Full Text Searchable PDF User Manual
English
Model No.
Indoor Unit
Outdoor Unit
CS-S9PKR
CS-S12PKR
CS-S18PKR
CS-S24PKR
CS-S28PKR
CU-S9PKR
CU-S12PKR
CU-S18PKR
CU-S24PKR
CU-S28PKR
Operating Instructions
Air Conditioner
F569363
Operating Instructions
Air Conditioner
Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, read these operating
instructions thoroughly and keep them for future
reference.
2
Quick guide
Inserting the batteries
1
Pull out the back cover of remote control
2
Insert AAA or R03 batteries
(can be used ~ 1 year)
3
Close the cover
Clock setting
1
Press CLOCK
2
Set the time
3
Confi rm
Basic operation
1
Select the desired mode
FAN
AUTO
COOL
DRY
2
Start/stop the operation
POWER
• Please note that the OFF indication
is on
to start.
3
Select the desired temperature
• Selection range: 16 °C ~ 30 °C (Not
applicable for FAN mode).
• Operating the unit within the recommended
temperature may save energy.
COOL: 26 °C ~ 28 °C.
DRY : 1 °C ~ 2 °C lower than room
temperature.
• The set temperature selection range can be
customized according to requirement. Please
consult authorised dealer.
• To dim or restore the unit’s indicator brightness, press
and hold for 5 seconds.
• Use remote control within 8 m from the remote control
receiver of the indoor unit.
The illustrations in this manual are for explanation
purposes only and may differ from the actual unit. They are
subject to change without notice for future improvement.
3
English
Table of contents
Safety precautions ................................
4-5
How to use............................................
6-7
To learn more... ......................................
8
Cleaning instructions ...............................
9
Troubleshooting ....................................
10
Information.............................................
11
Accessories
• Remote control
• AAA or R03 batteries × 2
• Remote control holder
• Screws for remote control holder × 2
1
2
3
ON
OFF
SET
CANCEL
TIMER
1
2
3
SET
CHECK
CLOCK
RESET
AC
RC
ON
OFF
CANCEL
TIMER
1
3
SET
CHECK
RESET
AC
RC
2
3
1
MODE
ON
OFF
SET
CANCEL
TIMER
POWERFUL
FAN SPEED
ECONOMY
1
2
3
SET
CHECK
CLOCK
RESET
AC
RC
MODE
AIR CONDITIONER
OFF/ON
AIR SWING
ON
OFF
SET
CANCEL
TIMER
POWERFUL
FAN SPEED
ECONOMY
1
2
3
SET
CHECK
CLOCK
RESET
AC
RC
MODE
AIR CONDITIONER
AIR SWING
1
2
3
S9PKR, S12PKR
S18PKR, S24PKR,
S28PKR
MODE
ON
OFF
SET
CANCEL
TIMER
POWERFUL
AIR SWING
FAN SPEED
ECONOMY
1
2
3
SET
CHECK
CLOCK
RESET
AC
RC
MODE
AIR CONDITIONER
OFF/ON
ON
OFF
SET
CANCEL
TIMER
POWERFUL
AIR SWING
FAN SPEED
ECONOMY
1
2
3
SET
CHECK
CLOCK
RESET
AC
RC
MODE
AIR CONDITIONER
1
2
3
8m
4
Safety precautions
To prevent personal injury, injury to others or
property damage, please comply with the following:
Incorrect operation due to failure to follow
instructions below may cause harm or damage, the
seriousness of which is classi
fi
ed as below:
WARNING
This sign warns of
death or serious injury.
CAUTION
This sign warns of
injury or damage to
property.
The instructions to be followed are classi
fi
ed by the
following symbols:
This symbol denotes an action
that is PROHIBITED.
These symbols denote actions
COMPULSORY.
WARNING
Indoor unit and outdoor unit
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience
and knowledge, unless they have been given
supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they
do not play with the appliance.
