PDF User Manual

  1. Home
  2. Manuals
  3. Motorline MC2 User's And Installer's Manual

Motorline MC2 User's And Installer's Manual

Made by: Motorline
Type: User's And Installer's Manual
Category: Control Unit
Pages: 13
Size: 0.47 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

v1.0

REV. 04/2015

MC2

EN

USER / INSTALLER MANUAL 

MC2

 


background image

1A

1B

PT

PT

INDEX 

STANDARDS TO FOLLOW

00. CONTENT

01. SAFETY INSTRUCTIONS

1B

11
11

12

2A
3A

9B

10A

4A

10A

10B

6B
8A

ATTENTION:

 

• To ensure the safety of people, it is important that you read all the following instruc-

tions.

• Incorrect installation or incorrect use of the product can cause physical injury and 

material damage.

• This product was designed and produced strictly for the use indicated in this manual.

Any other use, not expressly indicated here, could compromise the good condition/ope-

ration of the product and/or be a source of danger, and will void the warranty. 

• 

ELECTROCELOS S.A.

 is not responsible for the improper use of the product, or other 

use than that for which it was designed.

• 

ELECTROCELOS S.A.

 is not responsible if safety standards were not taken into ac-

count when installing the equipment, or for any deformation that may occur to it.

• 

ELECTROCELOS S.A.

 is not responsible for the safety and proper operation when 

using components not sold by them.

• Do not make any modifications to the operator components and / or their accessories.

• Before installation unplug the automatism from the source of power.

• The installer must inform the client how to handle the product in case of emergency 

and provide this manual to user.

• Keep remote controls away from children, to prevent the automated

system from being activated involuntarily.

• The customer shall not, under any circumstances, attempt to repair or tune the auto-

matism. Must call qualifid technician only.

• Connect the automatism to a 230V plug with ground wire.

• Control board for indoor use.

STANDARDS TO FOLLOW

TECHNICAL SPECIFICATIONS

PROGRAMMING PRE-RECOMENDATIONS

MAIN MENU

EXTENDED MENU 3

PHOTOCELLS TESTING AND REMOTE CONTROLS

INSTRUCTIONS FOR FINAL CONSUMERS

EXTENDED MENU 1

RESET OF CONTROL BOARD

CAPACITATOR SCHEME

INSTRUCTIONS FOR SPECIALIZED INSTALLERS

EXTENDED MENU 2 

01. SAFETY INSTRUCTIONS

02. THE CONTROL BOARD

03. CONFIGURATION

04. COMPONENT TEST

05. TROUBLESHOOTING

CONTROL BOARD CONNECTION COMPONENT

06. CONNECTION SCHEME

 


background image

2A

2B

PT

PT

02. THE CONTROL BOARD

02. THE CONTROL BOARD

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

The MC2 is a central electronic single phase with incorporated radio, for automation of 

swing gates.

• 

Power supply

230V AC  50-60Hz

• 

Lightbulb’s output

230V AC 500W máx.

• 

Motor’s output

230V AC 50/60 Hz 500W máx.

• 

Auxiliary accessories output

24V AC  15W máx.

• 

Safety and remote controls in BT

24V CC

• 

Working temperature

-10˚C to +55˚C

• 

Protection 

IP56

• 

Incorporated Radio Receiver

433,92 Mhz

• 

OP Transmitters

12-18 bits or Rolling Code

• 

Maximum memory capacity

150 (CODE or CODE PED)

• CONNECTOR’S DESCRIPTION

• DIMENSIONS THE BOX AND CONTROL BOARD 

01

 • Earth connection

02

 • Earth connection

03 

• Earth connection

01

 • AC 230V Line Input (PHASE) 

02

 • AC 230V Line Input (NEUTRAL)

03

 • Lightbulb / Courtesy light’s output (not blink) AC230V (NEUTRAL)

04

 • Lightbulb / Courtesy light’s output (not blink) AC230V (PHASE)

05

 • Motor’s Output 1 opening

06

 • Motor’s Output 1 common

07

 • Motor’s Output 1 closing

08

 • Motor’s Output 2 opening

09

 • Motor’s Output 2 common

10

 • Motor’s Output 2 closing

01

 • Output for power photocells 24V AC

02

 • Output for power photocells (earth)

03

 • Output for electric lock 12V DC 15W (+12V)

04

 • Output for electric lock 12V DC 15W (earth)

05

 • Input PUL button the order opening / closing (NA)

06

 • Input earth common

07

 • Input PUL PED button the order pedestrian (NA)

08

 • Input DS1 safety device 1 (NC)

09

 • Input common GND

10

 • Input DS2 safety device 2 (NC)

11

 • Antenna mass input 

12 

 

Antena hot pole input

CN2

CN3

CN1

205mm

115mm

140mm

252mm

125mm

 


background image

3A

3B

PT

PT

02. THE CONTROL BOARD

02. THE CONTROL BOARD

PROGRAMMING PRE-RECOMENDATIONS

PROGRAMMING PRE-RECOMENDATIONS

• POWER AND SPEED OF MOTORS

The control board has a trimmer VR1 for adjusting the force and speed 

of the motors controlled by the microprocessor. The adjustment can be 

effected between 50% and 100% the power. 

