PDF User Manual

  1. Home
  2. Manuals
  3. LockState LS-S100 User Manual

LockState LS-S100 User Manual

LS-N100

Made by: LockState
Type: User Manual
Category: Door locks
Pages: 11
Size: 0.6 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

LS-S100 LS-N100 

Standalone Keypad Access Control 

 

User Manual 

 

   

 

 

 

 

 

Please read the manual carefully before use this unit   

 

 


background image

 

 

 

1.  Packing List 

Name 

  Quantity 

Remarks 

Keypad 

      1 

 

User manual 

      1 

 

Screw driver   

      1 

Φ20mm×60mm,

Special for keypad

 

Rubber plug 

      2 

Φ6mm×30 mm, used for fixing 

Self tapping screws 

      2 

Φ4mm×28 mm, used for fixing 

Star screws

 

      1 

Φ3mm×6mm, used for fixing 

Please  ensure  that  all  the  above  contents  are  correct.  If  any  are  missing  please  notify  the 

supplier of the unit.   

2. Quick Reference Programming Guide

 

To enter the programming mode 

*    Master code    # 

999999 is the default factory master code   

To exit from the programming mode 

  *   

Note that to undertake the following programming the master user must be logged in 

To change the master code 

0    New code    #    New code    # 

The master code can be 6 to 8 digits   

To add a PIN user. 

 

1    User ID number    #    PIN #   

The  ID  number  is  any  number  between  1  &  2000.  The 

PIN  is  any  four  digits  between  0000  &  9999  with  the 

exception of 1234 which is reserved. Users can be added 

continuously without exiting programming mode 

To add a card user 

1    Read Card    # 

Cards  can  be  added  continuously  without  exiting 

programming mode 

To delete a PIN or a card user.   

2    User ID number    #    for a PIN user or       

2    Read Card    #    for a card user     

Users  can  be  deleted  continuously  without  exiting 

 


background image

 

programming mode 

To unlock the door for a PIN user 

Enter the PIN then press # 

To unlock the door for a card user 

Present the card   

3.  Description   

The  unit  is  single  door  multifunction  standalone  access  controller 

or

  a  Wiegand  output 

keypad  or  card  reader.  It  is  suitable  for  mounting  either  indoor  or  outdoor  in  harsh 

environments.  It  is  housed  in  a  strong,  sturdy  and  vandal  proof  Zinc  Alloy  electroplated 

case  which  is  available  in  either  a  bright  silver  or  matt  silver  finish. The  electronics  are 

fully potted so the unit is waterproof and conforms to IP68. This unit supports up to 2000 

users in either a Card, 4 digit PIN, or a Card + PIN option. The inbuilt card reader supports 

125KHZ  EM  cards,13.56MHz  Mifare  cards.  The  unit  has  many  extra  features  including 

lock output current short circuit protection, Wiegand output , and a backlit keypad. These 

features  make  the  unit  an  ideal  choice  for  door  access  not  only  for  small  shops  and 

domestic households but also for commercial and industrial applications such as factories, 

warehouses, laboratories, banks and prisons. 

4.  Features 

 

Waterproof, conforms to IP68   

 

Strong Zinc Alloy Electroplated anti-vandal case 

 

Full programming from the keypad 

 

2000 uses, supports Card, PIN, Card + PIN   

 

Can be used as a stand alone keypad 

 

Backlight keys 

 

Wiegand 26 input for connection to external reader 

 

Wiegand 26 output for connection to a controller             

 

Adjustable Door Output time, Alarm time, Door Open time   

 

Very low power consumption (30mA)   

 

Fast operating speed, <20ms with 2000 users 

 

Lock output current short circuit protection 

 

Easy to install and program 

 

Built in light dependent resistor (LDR) for anti tamper 

 

Built in buzzer 

 

Red, Yellow and Green LEDS display the working status 

 


background image

 

5.  Specifications   

 

Operating Voltage 

DC 12V

±

10%

 

User Capacity 

2000 

Card Reading Distance 

3-6 cm 

Active Current 

60mA 

Idle Current 

25±5 mA 

Lock Output Load 

Max 3A 

Alarm Output Load 

Max 20A 

Operating Temperature 

-45

℃~

60

 

Operating Humidity   

10%- 90% RH 

Waterproof 

Conforms to IP68 

Adjustable Door Relay time 

0 -99 seconds 

Adjustable Alarm Time 

0- 3 minutes 

Wiegand Interface 

Wiegand 26 bit 

Wiring Connections 

Electric Lock, Exit Button, External Alarm,External reader 

6.  Installation 

 

Remove the back cover from the keypad using the supplied special screw driver 

 

Drill 2 holes on the wall for the Self tapping screws and I hole for the cable 

 

Put the supplied rubber bungs to into the two holes 

 

Fix the back cover firmly on the wall with 2 Self tapping screws 

 

Thread the cable through the cable hole 

 

Attach the keypad to the back cover.

