OPES

®

 WEATHER STATION 

INSTRUCTION MANUAL 

 

MODEL: OP-WS01/WH1170

 

           

                                                                                                   

  Page   

1.  Inventory of contents

…………………………………………..……………..  2 

2.  Feature

…………………………………………………………………………..  2 

3.  Set up guide

…………………………………………………………………….  2 

3.1 Battery install

………………………………………………………………. 2                                 

3.2 Mounting

…………………………………………………………………..... 3 

4.  LCD overview

…………………………………………………………………... 4 

4.1    LCD overview

…………………………………………………………….  4 

4.2    Weather forecasting

……………………………..………….…………..  4     

4.3    Weather tendency indicator

………………………………………….... 5 

4.4   

Examples of changing weather icons……………………………….. 5 

4.5    Storm warning indicator

……………………………………….……….  5 

5.  Program modes

……………………………………..……………………….… 5 

5.1    Quick display mode

………………………………………………….…. 5 

5.2    Setting mode

………………………………………………….………….  6 

5.2.1 Setting Calibrated Humidity 

……………………………….…… 6     

5.

2.2 Setting Barometric Pressure……………………………….…… 6 

5.3    Alarm mode

…………………………………………………………….… 7 

5.4    Min/Max mode

……………………………………………………………  8 

6. Problems and interference with operation

………………………...…........  9 

7. Specification

……………………………………………………. ………............ 9 

 

 

 

 

 

This Operation Manual is part of this product and should be kept in a safe place for 

future reference. It contains important notes on setup and operation. 

 
 
 
 
 
 

 

 

 

 


background image

 

 

- 2 - 

 
1. Inventory of contents 

1) 

Base station 

2) One remote sensor with mounting bracket 
3) Instruction manual   

 

2. Feature 

1) Wireless outdoor and indoor humidity (%RH) 
2) Wireless outdoor and indoor temperature (°F or °C)   
3) Records min. and max. humidity 
4) Records min. and max. temperature 
5) Barometric pressure 24-hour history graph (inHg or hPa) 
6) Weather forecast tendency arrow 
7) Forecast icons based on changing barometric pressure   
8) DCF radio controlled time and date with manual setting   
9) Automatically updates for daylight saving time based on Germany DST system     
10) 12 or 24-hour time display   
11) Perpetual calendar   
12) Time alarm with snooze 
13) Can receive information from one sensor   
14) LED backlight   
15) Wall hanging or free standing   
16) Includes remote sensor 
17) Synchronized instant reception

 

 
3. Set up Guide

 

 

3.1 Battery install 
Note

To avoid operating problems, please take note of battery polarity before/when inserting any 

Alkaline Batteries (permanent damaged  can be caused by inserting the battery  the wrong way). 
Use good quality Alkaline Batteries and avoid rechargeable batteries. 

 

1)  Insert two AAA batteries into the remote sensor   
2)  Insert three AA batteries into the Opes

  Weather Station. 

3)  Wait 3 minutes or until the outdoor temperature is displayed on the Opes

  Weather Station.

 Do not 

press any keys before outdoor sensor data is received.

 

4)  Mount  the  units,  ensuring  that  the  receiver  can  still  pick  up  the  signal  from  the  transmitter.  To 

measure outdoor temperature, place the transmitter outdoors. It will transmit the temperature from its 
location. 

 

Every time the remote sensor is powered up (for example after a change of batteries), a random security 
code is transmitted and this code must be synchronized  with the base station to receive  weather data.

 

Therefore, if batteries are changed in the  transmitter, the receiver must be powered up again to 
re-synchronise with the transmitter.

 

After the remote sensor is powered up, the sensor will transmit weather data 6 times every 8s. After this 
learning period is over, the transmitter will transmit every 48s.   
 
When the base station is powered up, a short beep will sound and all LCD segments will light up for about 
3 seconds before it enters into learning mode to learn the sensors security code. After the learning mode, 
the base station will start the DCF radio controlled time reception. The receiver will start Radio Controlled 
Clock (RCC) time reception period (maximum 10 minutes), and no weather data will be received during 
this period of time. If RCC signal cannot be found within1 minute, the signal search will be cancelled and 
will automatically resume every two hours until the signal is successfully captured. Regular RF link will be 
established once RCC reception routine is finished. 