At each start-up movement, the control board applies the maximum 

power during 2 seconds, even when it is made regulating force to a value 

than not the maximum.

FORZA                             

When you adjust the trimmer VR1 has to remake course programming, as they 

could varied the times of maneuvering and deceleration.

+

-

• PROGRAMMING THE CONTROL BOARD - BUTTONS SEL/SET

SEL button: 

It makes the selection of the function to change. The se-

lection is identified by the flashing of the LED corresponding to the 

selected function at that time.

Pressing the SEL button repeatedly will cycle through the various 

functions to be programmed. The selection remains active for 10 se-

conds, after these time the control board returns to original status 

(no active selection).

SET button: 

Makes programming the selected function through the 

SEL button.

                                 

The SET button may be substituted by a remote control from the latter is pro-
grammed.

SET

SEL

• OPERATION OF FLASH LAMP

The operation of the output is conditioned by the mo-

vement of the motor and automatic closing. When the 

automatic closing is activated, the 230V output is ac-

tivated even during pause time.

                    

3 4

• OPERATION WITH TIMER

Instead of a push button opening / closing (PUL), the 

control board can be operated with a TIMER. With a 

TIMER connected to the control board it is possible 

to program an exact time for that the motor perform 

both the opening and closing, in the automatic mode.

5 6

CN3

CN2

Flash lamp:

03 and 04 

 

This output allows connection of a flash lamp (

see page 4B

).

Capacitor:

05 and 07 

 

You must connect the capacitor between the outputs 05 and 07.

08 and 10 

• You must connect the capacitor between the outputs 08 and 10.

Electric lock:

03 and 04 

• This output allows connection of an electric lock (

see pág.9A

)

Push button / selector: 

05 

• Allows connection the push-button / selector to full opening (NA). 

06 

• Allows connection the push-button / selector to full opening (NA). 

Safety circuits:

08 

 

This circuit allows the connection of all types of safety devices such as 

photocells, safety edge, etc. 

This device operates only in the gate closing and, when activated change the 

direction of the automation.

10 

• This circuit allows the connection of all types of safety devices such as 

photocells, safety edge, etc.

This device operates in the opening and closing. In closing, change the direction 

of the automation. In the opening for the movement and when was released 

continues with the opening.

CN2

CN3

CN1

1 2 3

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9 10 11 12

CN2

CN3

Before proceeding to the control board configuration, note the following points listed 

in the table below:

10

 


background image

4A

4B

PT

PT

03. CONFIGURATION

03. CONFIGURATION

The control board allows starting only one motor for the possible passage of peoples. 

With this function, pressing the remote control, only the leave of motor 1 will open.

Programming the remote controls to pedestrian mode (LED CODE PED ON) / the remote 

controls (LED CODE OFF):

01.

 Press the 

SEL

 button once until the 

LED CODE PED

 starts flashing.

02. 

Press the remote control button that you want to program during 1 second.

If you want delete remote controls, press the SET button for 1 second.

03.

 

LED CODE PED

 ON indicates that the remote controls is programmed and deleted 

LED indicates that the remote controls have been deleted.

• CODE PED    | 

PEDESTRIAN OPERATION 

MAIN MENU

MAIN MENU

Mode automatic operates (LED AUT / P-P off):

• 

 

The first impulse the remote control / puss button activates the opening until the end 

of the motor time.

• 

 

The second impulse the remote control / puss button activates the closing until the end 

of the motor time.

If give an impulse before the end of the motor time, the control board will perform a inver-

sion of movement in opening and closing.

Mode of operation step by step (LED AUT / P-P on): 

• 

 

The first impulse the remote control / puss button activates the opening until the end 

of the motor time.

• 

 

The second impulse the remote control / puss button activates the closing until the end 

of the motor time.

If give one order before the end of the motor time, the control board will stop the move-

ment in opening and closing. A new order will return the operation, performed in the other 

direction to what it was before the stop.

The control unit is supplied by the manufacturer with the activated Automatic mode (LED 

AUT / P-P off).

Note: 

If the T. PAUSE is active (on) and stop the gate during the opening, this will keep 

stopped until the end of the pause time, and then make the closing. If you stop during 

• AUT/P-P    | 

AUTOMATIC OPERATION / STEP BY STEP

The control board accepts only Dip-Switch remote controls or Rolling Code MOTORLINE, 

and has a maximum capacity of 150 remote controls. When trying to program the 151 

remote controls, all the programming LEDs will flash simultaneously to indicate that the 

memory is full.

To program new remote controls:

01.

 Press the 

SEL

 button as many times as necessary until the 

LED CODE

 flashes.

02.

 Press once the button remote control you want to program for 1 second.

03.

 The 

CODE LED

 lights up permanently, indicating successful programming.

To delete all configured remote controls:

01.

 Press the 

SEL

 button once, and the 

CODE LED

 will begin to flash.

02.

 Press the 

SET

 button once! The 

CODE LED

 turns off and all remote controls have been 

deleted.

If the 

CODE LED

 starts fast flashing, means that the control board did not accept the 

remote controls programming, because of the following reasons: 

• The remote control is already programmed; 

• The control board accepts only remote controls with rolling code.