Please consult authorised dealer or specialist to
clean the internal parts, repair, install, remove and
reinstall the unit. Improper installation and handling
will cause leakage, electric shock or
fi
re.
Con
fi
rm with authorised dealer or specialist on
usage of any speci
fi
ed refrigerant type.
Using refrigerant type other than the speci
fi
ed may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive or
fl
ammable atmosphere. Failure to do so could result
in
fi
re.
Do not insert your
fi
ngers or other objects
into the air conditioner indoor or outdoor
unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a long
period to avoid excess cooling.
Do not sit or step on the unit, you may fall
down accidentally.
Remote control
Do not allow infants and small children to play with
the remote control to prevent them from accidentally
swallowing the batteries.
Power supply
Do not use a modi
fi
ed cord,
joint cord, extension cord or
unspeci
fi
ed cord to prevent
overheating and
fi
re.
Indoor unit
Outdoor unit
Power supply
Remote control
Air inlet
Air inlet
Air inlet
Air inlet
Air outlet
Air outlet
Air outlet
Air outlet
5
English
Safety precautions
To prevent overheating,
fi
re or electric shock:
• Do not share the same power outlet with other
equipment.
• Do not operate with wet hands.
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting or
pulling out the power plug.
If the supply cord is damaged, it must be
replaced by the manufacturer, service agent or
similarly quali
fi
ed persons in order to avoid a
hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or
fi
re.
To prevent overheating,
fi
re or electric shock:
• Insert the power plug properly.
• Dust on the power plug should be periodically
wiped with a dry cloth.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/
fi
re/electric shock) Examples of
abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is
observed.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is
switched on for operation.
• The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or
fi
re.
Prevent electric shock by switching off the power
supply and unplug:
- Before cleaning or servicing,
- When extended non-use, or
- During abnormally strong lightning activity.
CAUTION
Indoor unit and outdoor unit
Do not wash the indoor unit with water,
benzine, thinner or scouring powder to
avoid damage or corrosion at the unit.
Do not use for preservation of precise equipment,
food, animals, plants, artwork or other objects.
This may cause quality deterioration, etc.
Do not use any combustible equipment in front of
the air
fl
ow outlet to avoid
fi
re propagation.
Do not expose plants or pet directly to air
fl
ow to
avoid injury, etc.
Do not touch the sharp aluminium
fi
n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the
fl
oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Prevent water leakage by ensuring drainage
pipe is:
- Connected properly,
- Kept clear of gutters and containers, or
- Not immersed in water
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
Remote control
Do not use rechargeable (Ni-Cd) batteries. It may
damage the remote control.
To prevent malfunction or damage of the remote
control:
• Remove the batteries if the unit is not going to
be used for a long period of time.
• New batteries of the same type must be
inserted following the polarity stated.
Power supply
Do not disconnect the plug by pulling the cord to
prevent electric shock.
MODE
ON
OFF
SET
CANCEL
TIMER
POWERFUL
AIR SWING
FAN SPEED
ECONOMY
1
2
3
SET
CHECK
CLOCK
RESET
AC
RC
MODE
AIR CONDITIONER
OFF/ON
ON
OFF
SET
CANCEL
TIMER
1
2
3
CHECK
CLOCK
OFF/ON
6
How to use
To adjust horizontal airfl ow direction
(9PKR, S12PKR)
• Manually adjustable.
Auto OFF/ON button
Use when remote control is
misplaced or a malfunction occurs.
Raise the front panel:
• To use in AUTO mode, press the
button once.
• To use in COOL mode, press and
hold the button until 1 beep is
heard, then release.
• Press the button again to turn off.
S9PKR, S12PKR
S18PKR, S24PKR, S28PKR
MODE
To select operation mode
AUTO - For your convenience
COOL - To enjoy cool air
DRY - To dehumidify the environment
FAN - To circulate air in the room
POWERFUL
To reach
temperature
quickly
POWERFUL
• This operation will stop automatically after 20
minutes.