 
Note:  DO  NOT  PRESS  ANY  KEY

 

DURING  THE  FIRST  3  MINUTES  LEARNING  PERIOD

.  After  both 

indoor and outdoor data is displayed you can place your remote sensor outdoors and set your time (if no 
RCC reception is possible). If there is no temperature reading in the indoor station, make sure the units 
are within range of each other or repeat the battery installation procedure. If a key is pressed before the 
Opes™ Weather Station receives the temperature signal, you will need to follow the battery installation 

 


background image

 

 

- 3 - 

procedure  again. 

Please  wait  10seconds  before  you  re-insert  the  battery  to  make  sure  both 

transmitter and receiver reset properly. 
 
Note for Radio Controlled Time: 

The time and date displayed is based on the signal provided by the highly accurate government operated 
atomic clock. The base station will continue to scan for the radio controlled time signal each day despite it 
being manually set. If reception has been unsuccessful, then the radio controlled time icon will not appear 
but reception will still be attempted continually. If reception has been successful, the received time and 
date will overwrite the manually set time and date. 

 

Note: 

 

Please participate in the preservation of the environment by properly disposing of all used-up 
batteries and accumulators at designated disposal points. Never dispose of batteries in a fire as this 
may cause explosion, risk of fire or leakage of dangerous chemicals and fumes 

 

 

 

3.2 Mounting 

1)  Base station 

By using the foldable legs at the back of the unit, the base station can be placed onto any flat surface or 
can be wall mounted at the desired location by the hanging holes at the back of the unit. It is important to 
check  that  the  radio  signal  can  be  received  before  permanently  mounting 
any of the units 

2)  Remote sensor 

To wall mount, use 3 screws to affix the wall bracket to the wall and plug in 
the remote sensor to the bracket. 
 

Note:

 To achieve a true temperature reading, avoid mounting remote sensor 

in direct sunlight. We recommend that you mount the remote sensor on an 
outside North-facing wall; obstacles such as walls, concrete, and large metal 
objects  will  reduce  the  range.  The  unit  should  be  placed  in  a  sheltered 
position where it will not be subjected to direct rain or snow. 
 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

 

 

- 4 - 

 
4. LCD overview 

 

4.1 LCD overview

 

The following illustration shows the full segments of the LCD for description purposes only and will not 
appear like this during normal operation. 

 

1. DST 
2. DCF Radio Controlled Time   
3. Time   
4. Radio Controlled Time icon   
5. Alarm on indicator 
6. Day of week/ time zone 
7. Date 
8. Indoor humidity display 
9. Indoor temperature and humidity low / high alarm   
10. Indoor temperature display 
11. Temperature display unit 
12.  Indoor  temperature  and  humidity  alarm  on 
indicator 
13. Remote sensor transmit signal indicator   
14. MIN/MAX information 
15. Dew point temperature display 

16. Outdoor humidity display 
17.  Outdoor  temperature  and  humidity  low/high         
alarm 
18. Temperature display unit 
19. Outdoor temperature display 
20. General outdoor alarm icon 
21. Weather forecast icon 
22. Weather tendency indicator 
23. Pressure high alarm 
24. Absolute or relative air pressure selection   
25. Pressure low alarm   
26. Pressure with 24 hour history graph   
27. Barometer air pressure 
28. Pressure display unit (inHg or hPa) 
29. Pressure alarm on indicator 

 
4.2 Weather forecasting   

 

 


background image

 

 

Sunny          Partly Cloudy      Cloudy              Rain

 
The four weather icons Sunny, Partly Cloudy, Cloudy and Rainy represent the weather forecasting. There 
are also two weather tendency indicators to show the air pressure tendency between the weather icons.   
The weather forecasting is based upon the change of air pressure.   

 
4.3 Weather tendency indicator 

The weather tendency indicators arrow is located between the weather icons to show the air pressure 
tendency and provide a forecast of the weather to be expected by the decreasing or increasing air pressure. 
The rightward arrow means that the air pressure is increasing and the weather is expected to become 
better. The leftward arrow means that the air pressure is decreasing and the weather is expected to 
become worse. 
 
The change of weather forecast icon is based on the relationship between current relative pressure and the 
pressure change in the previous six hours. If the weather is changing, weather tendency indicator 
(animated arrows) will be flashing for three hours indicating a weather change is happening. After that, if 
weather conditions have become stable and no new weather change condition met, then the arrows will be 
fixed.     
 