• CODE    | 

PROGRAMMING OF REMOTE CONTROLS

closing, it will stop and will restart only when receive new order.

Select operating mode:

01.

 Press the 

SEL

 button once, and the 

LED AUT / P-P

 will start flashing.

02. 

Press the 

SET

 button for 1 second.

03.

 The 

LED AUT/PP

 lit signals that are selecting the mode of operation step by step and 

the LED off signals that is selected the automatic mode.

MAIN MENU

LED

LED OFF

LED aceso

• AUT/P-P

LED OFF

Step by step

• CODE

Automatic 

Inserted code

• CODE PED.

No code

Inserted code

• INB. CMD. AP

No code 

Activated 

• T. MOT.

Deactivated 

Programmed time

• T. MOT. PED

Motor time 30 s.

Programmed time

• T. PAUSA.

Motor time pedestrian 10 s.

With automatic closing 

•  T. RIT. ANTE

Without automatic closing

Programmed time

This is the main menu of the control board MC2, which has access to the most impor-

tant functions of its operation. The control board is supplied with the active main menu.

 


background image

5A

5B

PT

PT

03. CONFIGURATION

03. CONFIGURATION

MAIN MENU

MAIN MENU

With this function can actuate the slowdown, decreasing the gate's movement speed.

NOTA

 

• 

To perform this programming is necessary that the motors have limit switch or 

mechanical stop.

Instead of using the 

SET

 button of the control board, you can use a remote control that 

is already programmed.

The control board is supplied by the manufacturer with a working time of motors estab-

lished within 30 seconds, without deceleration.

Program working time of the motor with deceleration (Gate closed):

01. 

Press the 

SEL

 button the times necessary until the 

LED T.MOT.

 start to flash.

02. 

Press the 

SET

 button for 1 second, so that the Motor 1 start opening. 

If the motor 

does not accept the opening, invert the cable connections 5 and 7, the CN2 connector 

(see page 2B).

03. 

Press the 

SET

 button for 1 second, when the gate is the desired point to start dece-

leration.

04. 

Press again 

SET

 button when you want to establish the opening limit switch. At this 

time, 

LED T. MOT.

 will quickly flashing and automatically the motor 2 starts opening ma-

neuver.

05. 

Press the 

SET

 button for 1 second, when the gate is in the desired point to start de-

celeration.

06. 

Press again 

SET

 button when you want to establish the opening limit switch.

07. 

The 

T. MOT.

 will quickly flashing indicating that programming for closing can be per-

formed and automatically the motor 2 starts the closing maneuver. Repeat the process 

to program the closing. 

• T. MOT AND DECELERATION     | 

MOTOR TIME PROGRAMMING AND DECELERATION

To activate the pedestrian function, the control board allows to be just activated the 

operation of motor 1.

NOTE

 

• 

To perform this programming is necessary that the motors have limit switches 

or stoppers. 

Instead of using the 

SET

 button on the control board, you can use a remote control that 

is already programmed.

The control board is supplied by the manufacturer with a pedestrian working time es-

tablished in 10 seconds without deceleration.

Programming pedestrian working time with deceleration (gates closed):

01.

 Press 

SEL

 button as often as necessary until the 

LED T. MOT. PED.

 starts flashing.

02.

 Press the 

SET

 button for 1 second, so that the Motor 1 start opening. 

If the motor 

does not accept the opening, invert the cable connections 5 and 7, the CN2 connector 

(see page 2B).

03.

 Press the 

SET

 button for 1 second, when the gate is the desired point to start de-

celeration.

04.

 Press again 

SET

 button when you want to establish the opening limit switch. At 

this time, 

LED T. MOT.

 will quickly flashing and automatically the motor 1 starts closing 

maneuver.

05.

 Press the 

SET

 button when the gate is in the desired point to start deceleration.

06.

 Press again 

SET

 button when you want to establish the closing limit switch.

07.

 The 

LED T. MOT.

 will light, signaling that the working time is programmed.

• T. MOT. PED     | 

PROGRAMMING PEDESTRIAN WORKING TIME 

Program working time of the motor without deceleration (Gate closed):

01. 

Press the 

SEL

 button the times necessary until the 

LED T.MOT.

 start to flash.

02. 

Press the 

SET

 button for 1 second, so that the Motor 1 start opening. If the motor 

does not accept the opening, invert the cable connections 5 and 7, the CN2 connector 

(see page 2B).

03. 

Press twice the 

SET

 button when the gate is in the desired point to finish the opening 

course. At this time, 

LED T. MOT.

 will quickly flashing and automatically the motor 2 starts 

opening maneuver.

04. 

Press 

SET

 button two times when desires to establish the opening limit switch.

05.

 The 

T. MOT.

 will quickly flashing indicating that programming for closing can be per-

formed and automatically the motor 2 starts the closing maneuver. Repeat the process 

to program the closing.

With the function activated, the control board rejects all the remote controls signals 

during the opening maneuvers and automatic pause time. It’s important that this func-

tion is activated during a magnetic loop installation, because the control board will 

ignore the crossings performed during the opening and the pause time.

