PDF User Manual

  1. Home
  2. Manuals
  3. LG MB8811C1 User Manual

LG MB8811C1 User Manual

Made by: LG
Type: User Manual
Category: Control Unit
Pages: 10
Size: 0.66 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Bluetooth Module : MB8811C1 

 

 

       

 

  [top]                                          [bottom] 
 
This MB8811C1 Module is compatible with Bluetooth specification version 4.0. MB8811C1 is a fully integrated RF, 
baseband controller etc.

 

 

 

SPECIFICATION 

 

Main Chips 

CSR8811 

Standards 

Bluetooth 4.0

+BLE 

 

Frequency Band 

2402 ~ 2480 MHz 

Tx Power 

7

mW

 

Rx Sensitivity 

< -70dBm (BER 0.1%) 

Distance 

< 10m (open space) 

Power Voltage 

3.3V 

Dimension 

18.6

31.2 

3.4 mm 

Environmental Range 

Operation temperature : -10 ~ +70

 

 

Modulation mode 

  GFSK, 8DPSK

≤κ

/4 DQPSK

 

Communication method 

  FHSS 

 
 
 
 
 
 
 

 


background image

Pin define(TOP PIN MAP) 

 

No 

Pin Name 

I/O 

Description 

CTS 

Bluetooth UART Clear to Send.Active-low clear. 

VDD 

Positive Input for the internal regulator (3.0 ~ 3.6V) 

TXD 

Bluetooth UART Serial Output. 

RTS 

Bluetooth UART Request to Send. 
Active-low request. 

RXD 

Bluetooth UART Serial Input. 

6,7,8,12 

GND 

Ground. 

SDA 

I/O  I2C interface DATA 

10 

SCL 

I2C interface Clock 

11 

RESET 

Reset if low. Input debounced so must be low for >5ms to 
cause a reset 

 
 
 

 

 

1. VDD

2.RESET

3.RTS

4.CTS

5.TXD

6.GND

7.RXD

8.GND

9. SCL

10. SDA

 

 


background image

 

Pin define(BOTTOM PIN MAP) 
 

No 

Pin Name  I/O 

Description 

CTS 

Bluetooth UART Clear to Send.Active-low clear. 

VDD 

Positive Input for the internal regulator (3.0 ~ 3.6V) 

TXD 

O  Bluetooth UART Serial Output. 

RTS 

O  Bluetooth UART Request to Send. 

Active-low request. 

RXD 

Bluetooth UART Serial Input. 

6,7,8,12 

GND 

Ground. 

SDA 

I/O  I2C interface DATA 

10 

SCL 

O  I2C interface Clock 

11 

RESET 

Reset if low. Input debounced so must be low for >5ms to 

cause a reset 

2. VDD

11.RESET

4. RTS

1. CTS

3. TXD

5. RXD

6. GND

10. SCL

9. SDA

8. GND

7. GND

12. GND

 

 

 

 

 


background image

Dimension 

 

                               

 

Mark 

Dimension  Mark  Dimension  Mark 

Dimension 

Mark 

Dimension 

Mark 

Dimension 

18.60±0.3 

3.90±0.2 

2.0±0.2 

6.4±0.2 

3.4±0.2 

31.20±0.3 

8.40±0.2 

1.9±0.2 

4.9±0.2 

5.0±0.2 

9.70±0.3 

2.0±0.3 

0.8±0.1 

2.6±0.2 

5.1±0.2 

                                                                                                                                                              (Unit : mm) 

 

 

 


background image

Electrical Characteristics 

 

Conditions    : VDD = 3.3V,    Ta = 25 

, unless otherwise noted. 