4.4 Examples of changing weather icons: 

 

         

 

 

4.5 Storm warning indicator 

 

The storm threshold 

can be set to suit the user’s requirement for storm forecasting from 3-9hPa (default 

4hPa). When there is a fall over pressure threshold within 3 hours, the storm forecasting will be activated, 
the clouds with rain icon and tendency arrows will flash for 3 hours indicating the storm warning feature has 
been activated. 

 

Notes to pressure sensitivity setting for weather forecasting: 

 

The pressure threshold can be set to 

suit the user’s requirement for weather forecasting from 2-4hPa 

(default 2hPa). For areas that experience frequent changes in air pressure require a higher setting 
compared to an area where the air pressure is stagnant. For example if 4hPa is selected, then there must 
be a fall or rise in air pressure of at least 4hPa before the 

Opes™ Weather Station will register this as a 

change in weather.   
 
 
 

5.  Program Mode 

The  base  station  has  five  keys  for  easy  operation: 

SET

  key, 

ALARM

  key,

  MIN/MAX

  key 

+

  key  and 

SNOOZE/LIGHT

 key. And there are four program modes available: 

Quick Display Mode

Setting Mode

Alarm Mode

 and 

Min/Max Mode

.

 

 
The program mode can be exited at any time by either pressing the 

SNOOZE/LIGHT

 key, or waiting for 

the 10-second time-out to take effect. 

 
5.1 Quick Display Mode 

- While in Normal Mode, press the 

SET

 key to enter the Quick Display Mode as follow: 

1.    Outdoor  Temperature  /  Dew  Point  (press  the 

MIN/MAX

  key  or 

+

  key  shifts  the  display  between 

outdoor temperature and dew point) 

2.    Absolute pressure / Relative Pressure (press the 

MIN/MAX

 key or 

+

 key shifts the display between 

 


background image

 

 

- 6 - 

the absolute pressure and relative pressure) 

 
- press the 

SET

 key to accept the changes and advance to the next display mode. Continue to press the 

SET

 key to toggle through the display mode until you return to the normal Mode 

 

5.2 Setting Modes 

Press the 

SET

 key for 3 second while in normal mode to enter the normal Setting mode

 

-

 

Press the 

SET

 key to select the following setting in sequence : 

1) Time Zone Setting (should b

e set at “-1” for UK and “0” For Germany) 

2) 12/24 hour format 

  3) Manual time setting (hours/minutes) 
  4) Calendar setting (year /month /date) 
  5) Temperature display unit degree Celsius or Fahrenheit 
  6) Indoor humidity calibration 
  7) Outdoor humidity calibration 
  8) Air pressure display units in hPa or inHg 
  9) Relative pressure setting from 919.0hPa 

– 1080.0hPa (default 1013.5hPa) 

  10) Pressure threshold setting (default 2hPa) 

11) Storm threshold setting (default 4hPa) 

 

-

 

In the setting modes, press 

+

 key or 

MIN/MAX

 key to change or scroll the value. Hold the 

+

key or 

MIN/MAX

 key for 3 second will increase/decrease digits in greater steps.   

-

 

Press 

SNOOZE/LIGHT

  key  or  no  key  for  10  seconds  and  the  setting  mode  will  revert  to  Normal 

Mode 

 

Note: 

Please first set the units of measurement before attempting to change unit values. During change 

of units setting, 

units’ value will change according to new units but it might cause resolution loss due to its 

internal calculation algorithm. 
 

5.2.1 Setting Calibrated Humidity 

The display console allows you to calibrate both the indoor and outdoor humidity. Humidity is a difficult 

parameter to measure accurately and drifts over time. The calibration feature allows you to zero out this 

error.    To calibrate humidity, you will need an accurate source, such as a hygrometer. 

 

To calibrate indoor humidity, in the Set Mode with indoor humidity flashing, press the 

+

 key or 

MIN/MAX

 

key to increase or decrease the humidity setting (in increments of 1%) to match the calibrated or known 

humidity source.    To return the indoor humidity to the measured value, press and hold the SET key for 3 

seconds and the humidity will return to the uncalibrated value. 

 

To  calibrate  outdoor  humidity,  in  the  Set  Mode  with  outdoor  humidity  flashing,  press  the 

+

  key  or 

MIN/MAX

 key to increase or decrease the humidity setting (in increments of 1%) to match the calibrated 

or known humidity source. To return the outdoor humidity to the measured value, press and hold the SET 

key for 3 seconds and the humidity will return to the uncalibrated value. 