The control board is supplied by the manufacturer with this function deactivated.

Activate (LED ON) / deactivate (LED OFF) function:

01.

 Press the 

SEL

 button the times necessary until the 

LED INB CMD AP

 starts to flash.

02.

 Press 

SET

 button for 1 second to enable / disable the function.

03. 

The 

LED INB CMD AP ON

 indicates that the function is active and the 

LED OFF

 indi-

cates that the function is deactivated.

• INB. CMD. AP     | 

TRANSMITTER INHIBITION DURING THE OPENING AND PAUSE TIME

 


background image

6A

6B

PT

PT

03. CONFIGURATION

03. CONFIGURATION

MAIN MENU

MAIN MENU

The control board permits an automatic closing after a set waiting time, maximum until 

4 minutes.

The control board is supplied by the manufacturer with this function disabled.

NOTE

 

• 

Instead of using the 

SET

 button on the control board, you can use a remote 

control that is already programmed.

Activate (LED ON)/deactivate (LED OFF) function:

1.

 Press 

SEL

 button as often as necessary until the 

LED T. PAUSA

 starts flashing.

2.

 Press the 

SET

 button for 1 second. From that moment, the waiting time before pres-

sing 

SET

 will be equal to the time that the gate stays open.

3.

 Press the 

SET

 button for 1 second, when you reach the time that you want for the 

automatic closing.

4.

 The 

LED T.PAUSA

 

ON

 indicates that the function is active and the LED off indicates 

that the function is disabled.

• T. PAUSA      | 

PROGRAMMING AUTOMATIC CLOSING

The control board is supplied by the manufacturer with an extended menu 1, which 

allows access to more functions of the control board.

To access the options of extended menu 1 follow these instructions:

01.

 Press continuously the 

SET

 button for 5 seconds and the 

LED T.PAUSA

 and 

LED T. 

RIT. ANTE

 will flash alternately. 

02.

 You have 30 seconds to select functions from the extended menu 1 (using the 

SEL

 

and 

SET

 button), and that after this time the control board returns to main menu.

This function can delay up to 15 seconds the start of the closing motor 1 in relation to 

the motor 2.

At the opening, the difference between the motor starting motor 2 to 1 is always 2 se-

conds.

The unit is supplied by the manufacturer with this function disabled.

 

Programming:

01. 

Press the 

SEL

 button as often as necessary until the 

LED T. RIT. ANTE

 starts flashing.

• T. RIT. ANTE      | 

PROGRAMMING DOOR DELAY

EXTENDED MENU 1

LED

LED OFF

LED ON

• AUT/P.P.

PGM distance 

OFF

PGM distance 

ON

• CODE

Photocells test 

ON

Photocells test 

OFF

• CODE PED.

Pressure maintenance 

OFF

Pressure maintenance 

ON

• INB. CMD. AP

Opening push 

OFF

Opening push 

ON

• T. MOT.

Closing push 

OFF

Closing push 

ON

• T. MOT. PED

Safety device 2

Blockade entrance

• T. PAUSA.

Alternative intermittence 

ON/OFF

•  T. RIT. ANTE

Alternative intermittence 

ON/OFF

EXTENDED MENU 1

02. 

Press the 

SET

 button for 1 second. From that moment, the waiting time before pres-

sing 

SET

 will be equal to the time that the gate stays open.

03. 

Press the 

SET

 button for 1 second, when you reach the time that you want. Therefo-

re, on closing, the delay time will be stipulated by the option while the opening is fixed 

in 2 seconds.

04. 

The 

LED T. RIT. ANTE

 will light permanently, indicating the memorization time delay 

between motor 1 and motor 2.

Delete programming:

01. 

Press the 

SEL

 button until the 

LED T. RIT. ANTE

 will flashing.

02. 

Press the 

SET

 button twice in less than 2 seconds.  

03. 

The 

LED T. RIT. ANTE

 will off, signaling the success of the operation.

Programming pedestrian working time without deceleration (gates closed):

01.

 Press 

SEL

 button as often as necessary until the 

LED T. MOT. PED.

 starts flashing.

02.

 Press the 

SET

 button for 1 second, so that the Motor 1 start opening. 

If the motor 

does not accept the opening, invert the cable connections 5 and 7, the CN2 connector 

(see page 2B).

03.

 Press twice the 

SET

 button, when you want to establish the opening limit switch. At 

this time, 

LED T. MOT.

 will quickly flashing and automatically the motor 1 starts closing 

maneuver.

04.

 Press twice the 

SET

 button when you want to establish the closing limit switch.

05.

 The 

LED T. MOT.

 will light, signaling that the working time is programmed.

 


background image

7A

7B

PT

PT

03. CONFIGURATION

03. CONFIGURATION

EXTENDED MENU 1

EXTENDED MENU 1

The control board is supplied by the manufacturer with the deactivated photocells test.

Activate (LED ON)/deactivate (LED OFF) function:

01. 

Activate the extended menu 1

02. 

Press 

SEL

 button once and the 

LED AUT/P-P

 will begin to flash.

03. 

Press 

SET

 button for 1 second

04. 

