.96

5.10

42.34

30.99

5.56

39.85

29.96

5.99

62

44.11

39.53

4.21

42.11

38.57

4.58

39.96

37.47

4.95

37.75

36.31

5.36

35.25

35.25

5.78

57

41.80

41.80

4.17

40.16

40.16

4.52

38.49

38.49

4.90

36.83

36.83

5.32

34.92

34.92

5.77

1600

72

53.16

28.05

4.44

51.62

27.58

4.83

49.80

27.01

5.26

47.65

26.30

5.73

45.30

25.45

6.23

67

49.37

35.32

4.36

47.62

34.74

4.75

45.50

33.97

5.19

43.22

33.04

5.65

41.07

32.43

6.09

62

45.15

42.21

4.30

43.15

41.12

4.71

40.91

39.86

5.07

38.62

38.62

5.47

36.50

36.50

5.91

57

43.62

43.62

4.28

41.99

41.99

4.65

40.29

40.29

5.05

38.40

38.40

5.47

36.47

36.47

5.91

1800

72

53.66

28.86

4.53

52.15

28.47

4.92

50.31

27.97

5.36

48.15

27.34

5.82

45.77

26.55

6.32

67

50.02

36.96

4.46

48.25

36.48

4.84

46.10

35.81

5.27

43.78

34.93

5.74

41.76

34.50

6.21

62

45.93

44.48

4.39

43.77

43.77

4.79

41.74

41.74

5.19

40.11

40.11

5.62

37.92

37.92

6.08

57

45.07

45.07

4.38

43.47

43.47

4.79

41.65

41.65

5.19

39.85

39.85

5.61

38.06

38.06

6.04

Multipliers for Determining the Performance With Other Indoor Sections

 

Indoor

Section

Size

Cooling

Indoor

Section

Size

Cooling 

Capacity

Power

Capacity

Power

 

CAR**

4817A**

1.00

0.97

CK5A/CK5BT

048

1.00

1.00

4821A**

1.00

0.98

060

1.00

0.98

4824A**

1.00

0.98

CNRV*

4821A**

1.00

0.98

6021A**

1.01

0.97

4824A**

1.00

0.98

6024A**

1.01

0.97

6024A**

1.01

0.98

CC5A/CD5AA

060

1.00

1.00

CNRH*

4821A**

1.00

0.98

CC5A/CD5AC

048

0.98

0.99

6024A**

1.01

0.98

CC5A/CD5AW

048

1.00

1.00

CNRF*

4818A**

1.00

0.98

060

1.01

0.99

CSRH*

4812A**

1.00

0.97

CD5AA

048

1.00

1.00

6012A**

1.01

0.97

CE3AA

048

1.00

0.99

CK5A/CK5BW

048

1.00

1.00

060

1.01

0.99

CK5A/CK5BX

060

1.01

0.98

CF5AA

048

1.00

0.99

PF1MNB

048

1.00

1.01

CK3BA

048

1.00

1.00

060

1.01

1.02

060

1.00

0.98

070

1.02

1.00

CK5A/CK5BA

048

1.00

1.00

PF1MNC

048

0.99

0.98

060

1.00

0.98

060

1.01

0.98

 


background image

 

—11—

PA10

 

DETAILED COOLING CAPACITIES* Continued

 

* Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor 

unit is located above outdoor unit, a slight variation in capacity may occur.

† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh 

(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air 
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.

** Unit kW is total of indoor and outdoor unit kilowatts.

 

EVAPORATOR

AIR

CONDENSER ENTERING AIR TEMPERATURES °F

75

85

95

105

115

CFM

EWB

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Capacity

MBtuh†

Total

System

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

 

PA10060-A Outdoor Section With CC5A/CD5AA060 Indoor Section

 

1950

72

65.78

33.91

5.12

63.76

33.16

5.59

61.29

32.26

6.11

58.55

31.20

6.68

55.48

30.06

7.30

67

60.83

41.73

5.02

58.56

40.81

5.49

56.01

39.73

6.00

53.08

38.47

6.52

50.44

37.61

7.01

62

55.48

49.20

4.93

53.14

48.04

5.36

50.44

46.70

5.77

47.70

45.29

6.26

44.84

43.75

6.78

57

52.32

52.32

4.84

50.52

50.52

5.26

48.89

48.89

5.76

46.35

46.35

6.19

44.33

44.33

6.69

2000

72

66.67

35.03

5.24

64.66

34.41

5.71

62.19

33.57

6.23

59.39

32.57

6.80

56.30

31.50

7.42

67

61.97

43.97

5.14

59.61

43.12

5.60

57.00

42.08

6.11

54.07

40.90

6.67

50.98

39.65

7.23

62

56.63

52.35

5.04

54.24

51.12

5.51

51.50

49.66

5.93

48.58

48.58

6.40

45.98

45.98

6.96

57

54.52

54.52

5.01

52.66

52.66

5.44

50.94

50.94

5.94

48.24

48.24

6.38

46.15

46.15

6.89

2250

72

67.33

36.04

5.35

65.30

35.52

5.82

62.84

34.77

6.35

60.00

33.87

6.93

56.93

32.86

7.54

67

62.76

46.05

5.25

60.41

45.31

5.71

57.75

44.36

6.22

54.80

43.27

6.78

51.66

41.98

7.37

62

57.55

55.11

5.14

55.14

53.81

5.61

52.43

52.43

6.08

49.85

49.85

6.59

47.51

47.51

7.14

57

56.36

56.36

5.13

54.42

54.42

5.60

52.22

52.22

6.07

49.95

49.95

6.58

47.72

47.72

7.09

Multipliers for Determining the Performance With Other Indoor Sections

 

Indoor

Section

Size

Cooling

Indoor

Section

Size

Cooling 

Capacity

Power

Capacity

Power

 

CAR**

6021A**

0.98

0.96

CK5A/CK5BX

060

1.00

0.98

6024A**

0.98

0.96

CNRV*

6024A**

0.98

0.96

CC5A/CD5AA

060

0.98

0.99

CNRH*

6024A**

0.98

0.96

CC5A/CD5AW

060

1.00

1.00

CSRH*

6012A**

1.00

0.98

CE3AA

060

1.00

0.99

PF1MNB

060

1.01

1.04

CK3BA

060

0.98

0.99

070

1.02

1.01

CK5A/CK5BA

060

0.98

0.99

PF1MNC

060

1.01

1.02

CK5A/CK5BT

060

0.98

0.99

 


background image

 

—12—

 

© Payne Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231

Printed in U.S.A.

edition date: 3/06

Catalog No. SS-PA10-11

Manufacturer reserves the right to change, at any time, specifications or designs without notice and obligations

Replaces: SS-PA10-10

 

SYSTEM DESIGN

 

1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 60 ft, indoor coil below = 200 ft. 
6. For interconnecting refrigerant tube lengths greater than 80 ft or 20 ft vertical differential (250 ft total equivalent length), consult Long-Line Appli-

cation Guideline available from equipment distributor.

7. Crankcase heater required when interconnecting refrigerant tube length exceeds 80 ft.
8. If any refrigerant tubing is buried, provide a minimum 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. 

may be buried without further consideration.

9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.