To enjoy
quiet
operation
QUIET/ECONOMY
• This operation reduces air
fl
ow noise.
FAN SPEED
To select fan speed
(Remote control display)
• For AUTO, the indoor fan speed is
automatically adjusted according to the
operation mode.
Indicator
POWER
TIMER
QUIET/ECONOMY
POWERFUL
(Green)
(Orange)
(Orange)
(Orange)
Press and hold for
approximately
10 seconds to show
temperature setting in
°C or °F.
Press to restore the
remote control to
default setting.
Not used in normal
operations.
Remote control
display
POWERFUL
FAN SPEED
AIR SWING
7
English
How to use
ECONOMY
To save
electrical
power
consumption
QUIET/ECONOMY
• Save power consumption at unoccupied
room by adjust set temperature up to 3°C
automatically.
• Brightness of all indicators will be dimmed.
AIR SWING
To adjust vertical airfl ow
direction
(S9PKR, S12PKR)
(Remote control display)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the
louver swings up/down automatically.
• Do not adjust the louver by hand.
AIR SWING
To adjust airfl ow direction
(S18PKR, S24PKR, S28PKR)
(Remote control display)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver
swings left/right and up/down automatically.
• Do not adjust the louver by hand.
Note
,
POWERFUL
,
ECONOMY
• Can be activated in all modes and can be cancelled by pressing the respective button again.
• Cannot be selected at the same time.
To set the timer
2 sets of ON and OFF timers are available to turn
ON or OFF the unit at different preset times.
ON
OFF
SET
CANCEL
TIMER
1
2
3
CANCEL
TIMER
3
1
2
3
1
Select ON or OFF timer
Example:
OFF at 22:00
• Each time pressed:
OFF
Cancel
2
Set the time
2
3
Confi rm
SET
TIMER
• To cancel ON or OFF timer, press
ON
or
OFF
to
select respective or then press
CANCEL
.
• If timer is cancelled manually or due to power
failure, you can restore the timer again by
pressing
ON
or
OFF
to select respective or
then press
SET
.
• The nearest timer setting will be displayed and
will activate in sequence.
• When ON Timer is set, the unit may start earlier
(up to 15 minutes) before the actual set time
in order to achieve the desired temperature on
time.
• Timer operation is based on the clock set in the
remote control and repeats daily once set. For
clock setting, please refer to Quick guide.
8
To learn more...
Operation mode
AUTO :
During operation mode selection the POWER indicator blinks.
• Unit selects operation mode during startup according to setting temperature and room temperature.
COOL :
Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL
mode.
DRY :
Unit operates at low fan speed to give a gentle cooling operation.
FAN :
To circulate air in the room
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32
23
46
26
Min.
16
11
5
4
9
English
POWER
TIMER
QUIET/ECONOMY
POWERFUL
Cleaning instructions
To ensure optimal performance of the unit,
cleaning has to be carried out at regular
intervals. Dirty unit may cause malfunction
and you may see error code “H99”. Please
consult authorised dealer.
• Switch off the power supply and unplug before
cleaning.
• Do not touch the aluminium
fi
n, sharp parts may
cause injury.
• Do not use benzine, thinner or scouring powder.
• Use only soap ( pH 7) or neutral household
detergent.
• Do not use water hotter than 40 °C.
Indoor unit
Wipe the unit gently with a soft,
dry cloth.
Front panel
Wash gently and dry.
Remove the front panel
POWER
TIMER
QUIET/ECONOMY
POWERFUL
Raise
Pull out
1
2
Close it securely
For CS-S18PKR, CS-S24PKR, CS-S28PKR:
Press at center of the front panel.
4
POWER
TIMER
QUIET/ECONOMY
POWERFUL
Insert at
both sides
1
Press both ends of
the front panel
3
Close down
2
Air fi lters
Every 2 weeks
• Wash/rinse the
fi
lters gently
with water to avoid damage to
the
fi
lter surface.