The 

LED CODE ON

 indicates that the function is disabled and the LED off indicates 

that the function is activated.

NOTE

 

• 

If you do not have the photocells installed, this test will not work.

• CODE      | 

TEST OF PHOTOCELLS

The pressure function of the motors, makes that with control board send the order of 2 

seconds of closing, once every two hours.

The control board is supplied by the manufacturer with functionality to keep pressure 

OFF the hydraulic motors.

Activate (LED ON)/deactivate (LED OFF) function: 

01. 

Activate the extended menu 1.

02.

 Press 

SEL

 button as often as necessary until the 

LED CODE PED

 will flashing 

• CODE PED      | 

MOTORS PRESSURE

With the blocking function activated whenever the photocells (DS2) detected an obsta-

cle, the gate movement will stop and only again be triggered when you press the remote 

control button. Before the gate resume movements, the flash lamp will flash during 5 

seconds.

The control board is supplied by the manufacturer with blocking disabled.

With the closing push function, the control board case is programmed with decele-

ration, will add 1 second acting at full motor power, so that the gate can overcome 

the lock.

The control board is supplied by the manufacturer with the closing push disabled.

Activate (LED ON)/deactivate (LED OFF) function: 

01. 

Activate the extended menu 1.

02. 

Press 

SEL

 button as often as necessary until the 

LED T. MOT.

 will flashing

03.

 Press 

SET

 button for 1 second

04.

 The 

LED T.MOT.

 on indicates that the function is activated and the 

LED

 off indi-

cates that the function is disabled.

• T. MOT.      | 

CLOSING PUSH 

• T. MOT. PED      | 

SAFETY DEVICE 2 / BLOCKING

The function opening push, facilitates the release of the lock when the opening is ac-

tuated, ensuring proper operation.

The control board is supplied by the manufacturer with the opening push disabled. 

Activate (LED ON)/deactivate (LED OFF) function: 

01. 

Activate the extended menu 1.

02. 

Press 

SEL

 button as often as necessary until the 

LED INB. CMD. AP.

 will flashing

03.

 Press 

SET

 button for 1 second

04.

 The 

LED INB. CMD. AP

 on indicates that the function is activated and the 

LED

 off 

indicates that the function is disabled.

• INB. CMD. AP.      | 

OPENING PUSH OF

03.

 Press 

SET

 button for 1 second

04. 

The 

LED CODE PED

 on indicates that the function is activated and the LED off indi-

cates that the function is disabled.

The function of programming the remote controls on distance, it allows them to be ad-

ded remote controls to the new control board without having to use the 

SEL

 button. The 

control board is supplied by the manufacturer with programming remote controls on 

distance deactivated.

Activate (LED ON) / deactivate (LED OFF) function:

01.  

Activate the extended menu 1.

02.  

Press 

SEL

 button once and the 

LED AUT/P-P

 will begin to flash.

03.  

Press for 1 second the 

SET

 button.

04.  LED AUT/P-P

 ON indicates that the function is active and the 

LED

 off indicates that 

the function is disabled.

Programming of remote controls on distance:

01. 

Press for 10 seconds the button of the remote control a previously memorized.

02. LED CODE

 will flash.

 

03. 

Press for 1 second one button of the remote control that you want to program. 

04. 

The flash lamp will flash confirming the success of the operation.

• AUT/P-P      | 

PROGRAMMING OF THE REMOTE CONTROL  ON DISTANCE 

 


background image

8A

8B

PT

PT

03. CONFIGURATION

03. CONFIGURATION

EXTENDED MENU 1

EXTENDED MENU 2

The control board is supplied by the manufacturer with an extended menu 2, which 

provides access to more functions to the control board.

To access the options menu extended 2 proceed as follows:

01. 

Enter the extended menu 1 (see page 06.B). 

02.

 Press continuously the 

SET

 button for 5 seconds and the 

LED T.PAUSA

 and 

LED 

T. RIT. ANTE

 will flash simultaneously.

03.

 You have 30 seconds to select functions from the extended menu 2 (using the 

SEL

 and 

SET

 button), and after this time the control board returns to the main menu.

EXTENDED MENU 2

LED

LED OFF

LED ON

• AUT/P.P.

Follow Me 

OFF

Follow Me 

ON

• CODE

Pre Flash Lamp

 

OFF

Pre Flash Lamp

 

ON

• CODE PED.

Flash lamp on pause

 OFF

Flash lamp on pause

 ON

• INB. CMD. AP

Soft start 

OFF

Soft start 

ON

• T. MOT.

Electronic lock PED 

OFF

Electronic lock PED 

ON

• T. MOT. PED

PUL=PUL | PED=PED

PUL=AB | PED=FECH

• T. PAUSA.

Intermittent ON/OFF simultaneously

•  T. RIT. ANTE

Intermittent ON/OFF simultaneously

With the programmed pause time, it is possible to trigger "Follow Me" option.

With this option enabled, whenever the photocells detected the passage of a user/

object, the control board triggers the closing maneuver after 5 seconds.

Activate (LED ON) / deactivate (LED OFF) function:

01. 

Enter the extended menu 2.

02. 

Press once the 

SET

 button and the 

LED AUT/P-P

 will flash.