 

Note: 

The remote (outdoor) thermo-hygrometer will always display the measured humidity level and not 

the calibrated humidity level. Only the console will show the calibrated value.   

 

Note: 

The dew point calculation is based on the calibrated humidity level. 

 

5.2.2 Setting Barometric Pressure

 

The  display  console  displays  two  different  pressures:  absolute  (measured)  and  relative  (corrected  to 

sea-level). 

 

 


background image

 

 

- 7 - 

To  compare  pressure  conditions  from  one  location  to  another,  meteorologists  correct  pressure  to 

sea-level conditions. Because the air pressure decreases as you rise in altitude, the sea-level corrected 

pressure  (the  pressure  your  location  would  be  at  if  located  at  sea-level)  is  generally  higher  than  your 

measured pressure. 

 

Thus, your absolute pressure may read 28.62 inHg (969 mb) at an altitude of 1000 feet (305 m), but the 

relative pressure is 30.00 inHg (1016 mb). 

 

The standard sea-level pressure is 29.92 in Hg (1013 mb). This is the average sea-level pressure around 

the  world.    Relative  pressure  measurements  greater  than  29.92  inHg  (1013  mb)  are  considered  high 

pressure and relative pressure measurements less than 29.92 inHg are considered low pressure. 

 

To  determine  the  relative  pressure  for  your  location,  locate  an  official  reporting  station  near  you  (the 

internet  is  the  best  source  for  real  time  barometer  conditions,  such  as  Weather.com  or 

Wunderground.com), and set your 

Opes™ Weather Station to match the official reporting station. 

 

To change the relative pressure when flashing, press the 

+

 key or 

MIN/MAX

 key to increase or decrease 

the relative pressure setting to match the official reporting station. 

 
 

5.3 Alarm Modes 

-      While in Normal Mode press the 

ALARM

 key to enter the High Alarm Mode 

-      Press the 

ALARM 

key again to enter Low Alarm mode 

Remark: after the initial pressing of 

ALARM

 key, the display will be refreshed to show current high, 

low alarm value. Normal alarm value will be displayed only for those already activated, all other not 
activated values will be displayed 

with “---“or”--“instead. 

-      Press the 

ALARM

 key again to return the Normal Mode 

-      In the High Alarm Mode press the 

SET

 key to select the following alarm modes: 

6. 

Time alarm (hour/minute) 

6. 

Indoor humidity high alarm 

6. 

Indoor temperature high alarm 

6. 

Outdoor humidity high alarm 

6. 

Outdoor temperature and dew point high alarm   

6. 

Pressure high alarm 

 
-      In the Low Alarm Mode press the 

SET

 key to select the following alarm modes: 

1.  Time alarm (hour/minute) 
2.  Indoor humidity low alarm 
3.  Indoor temperature low alarm 
4.  Outdoor humidity low alarm 
5.  Outdoor temperature and dew point low alarm 
6.  Pressure low alarm 
 

-      In the alarm modes, Press 

+

 key or 

MIN/MAX

 key to change or scroll the alarm value. Hold the 

+

 key or 

MIN/MAX

 key for 3 second to change the number in greater steps. Press the 

ALARM

 key to choose 

the alarm on or off (if alarm is enabled, the speaker icon on the LCD will be turned on indicating the 
alarm function has been enabled). Press the 

SET

 key to confirm the setting and continue pressing the 

SET

 key to toggle through each alarm mode until it returns to the normal display mode. 

-      Press 

SNOOZE/LIGHT

 key or no key for 10 seconds and the alarm mode will return to Normal Mode 

 
Canceling the Temperature Alarm While Sounding 

a. When a set weather alarm condition has been activated, that particular alarm will sound and flash for 120 
seconds. Press any key to mute the alarm. When weather alarm condition is activated again within 10 
minutes, alarm will not sound but will continue to flash until weather conditions have become more steady. 
This feature is useful to avoid repeated triggering for the same alarm value. 

 


background image

 

 

- 8 - 

b. The alarm will reactivate automatically once the value has fallen below the set value, or if a new value is 
entered. 
 