 

 

 

 

 


background image

 

7.  Wiring 

Colour 

Function 

Description 

Pink 

BELL_A 

Doorbell button one end 

Pale blue 

BELL_B 

Doorbell button to the other end 

Green 

D0 

WG output D0 

White 

D1 

WG output D1 

Grey 

ALARM 

Alarm negative(alarm positive connected 12 V+) 

Yellow 

OPEN 

Exit button one end(the other end connected GND) 

Brown 

D_IN 

Magnetic switch one end(the other end connected GND) 

Red 

12V+ 

12V + DC Regulated Power Input 

Black 

GND 

12V - DC Regulated Power Input 

Blue 

NO 

Relay normally-on end(Connect positive electric lock "-") 

Purple 

COM 

Relay Public end, connect GND

 

Orange 

NC 

Relay Closed end(connect negative electric lock "-") 

 

Magnetic lock and Fail-Safe lock diagram:   

                 

 

 

 


background image

 

 

 

 

 

Electric Strike and Fail-Secure wiring diagram: 

 

8.  To Reset to Factory Default 

            a. Disconnect power from the unit 

            b. Press and hold # key whilst powering the unit back up 

            c. On hearing two 

“Di” release # key, system is now back factory settings 

             

Please note only installer data is restored, user data will not be affected 

9.  Anti Tamper Alarm 

The  unit  uses  a  LDR  (light  dependent  resistor)  as  an  anti  tamper  alarm.  If  the  keypad  is 

removed from the cover then the tamper alarm will operate.   

10.Sound and Light indication 

Operation Status 

Red Light 

Green Light 

Yellow Light 

Buzzer 

Power on 

Bright 

Di 

Stand by 

Bright 

Press keypad 

Di 

Operation successful 

Bright 

Di 

 


background image

 

Operation failed 

DiDiDi 

Enter into programming mode 

Bright 

 

In the programming mode 

Bright 

Di 

Exit from the programming 

mode 

Bright 

Di 

Open the door 

Bright 

Di 

Alarm 

Bright 

Alarm 

 

11. Detailed Programming Guide   

11.1  User Settings 

To enter the programming mode 

  *    Master code # 

  999999 is the default factory master code   

To exit from the programming mode 

  *   

Note that to undertake the following programming the master user must be logged in 

To change the master code 

  0    New code    #    New code # 

The master code can be 6 to 8 digits long 

Setting the working mode: 

Set valid card only users 

Set valid card 

and

 PIN users 

Set valid card 

or

 PIN users 

       

  3      0      #

   

Entry is by card only

 

  3      1      #

   

Entry is by card 

and

 PIN together

 

  3      2      #

   

Entry is by either card 

or

 PIN (default)

 

To add a user in either card or PIN mode, i.e. in the 3      2      #    mode. (Default setting) 

To add a 

Pin

 user 

1    User ID number    #    PIN #   

The  ID  number  is  any  number  between  1  &  2000.  The 

PIN  is  any  four  digits  between  0000  &  9999  with  the 

exception of 1234 which is reserved. Users can be added 

continuously  without  exiting  programming  mode  as 

follows: 

1    User ID no 1 #    PIN # User ID no 2 #    PIN # 

To delete a 

PIN

 user 

2    User ID number    #     

Users  can  be  deleted  continuously  without  exiting 

programming mode 

To change the 

PIN

 of a PIN user   

(This  step  must  be  done  out  of 

  *    ID number #    Old PIN #    New PIN #    New PIN # 

 


background image

 

programming mode) 

To add a 

card

 user (Method 1) 

This  is  the  fastest  way  to  enter  cards, 

user ID number auto generation. 

1    Read card    # 

Cards  can  be  added  continuously  without  exiting 

programming mode 

To add a 

card

 user (Method 2) 

This is the alternative way to enter cards 

using User ID Allocation. In this method a 

User  ID  is  allocated  to  a  card.  Only  one 

user ID can be allocated to a single card. 