03.

 Press once 

SET

 button to enable / disable the function.

The 

LED AUT

/

PP

 ON signals that the function is activated and the 

LED

 OFF signals 

that the function is disabled.

• AUT/P-P    | 

FOLLOW ME

With the functioning in pre flash lamp, the output 03 and 04 (CN2) will always be acti-

vated 3 seconds before the automation start a movement. When disabled, the function 

returns flash lamp.

The control board is supplied by the manufacturer with the pre flash lamp disabled.

Activate (LED ON)/deactivate (LED OFF) function:

01. 

Enter the extended menu 2. 

02.

 Press 

SEL

 button as often as necessary until the 

LED CODE

 will flashing

03.

 Press once 

SET

 button to enable / disable the function.

The 

LED CODE ON

 signals that the function is activated and the 

LED OFF

 signals that 

the function is disabled.  

• CODE    | 

PRE FLASH LAMP/LAMP.CORT

With this option enabled, whenever the motor is in pause time at output 230V for flash 

lamp will stay on.

The control board is supplied by the manufacturer with the flash lamp paused, disabled.

Activate (LED ON) / deactivate (LED OFF) function:

01. 

Enter the extended menu 2.

02.

 Press 

SEL

 button as often as necessary until the 

LED CODE PED

 will flashing.

03.

 Press once 

SET

 button to enable / disable the function.

The 

LED CODE PED ON

 indicates that the function is activated and the 

LED OFF

 signals 

that the function is disabled.  

• CODE PED    | 

OPERATION OF OUTPUT 230V FOR FLASH LAMP DURING THE PAUSE TIME

EXTENDED MENU 2

Activate (LED ON) / deactivate (LED OFF) function: 

01. 

Activate the extended menu 1.

02. 

Press 

SEL

 button as often as necessary until the 

LED T. MOT.

 will flashing.

03. 

Press 

SET

 button for 1 second.

04. 

The 

LED T.MOT.

 on indicates that the function is activated and the 

LED

 off indicates 

that the function is disabled.

 


background image

9A

9B

PT

PT

01

03. CONFIGURATION

03. CONFIGURATION

EXTENDED MENU 2

EXTENDED MENU 2

The electronic lock on the pedestrian function is used when there is, for example, a 

swing doors assembled with electric lock to close the leaf 2. This makes it possible 

to obtain the opening of the gate to trigger a push-button connected in PUL, PED or 

to trigger the remote control.

The remote control is supplied by the manufacturer with the electronic lock on the 

pedestrian function disabled.

Activate (LED ON)/deactivate (LED OFF) function:

01. 

Enter the extended menu 2.

02. 

Press 

SEL

 button as often as necessary until the 

LED T. MOT.

 will flash.

03. 

Press once 

SET

 button to enable / disable the function.

The 

LED T. MOT. ON

 indicates that the function is activated and the 

LED OFF

 signals 

that the function is disabled.

    

The control board permits that the PUL input work with a push button (NA) exclusi-

vely for opening and PED input work with a push button (NA) only for closing. 

The control board is supplied by the manufacturer with the operation of the PUL 

input for connection to a primary push-button (NA) cyclic and PED input for connec-

ting a pedestrian pushbutton (NA) cyclic.

• T. MOT.    | 

ELECTRONIC LOCK IN PEDESTRIAN FUNCTION

• T. MOT. PED   | 

OPERATIONS THE INPUTS PUL AND PED

EXTENDED MENU 3

LEVEL OF THE POWER 

LEDS ON

1

AUT/P-P.

2

AUT/P-P. • CODE

3

AUT/P-P. • CODE • CODE PED

4

AUT/P-P. • CODE • CODE PED • INB. CMD. AP

5

AUT/P-P. • CODE • CODE PED • INB. CMD. AP • T. MOT.

6

AUT/P-P. • CODE • CODE PED • INB. CMD. AP • T. MOT. • T. MOT. PED

With the extended menu 3 can program the power / motor speed at which will be per-

formed the deceleration.

To access the options menu Extended 3 proceed as follows:

01. 

Enter the extended menu 1 (

see page 06.B

).

02.

 Enter the extended menu 2 (

see page 08.A

).

03.

 Continuously press the 

SET

 button for 5 seconds and the 

LED T.PAUSA

 and 

LED T. 

RIT. ANTE

 will flash alternately a few moments, past to flash simultaneously immedia-

tely afterwards. 

04.

 You have 30 seconds to select from the extended menu functions 3 (using the 

SEL

 

and SET button), and after of this time the control board returns to the main menu.

EXTENDED MENU 3

PUL= opening, PED= closing (LED ON) / PUL=PUL and PED=PED (LED OFF):

01. 

Enter the extended menu 2.

02.

 Press 

SEL

 button as often as necessary until the 

LED T. MOT. PED

 will flash.

03.

 Press once 

SET

 button to change the function.

The 

LED T. MOT. PED ON

 signals that the 

PUL

 is programmed for opening and 

PED

 to 

closing. The LED off indicates that the function 

PUL

 if found programmed to func-

tion with a main push button (NA) cyclic and 

PED

 input for connecting a pedestrian 

pushbutton (NA) cyclic.  