 

Absolute Maximum Ratings 
Parameter 

Min 

Max 

Unit 

Power Supply Voltage : VDD 

-0.4V 

3.6V 

DCV 

Storage Temperature 

-40 

85 

℃ 

 
Recommended Operating Conditions 

Parameter 

Min 

Max 

Unit 

Power Supply Voltage 

3.0V 

3.6V 

DCV 

Operation Temperature 

-10 

70 

 

 

Current consumption 

Parameter 

Connection Type 

Avg 

Peak 

Unit 

Page scan, Time interval = 1.28s 

 

mA 

Inquiry and Page scan, Time interval = 1.28s 

mA 

ACL No data transfer 

Master 

10 

 

mA 

ACL data transfer 

Master 

32 

 

mA 

 

Input/Output Characteristics 

Parameter 

Min 

Max 

Unit 

V

IL 

Input Voltage Low 

-0.4 

0.8 

V

IH 

Input Voltage High 

0.7*VDD 

VDD+0.4 

V

OL 

Output Voltage Low 

0.2 

V

OH 

Output Voltage High 

VDD-0.2 

 
 

 

 


background image

 

General Performance 

Parameter 

Condition 

Min 

Typ 

Max 

Unit 

Frequency Range 

Normal 

2402 

2480 

MHz 

 

Transmitter Performance 

Parameter 

Condition 

Min 

Typ 

Max 

Unit 

Transmit Power 

Normal 

-6 

dBm 

Power density 

Normal 

20 

dBm 

20dB bandwidth 

Normal 

 

 

1000 

KHz 

Adjacent channel power 

(F

0

 = 2441MHz) 

F=F

±2MHz 

-20 

dBm 

F=F

±3MHz 

-40 

dBm 

F=F

±4MHz 

-40 

dBm 

Out-band Spurious Emission 

30MHz ~ 1GHz 

-36 

dBm 

1GHz ~ 12.75GHz 

-30 

dBm 

1.8GHz ~ 1.9GHz 

-47 

dBm 

5.1GHz ~ 5.3GHz 

-47 

dBm 

Modulation Characteristic 

∆F1

avg

 

140 

175 

KHz 

∆F2

max

 

115 

KHz 

∆F2

avg 

/ ∆F1

avg

 

80 

Initial Carrier Frequency 

Tolerance 

DH1 packet 

-75 

75 

KHz 

Carrier Frequency Drift 

DH5 packet 

-25 

 

25 

KHz 

 

Receiver Performance 

Parameter 

Condition 

Min 

Type 

Max 

Unit 

Sensitivity at 0.1% BER 

Single slot (DH1 packet) 

-70 

dBm 

Sensitivity at 0.1% BER 

Multi slot (DH5 packet) 

-70 

dBm 

Maximum received signal at 0.1% BER 

 

-20 

dBm 

Maximum level of intermodulation 

interferers 

  f1-f2 = 5 MHz, Pwanted= -64 

dBm 

-39 

dBm 

 
 

 

 


background image

MB8811C1 Test Manual

 

 

1)

 

RF Test Utility 

2)

 

First time, CSR Bluesuite program must be installed. you can use BTCli.exe and enter 
DUT(Device Under Test) mode. So RF equipment can inquiry and test. (reference 
document.) 

 
* reference document : MB8811C1_JIG_Bluetest3 setting manual.pdf 
 

3)

 

RF Test method 

RF Test tool is BlueTest.exe at CSR bluesuite program. You can see detail explanation 
from reference document. 

 
* reference document : BlueTest Instruction Manual.pdf 

 
 
Conformity Assessment Display 
Company name

: M

CSLogic 

Model 

: MCS Bluetooth Smart Device Module (MB8811C1) 

Manufacture Year 

: 2014. . 

Manufacturer 

/ Manufacture Country : M

CSLogic 

Korea 

 

Operation of the radio equipment may cause propagation interference, and so the life-saving 

services could not be

 

 

 


background image

                                                                 

   

 

 

 

STATEMENT and Warning 

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 

conditions: (1) This device may not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause undesired operation. 

FCC Caution: Any changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate this equipment. 

   

This transmitter must not be co-located or operating in conjunction with any other antenna or 

transmitter. 