• Dry the
fi
lters thoroughly under shade, away
from
fi
re or direct sunlight.
• Replace any damaged
fi
lters.
Remove air fi lter
Attach air fi lter
Insert into the unit
Anti-bacterial fi lter
Anti-bacterial
fi
lter.
• Clean the
fi
lter whenever necessary.
• Wash/rinse the
fi
lter gently with water to avoid
damage to the
fi
lter.
• Dry the
fi
lter thoroughly under the shade, away
from
fi
re or direct sunlight.
• Replace the
fi
lter every 10 years or replace any
damaged
fi
lter.
Part no.: CZ-SA22P
For seasonal inspection after extended
non-use
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• Use Auto OFF/ON button to select COOL
operation. After 15 minutes of operation, it
is normal to have the following temperature
difference between air inlet and air outlet
vents:
COOL:
≥
8 °C
For extended non-use
• Turn off the power supply and unplug.
• Remove the remote control batteries.
Aluminium
fi
n
Front panel
Indoor unit
Anti-bacterial
fi
lter
Air
fi
lters
To
learn more... / Cleaning instructions
10
The following symptoms do not indicate malfunction.
Symptom
Cause
Mist emerges from indoor unit.
• Condensation effect due to cooling process.
Water
fl
owing sound during operation.
• Refrigerant
fl
ow inside the unit.
The room has a peculiar odour.
• This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
Indoor fan stops occasionally during automatic
fan speed setting.
• This helps to remove the surrounding odour.
Operation is delayed a few minutes after
restarting.
• The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam.
• Condensation or evaporation occurs on pipes.
TIMER indicator is always on.
• The timer setting repeats daily once set.
POWER indicator blinks before the unit is
switched on.
• This is a preliminary step in preparation for the
operation when the ON timer has been set.
Cracking sound during operation.
• Changes of temperature caused the expansion/
contraction of the unit.
POWER indicator blinks 3 seconds ON and
0.5 seconds OFF during operation.
• The unit is in Demand Response Mode.
Check the following before calling for servicing.
Symptom
Check
Operation in COOL mode is not working
ef
fi
ciently.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the
fi
lters.
• Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation.
• Check if the unit has been installed at an incline.
• Close the front panel properly.
Remote control does not work.
(Display is dim or transmission signal is weak.)
• Insert the batteries correctly.
• Replace weak batteries.
The unit does not work.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
The unit does not receive the signal from the
remote control.
• Make sure the receiver is not obstructed.
• Certain
fl
uorescent lights may interfere with signal
transmitter. Please consult authorised dealer.
Troubleshooting
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND
UNPLUG then please consult authorised
dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the
remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning
properly.
The unit stops and the TIMER indicator
blinks.
Use remote control to retrieve error code.
ON
OFF
SET
CANCEL
TIMER
1
2
3
SET
CHECK
CLOCK
RESET
AC
RC
ON
OFF
SET
CANCEL
TIMER
1
3
SET
CLOCK
RESET
AC
RC
Press for
5 seconds
Press for
5 seconds
to quit
checking
Press until you
hear beep sound,
then write down
the error code
Turn the unit off
and reveal the
error code to
authorised dealer
2
1
3
4
• For certain errors, you may restart the unit for limited
operation with 4 beeps when operation starts.
11
English
T
roubleshooting / Information
Information
English
Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other
Countries outside the European
Union]
These symbols are only valid in the
European Union. If you wish to discard
these items, please contact your local
authorities or dealer and ask for the
correct method of disposal.
Pb
Note for the battery symbol (bottom
two symbol examples):
This symbol might be used in
combination with a chemical symbol.
In this case it complies with the
requirement set by the Directive for the
chemical involved.
F569363
SA0413-0
Printed in Malaysia
Panasonic Corporation
Website: http://panasonic.net/
© Panasonic Corporation 2013