 
The outdoor weather alarm   

When a set outdoor weather alarm has been triggered, it will flash on the LCD display and the general 
outdoor alarm icon and high/low alarm icon will flash accordingly. For example in outdoor temperature 
display mode, when dew point high alarm is triggered, 

DEW POINT

 icon will flash along with general 

outdoor alarm icon and high alarm icon telling that the current alarm source is from dew point. 

 

 

 

 

 

 

5.4 Min/Max Mode 

 

-

 

While  in  Normal  Mode,  press  the 

MIN/MAX

  key  to  enter  the  maximum  mode, 

MAX

  logo  and  the 

general Max record will be displayed. 

-

 

Press

  MIN/MAX

  key  again  to  enter  the  minimum  mode, 

MIN

  icon  and  minimum  record  will  be 

displayed   

-

 

Press 

MIN/MAX

 key again to return the Normal Mode 

 

-

 

Maximum Reading Reset: In the maximum reading Mode, press the 

+

 key to display the maximum 

values for the readings below together with the time and date time stamp at which these values were 

recorded

. Press 

SET

 key for 2 seconds for each reading to reset the Maximum value to the current reading: 

 

 

1.  Indoor humidity maximum 

2.  Indoor temperature maximum 

3.  Outdoor humidity maximum 

4.  Outdoor temperature maximum   

5.  Outdoor dew point maximum 

6.  Pressure maximum 

 

-

 

Minimum  Reading  Reset:  In  the  minimum  reading  Mode,  press  the 

+

  key  to  display  the  minimum 

values for the readings below together with the time and date at which these values were recorded. 

Press 

SET

 key for 2 seconds for each reading to reset the Minimum value to the current reading:   

1.    Indoor humidity minimum 

2.    Indoor temperature minimum 

3.    Outdoor humidity minimum 

4.    Outdoor temperature minimum   

5.    Outdoor dew point minimum 

6.    Pressure minimum 

 


background image

 

 

- 9 - 

 

-      Press the 

SNOOZE/LIGHT

 key or  no key for 10  seconds, the Min/Max mode  will return  to Normal 

Mode 

 

6.  Problems and interference with operation 

 

Problem & cause 

Remedy   

Poor response inaccurate readings 

Reduce distance between transmitters and receiver to receive 
signal 

High  shielding  materials  between  the 
units  (thick  walls,  steel,  concrete, 
isolating aluminum foil and etc.) 

Find a different location for sensors and/or receiver. See also 
item 

‘transmission range’ below 

 

Interference  from  other  sources  (e.g. 
wireless radio, headset, speaker, etc. 
operating on the same frequency) 

Find a different location for the sensors and/or base station. 
Neighbours using electrical devices operating at the same 
signal frequency can also cause interference with reception 

Poor contrast LCD or no reception or 
low batteries in sensors or receiver 

Change batteries   

Temperature, humidity, or air pressure 
is incorrect. 
 
 

Check/replace batteries. If multiple remote sensors are in use, 
check  location  with  corresponding 

“boxed  numbers”.  Or move 

away from sources of heat/cold. Adjust relative air pressure to a 
value from a reliable source (TV radio, etc.).   

 

 

7.  Specifications 

 

Outdoor data 

Transmission distance in open field     

:        100meter max.   

Frequency                                           

 

:        433MHz   

Temperature range                           

 

:        -40

 to +65

 (show OFL if outside range) 

Resolution                                           

 

:        0.1

 

Measuring range rel. humidity             

:        1%

99%   

Humidity accuracy                                 

:        +/-5% under 0-45

 

Measuring interval thermo-hygro sensor 

48 sec 

Water proof level                               

 

:       IPX3 

 

Indoor data 

Pressure / temperature                                   :       48 sec 
Indoor temperature range                               :       0

 to +60

   

Resolution                                                      :       0.1

 

Measuring range rel. humidity                       :       1%

99% 

Resolution                                                         :       1% 
Measuring range air pressure                       :       919hPa 

– 1080hPa 

Resolution/Accuracy                                       :       0.1hPa/1.5hPa 
Alarm duration                                                  :       120 sec 
 

Power consumption 

Base station

 

                                                    :

       

3XAA 1.5V LR6 Alkaline batteries 

Remote sensor                                                 :       2xAAA 1.5V LR03 Alkaline batteries 
Battery life                                                         :      Minimum 12 months for base station                         
                                                                                    Minimum 24months for remote sensor