 

FCC RF Radiation Exposure Statement 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled 

environment. This equipment should be installed and operated with minimum distance 20cm 

between the radiator & your body. 

 

IC 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject 

to the following two conditions: (1) this device may not cause interference, and (2) this device 

must accept any interference, including interference that may cause undesired operation of the 

device. 

This equipment complies with IC radiation exposure limits set forth for an uncontrolled 

environment. This equipment should be installed and operated with minimum distance 20cm 

between the radiator and your body. 

French: 

Cet appareil radio est conforme au CNR-210 d’Industrie Canada. L’utilisation de ce dispositif est 

autorisée seulement aux deux conditions suivantes : (1) il ne doit pas produire de brouillage, et (2) 

l’utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce 

brouillage est susceptible de compromettre le fonctionnement du dispositif. 

Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un 

environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 

cm de distance entre la source de rayonnement et votre corps. 

 

 


background image

                                                                 

19-1, Cheongho-ri Jinwi-myeon, Pyeongtaek-si,Gyeonggi-do, 451-713, Korea 

   

 

 

 

NCC 

「依據低功率電波輻射性電機管理辦法   

第十二條 

經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均 

不得擅自變更頻率、加大功率或變更原設計之特性及功能。 

第十四條 

低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干 

擾現象時,應立即停用,並改善至無干擾時方得繼續使用。 

前項合法通信,指依電信法規定作業之無線電通信。 

低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機 

設備之干擾。」 

 

任一平台若裝置本模組,其平台標籤須標示

  “

內建藍芽模組

 NCC:XXXXXXXXXXX”

 

 

This device is intended only for OEM integrators under the following conditions: 

 

 

The antenna must be installed such that 20 cm is maintained between the antenna 

and users, and   

 

The transmitter module may not be co-located with any other transmitter or antenna.   

 

As long as 2 conditions above are met, further transmitter test will not be required. However, the 

OEM integrator is still responsible for testing their end-product for any additional compliance 

requirements required with this module installed 

 

IMPORTANT NOTE:

 In the event that these conditions can not be met (for example certain 

laptop configurations or co-location with another transmitter), then the FCC authorization is no 

longer considered valid and the FCC ID cannot be used on the final product. In these 

circumstances, the OEM integrator will be responsible for re-evaluating the end product 

(including the transmitter) and obtaining a separate FCC authorization. 

 

 

 

 

 

 

 

 

 

 

 

 


background image

                                                                 

19-1, Cheongho-ri Jinwi-myeon, Pyeongtaek-si,Gyeonggi-do, 451-713, Korea 

   

 

 

 

End Product Labeling 

This transmitter module is authorized only for use in device where the antenna may be installed 

such that 20 cm may be maintained between the antenna and users. The final end product 

must be labeled in a visible area with the following: “Contains FCC ID: BEJ9QK-DMMB8811C

1

”, 

“contains IC: 2703H-DMMB8811C

1

”. The grantee's FCC ID can be used only when all FCC/ IC 

compliance requirements are met. 

 

 

Manual Information To the End User 

The OEM integrator has to be aware not to provide information to the end user regarding how to 

install or remove this RF module in the user’s manual of the end product which integrates this 

module. 

 

CE  

Hereby declares that this WiFi module is in compliance with the essential requirements and 

other relevant provisions of R&TTE Directive 1999/5/EC. The standards for complying are as 

following: 

ETSI EN 301 489-1 V1.9.2: 2011-09 

ETSI EN 301 489-17 V2.2.1: 2012-09 

ETSI EN 300 328 V1.8.1:2012-06 

EN 62311: 2008 

EN 60950-1: 2006 +A11:2009

+A1:2010+A12:2011+A2:2013

 

 

This is a class B product. In a domestic environment, this product may cause radio interference, 

in which case the user may be required to take adequate measures. 

This is a class B product. In a domestic environment, this product may cause radio interference, in 
which case the user may be required to take adequate measures.   

This device is intended for home and office use in all EU countries