1      ID number    #    Read card    # 

User  can  be  added  continuously  without  exiting 

programming mode 

To add a 

card

 user (Method 3) 

Card  number  is  the  last  8  digits  printed 

on  the  back  of  the  card,user  ID  number 

auto generation 

1    Card number    # 

  User  can  be  added  continuously  without  exiting 

programming mode 

To add a 

card

 user (Method 4) 

In this method a User ID is allocated to a 

card  number.  Only  one  user  ID  can  be 

allocated to the card number 

 

  1      ID number. #    Card number. #   

User  can  be  added  continuously  without  exiting 

programming mode

 

To delete a 

card

 user by card. Note users 

can  be  deleted  continuously  without 

exiting programming mode 

2      Read Card        #   

To  delete  a 

card 

user  by  user  ID.  This 

option can be used when a user has lost 

their card 

2      User ID      #   

 

To delete a 

card

 user by card number. 

This  option  can  be  used  when  the  user 

want  to  make  the  change  but  the  card 

has lost 

2      Card number        #   

Note  users  can  be  deleted  continuously  without 

exiting programming mode 

To add a 

card and PIN

 user in card and PIN mode (3      1      #

 

)

 

To Add a 

card

 and 

Pin

 user 

(The PIN is any four digits between 0000 

& 9999 with the exception of 1234 which 

is reserved.) 

Add the card as for a card user   

Press 

  *

 to 

exit from the programming mode 

Then allocate the card a PIN as follows: 

  *    Read card 1234 # PIN # PIN # 

 


background image

 

To  change  a 

PIN 

in  card  and  PIN  mode 

(Method 1) Note that this is done outside 

programming  mode  so  the  user  can 

undertake this themselves

 

  *    Read Card    Old PIN #      New PIN #      New PIN # 

 

To  change  a 

PIN 

in  card  and  PIN  mode 

(Method 2) Note that this is done outside 

programming  mode  so  the  user  can 

undertake this themselves

 

  *    ID number #    Old PIN #      New PIN #    New PIN # 

 

To delete a 

Card and

 

PIN 

user just delete 

the card

 

2      User ID      # 

To add a 

card 

user in card mode (3      0      #

 

To Add and Delete a 

card

 user 

The operating is the same as adding and deleting a card 

user in 3      2      # 

To delete 

All users

 

To  delete

  ALL  users. 

Note  that  this  is  a 

dangerous

 option so use with care

 

2      0000      # 

To unlock the door 

For a 

PIN

 user 

Enter the PIN    then press # 

For a 

card

 User 

Read card 

For a 

card and PIN

 user 

Read card

 

then enter

 

PIN # 

 

 


background image

 

10 

11.2   

Door Settings 

Relay Output Delay Time

 

To set door relay strike time 

 

Master code

 

#

 

  4      0

99      #

 

0-99 is to set the door relay time 0-99 seconds 

Door Open Detection   

Door  Open  Too  Long  (DOTL)  warning

.  When  used  with  an  optional  magnetic  contact  or  built-in 

magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside 

buzzer  will beep  automatically  to remind  people to close the door and continue  for 1 minute before 

switching off automatically. 

Door Forced Open warning. 

When used with an optional magnetic contact or built-in magnetic contact 

of the lock, if the door is forced open, or if the door is opened after 20 seconds ,the inside buzzer and 

alarm  output  will  both  operate.  The  Alarm  Output  time  is  adjustable  between  0-3  minutes  with  the 

default being 1 minute.

 

To  disable  door  open  detection.  (Factory 

default) 

  6      0      # 

To enable door open detection 

  6      1      # 

Alarm output time

 

To set the alarm output time (0-3 minutes) 

Factory default is 1 minute   

  5      0

3      #

 

Keypad Lockout & Alarm Output options

If there are 10 invalid cards or 10 incorrect PIN numbers 

in a 10 minute period either the keypad will lockout for 10 minutes or  both the alarm and the inside 

buzzer will operate for 10 minutes, depending on the option selected below.

 

Normal  status:  No  keypad  lockout  or 

alarm (factory default) 

  7      0      # (Factory default setting) 

Keypad Lockout 

  7      1      # 

Alarm and inside buzzer operate     

  7      2      # 

To remove the alarm

 

To reset the Door Forced Open warning 

Read valid card

 or 

Master Code # 

To reset the Door Open Too Long warning  Close the door 

or 

  Read valid card

 or 

Master Code # 

 

 


background image

 

11 

 

 

12.The unit operating as a Wiegand Output Reader 

In  this  mode  the  unit  supports  a  Wiegand  26  bit  output  so  the  Wiegand  data  lines  can  be 

connected to any controller which supports a Wiegand 26 bit input.