With function "Soft Start" enabled, the beginning of each movement, the control board 

will control start the motor, increasing power gradually in the first 2 seconds of opera-

tion.

The control board is supplied by the manufacturer with the "Soft Start" disabled.

Activate (LED ON) / deactivate (LED OFF) function:

01. 

 Enter the extended menu 2.

02.

 Press 

SEL

 button as often as necessary until the 

LED INB. CMD. AP.

 will flashing.

03.

 Press once 

SET

 button to enable / disable the function.

The 

LED INB. CMD. AP. ON

 indicates that the function is activated and the 

LED OFF

 sig-

nals that the function is disabled.   

• INB. CMD. AP.    | 

SOFT START

 


background image

10A

10B

PT

PT

03. CONFIGURATION

EXTENDED MENU 3

CAPACITORS CONNECTION SCHEME

To detect which components have problems on an automated system, sometimes it is 

necessary to conduct tests using a direct connection to a 230V AC power supply. For 

this it is necessary to merge a 8μF capacitor to make the automation to work. In the 

scheme below is shown how this link should be made and how to merge the different 

wires of the components.

NOTES:

 

   • To perform these tests you don’t need to remove the automation from where it is 

installed, because this way you can know if connected directly to power supply it will 

work correctly. 

   • The order of wiring capacitor to motor wires is not important, as long you connect 

one  wire to brown wire of motor and the other one to black wire of motor; 

   • Common wire should always be connected to power supply. 

   • To reverse motor direction, just replace black wire with brown wire of the operator 

on the power supply.  

04. COMPONENT TEST

This test only applies to 230V motors. To test a 24V motor, just connect the 

motor cables to a 24V battery.

01

If you need to restore central with factory setting, press the SEL and SET buttons si-

multaneously. All LEDs will light up temporarily, and when deleted is confirmed the 

success of the operation.

The control board is prepared to a safety device connection in accordance with the sec-

tion 5.1.1.6 of standard EN 12453. In every maneuver is performed a test for the Security 

Device and the Lock. In case of a function/connection failure the motor doesn’t start 

and every LED’s remain in a intermittent mode, indicating the error. When the photoce-

lls operation is corrected, the control board returns to it’s normal functioning. This ac-

tion by the control board allows to recognize failures in accordance with is mentioned 

in category 2 of EN 954-1.

In the position corresponding to each transmitter input in low voltage, the control board 

has a LED to identify the condition of it. The LED on indicates that the input is closed, 

while the LED off indicates that the input is open.

• PHOTOCELLS TEST 

• REMOTE CONTROLS TESTE

PHOTOCELLS AND CONTROLS TEST

RESET TO CONTROL BOARD

CAPACITOR 8μF

AUTOMATION

230V POWER 

SUPPLY

Earth wire

Brown

Black

Common  (Blue)

Motor power programming during the deceleration:

It is possible to choose up to 6 different levels, relatively the force that the motor per-

forms in deceleration. The levels are represented by combinations of the 

LED

 indicated 

in the table above.

Scroll through the 

LEDs

 with the 

SEL

 button to set the desired power, knowing that the 

LED AUT / P-P. ON

 corresponds to minimum power, while the 

LEDs AUT / P-P.

CODE

CODE PED

INB. CMD. AP, T. MOT.

T. MOT. PED ON

 corresponds to maximum power.

The control board is supplied by the manufacturer with the power regulated at level 3 

(

AUT / P-P.

CODE

CODE PED ON

).

 


background image

11

PT

INSTRUCTIONS FOR SPECIALIZED INSTALLERS

05. TROUBLESHOOTING

FINAL CONSUMERS INSTRUCTIONS

Anomaly

Procedure

Behavior

Procedure II

Discovering the origin of the problem

• Motor 

doesn't work

• Make sure you 

have 230V power 

supply connected to 

automation and if it is 

working properly.

• Still not working 

• Consult a qualified 

MOTORLINE

 technician.

• Motor 

doesn’t move 

but makes 

noise

• Unlock motor and 

move the gate by hand  

to check for mechani- 

cal problems on the  

movement.

• Encountered 

problems?

• Consult an experienced 

gate expert.

1 • Check all motion axis and associated motion systems related with the motor and the gate to find out what is the problem.

•  The gate moves 

easily?

• Consult a qualified 

MOTORLINE

 technician.

• Motor opens 

but doesn’t 

close

• Unlock motor and 

move the gate by hand 

to closed position. 

Lock motor again and 

turn off power supply 

for 5 seconds. Recon- 

nect it and send order 

to open gate using 

transmi- tter.

• Gate opened but 

didn’t close again.

1 • Check if there is any 

obstacle in front of the 

photocells; 

2 • Check if any of the control 

devices (key selector, push 

button, video intercom, etc.)  

of the gate are jammed and 

sending permanent signal to 

control unit; 

3 • Consult a qualified 

MOTORLINE

 technician

• Gate doesn’t 

make

complete 

route

• Unlock motor and 

move gate by hand  to 

check for mechanical 

problems on the  gate.

• Encountered 

problems?

• Consult an experienced 

gate expert.

1 • Check all motion axis and associated motion systems related with the gate to find out what is the problem.

•  The gate moves 

easily?

•  Consult a qualified 

MOTORLINE

 technician.

1 • Open control board and check 

if it hás 230V power supply;

2 • Check the control board input 

fuses;

3 • Disconnect the motor from 

control board and test them by 

connecting directly to power 

supply in order to find out if they 

have problems

(see page 10.B). 

4 • If the motor works, the 

problem is on the control board. 

Pull it out and send it to our 

MOTORLINE

  technical services 

for diagnosis; 

5 • If the motor doesn’t work, 

remove them from  installation 

site and send to our 

MOTORLINE

 

technical services for diagnosis.

1 • Check capacitors, testing 

operator with new capacitors;

2 • If capacitors are not the 

problem, disconnect motors from 

control board and test them by 

connecting directly to power 

supply in order to find out if they 

have problems (

see page 10.B

);

3 • If the motors work, the 

problem is from control board. 

Pull it out and send it to our  

technical services for diagnosis;

4 • If the motors doesn’t work, 

remove them from installation 

site and send to our 

MOTORLINE

 

technical services for diagnosis.

1 • Check capacitors, testing with 

new capacitors; 

2 • If capacitors are not the 

problem, disconnect motor 

from control board and test it 

by connecting directly to power 

supply in order to find out if it is 

broken; 

3 • If the motor doesn’t work, 

remove it from  installation site 

and send to our 

MOTORLINE

 

technical services for diagnosis.

4 • If motor work well and move 

gate at full force during the entire 

course, the problem is from 

controller. Set force using 

trimmer on the board. Make a 

new working time  programming , 

giving suffient time for opening 

and closing with appropriate 

force (page 08.B).

5 • If this doesn’t  work, remove 

control unit and send it to 

MOTORLINE

 technical services 

services.

NOTE:

 

Setting force  of the controller 

should be sufficient to make the 

gate open and close  without 

stopping, but should stop and 

invert with a little effort from a 

person. In case of safety systems 

failure, the gate shall never cause  

physical damaged to obstacles 

(vehicles, people, etc.).

All 

MOTORLINE

 control boards have LEDs that 

easily allow to conclude which devices are  

with anomalies. All safety devices LEDs (DS) 

in normal situations remain On. All "START"  

circuits LEDs in normal situations remain Off.

If LEDs devices are not all On, there is some 

security systems malfunction  (photocells, 

safety edges), etc. If  "START" circuits LEDs 

are turn On, there is a control device sending 

permanent signal.

A) SECURITY SYSTEMS:

1 • Close with a shunt all safety systems 

on the control board (check manual of the 

control board in question). If the automated 

system starts  working normally check for the 

problematic device.

 

2 • Remove one shunt at a time until you find 

the malfunction device. 

3 • Replace it for a functional device and 

check if the motor works correctly with all the 

other devices. If you find another one 

defective, follow the same steps until you find  

all the problems.

B) SISTEMAS DE START:

1 • Disconnect all wires from START terminal 

input.

2 • If the LED turned Off, try reconnecting one 

device at a time until you find the defective 

device. 

NOTE

: In case procedures described in 

sections A) and B) don’t result, remove control 

board  and send to our technical services for 

diagnosis.

 


background image

12

PT

V

PU

L

SERR.

PED

L       N

LAMP 230V

MO

TO

RE 1

AP COM CH

MO

TO

RE 2

AP COM C

H

PUL

PED

DS1

DS2

PL

L

N

~

~

~

~

~

~

~

~

0V

12/24V

0V

12/24V

0V

NC

CO

M

12/24V

0V

NC

CO

M

12/24V

1

-

3

COM

K1

K2

2

+

4

NC

5

NO

1

-

3

COM

K1

K2

2

+

4

NC

5

NO

1

-

2

+

1

-

2

+

SEL

SET

T.

RI

T.

AN

T

T.

 P

AUSA

T.

MO

T.

PED

T.

MO

TO

R

INB.

CM

D.

AP

CODE PED

CODE

AU

T/

P-

P

06. CONNECTION SCHEME

CONTROL BOARD CONNECTION COMPONENT

Int

erior Pho

tocells

Ext

erior Pho

tocells

Mo

tor 1

 s

tar

ts opening be

for

e Mo

tor 2 - 

Mo

tor 2

 s

tar

ts cl

osing be

for

e Mo

tor 1 

- It mus

t be  ap

plied an 8

μ capacit

or in 

eac

h mo

tor

, on the opening and cl

osing 

wir

es as e

xplained abo

ve

.

NO

TE • 

If an

y one o

f the mo

tor

s mo

ves in 

the wr

ong w

ay

, jus

t s

wit

ch the br

own and 

blac

k cabl

es o

f tha

t mo

tor t

o c

hang

e the 

dir

ec

tion.

Compl

et

Opening (2  lea

ves)

Lo

ck

Ligh

t Bulb

Ant

enna

Earth wire

Black

Brown

Earth wire

Blue

Blue

Brown

Black

P

edes

trian 

Opening (1  leaf)

Mo

tor 1

Mo

tor 2

- F

or

ça +

1D

1D

DS

S2

For

ce