PDF User Manual

  1. Home
  2. Manuals
  3. King Pigeon GSM 3G M2M RTU User Manual

King Pigeon GSM 3G M2M RTU User Manual

Made by: King Pigeon
Type: User Manual
Category: Security System
Pages: 15
Size: 1.09 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

GSM 3G 
IOT M2M 

Solution 
 

User Manual 

Ver 1.0     

S27x 

Date Issued: 2015-04-20 

All rights reserved by   

King Pigeon Comm.Co.,Limited. 

www.GSM-M2M.com

 

GSM 3G

 

M2M RTU

 

 


background image

 

 

 

    Page 2 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

 

Table of contents 

1.

 

Brief  introduction 

-------------------------------------------------------------------------------------------------4 

2.

 

Safety Directions

 ---------------------------------------------------------------------------------------------------6 

3.

 

Physical  Layout

 ----------------------------------------------------------------------------------------------------7 

4.

 

Settings

  ---------------------------------------------------------------------------------------------------------------8 

5.

  SMS commands & APP

-------------------------------------------------------------------------------------------9

 

6.

  Communication  Protocol

--------------------------------------------------------------------------------------13

 

7.

  Registers Assignment Table

----------------------------------------------------------------------------------14

 

8. 

Upgrade  Firmware  ------

----------------------------------------------------------------------------------------15

 

9. 

Warranty

  -----------------------------------------------------------------------------------------------------------15 

 

 

 

 

 

Model GSM/3G  Precision 

DIN  AIN 

DO 

Register 

Record 

Port 

S270 

12bit 

1000 

USB 

S271 

12bit 

1000 

 

S272 

12bit 

TF Card 

USB/RS232/RS485 

S273 

12bit 

64 

TF Card 

S275 

16bit 

64 

TF Card 

USB/RS232/RS485/RJ45 

Notice 

1.

 

For 3G Version, the model should plus C or W, C stands for inbuilt module is CDMA2000. W stands 
for inbuilt module is WCDMA; 

2.

 

All of them support 1 temperature and 1 humidity inputs for environment monitoring. 

3.

 

The standard package:   
1x RTU, 1x GSM Antenna, 1x AC/DC Adaptor,1x Android APP, 1x PC Configuration Software, 
1x USB cable, 1x User Manual, 1x Backup battery inside, 1x TF card inside, Terminals for Connection. 

4.

 

The standard package not includes: SIMCard , Temperature+Humidity sensor TH100 

Warning Tips: 

This User manual is for S275, for other models please refer to this user 

manual and note abovementioned differences. 

This handbook has been designed as a guide to the installation and operation of RTU S27x. 

Statements contained in the handbook are general guidelines only and in no way are designed to supersede the 

instructions contained with other products. 

We recommend that the advice of a registered electrician be sought before any Installation work commences. 

King Pigeon Communication.Co.,Limited. its employees and distributors, accept no liability for any loss or damage 

including consequential damage due to reliance on any material contained in this handbook.   

King Pigeon Communication.Co.,Limited. its employees and distributors, accept no liability for GSM Network 

upgrading or SIMCard upgrading due to the technology specifications contained in this handbook.

 

 


background image

 

 

 

    Page 3 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

1. Brief Introduction 

The GSM 3G M2M RTU inbuilts 

ARM® Cortex™ 32 Bit RISC Core, 168 MHz inside, RTOS system. It is a multi 

I/O  port  remote  terminal  unit,  through  the  RS232/485  port  can  extend  up  to  64  additional  I/O  or  connect 
intelligent meters or PLC. It is special for BTS monitoring, remote data acquisition, telemetry, BTS monitoring, 
access  control,  ATM,  generator  monitoring,  Pump  station  monitoring,  weather  satiation  monitoring  and  other 
applications. It supports voice communication, SMS, GPRS, 3G and RJ45 LAN IP communications.   
 
The GSM 3G M2M RTU can be used as remote access control. The authorized users can open the gate or turn 
on the machine with a free charge call at specified time. 
 
The GSM 3G M2M RTU supports Modbus RTU, Modbus TCP, TCP/UDP protocol, transparent data 
transmission over GPRS/3G, RS232, RS485, RJ45, performs as Modbus Master or Modbus Slave. It can 
integrate into present SCADA or DCS or HMI directly. 
 
The GSM 3G M2M RTU can be used as Modbus RTU SMS Alert Alarm, when the data acquisition from 
RS232/485 exceeds threshold value, it also can send pre-definition SMS to users. 
 

The GSM 3G M2M RTU can be used as: 

 

A Switch with SMS Remote Control

. SMS texts for switching particular terminals on/off are 

configurable.   

 

A Modbus RTU SMS Alarm

. It can be used as Modbus RTU SMS Alarm, when the data/value 

acquisition from RS232/485 exceed the threshold, it can send SMS to alert the users immediately. 

 

A Timer-Switch which can be activated automatically

. It can be used as preset time when the GSM 

3G M2M RTU 

need work and when it needn‘t work.   

 

An Access Control unit.

 Up to 10 tel. numbers can be authorized for dial to access control and open 

the electricity door directly with free charge. 

 

An automation system.

 Each input can link to output actions, this is very useful when the temperature 

upto appointed value, need switch on the air-conditioning immediately, or when water overflow and need 

switch on the dryer, or when somebody broken into the door or windows need to start the CCTV and 

Siren.   

 

A SMS reporter.

 The GSM 3G M2M RTU can setup daily automatically report its current status to users. 

 

A SMS Alarm Controller.

 The IO activations or deactivations can be reported by SMS and optionally 

confirmed by phone calls. Each input can have its own message texts and the message can be 

programmed by users.   

 

A Pulse Counter. 

The digital inputs can be used as the pulse counter, the user can setup both of interval 

value activated alarm and total value activated alarm. 

 

A Data Logger. 

The unit can save the all of the acquisition data in internal memory storage and upload 

to internet by GPRS /3G/RJ45/RS232/RS485 network according to schedue, no distance limitation.   

 

A Wireless Data Acquisition to SCADA or HMI or Monitoring Center. 

The unit can acquisition the 

varity data(E.g.: Pressure, Level, Current, Voltage, digital input status, pulse counter, digital relay output 

status, temperature value, humidity value and other) and upload to the SCADA(Real time dynamic data) 

or HMI or Monitoring Center by SMS/GPRS/3G/RJ45/RS232/RS485, no distance limitation. 

 

A Wireless Intelligent Meter Reader.

 The GSM 3G M2M RTU can be used to read remotely intelligent 

meter data to SCADA or monitoring center by RS232 port or RS485 Port. 

 


background image

 

 

 

    Page 4 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

 

A GSM 3G DTU(GPRS 3G Data Transfer Unit).

 It can work with the supervisioning center, in the 

supervisioning center, the own can remote monitoring and control the remotely terminals by 

GPRS/3G/RJ45 LAN Network.This is very useful to Fuel tank monitoring, Oxygen in hospital, Flood level, 

street light control, wellhead control, BTS environment monitoring, power transmission system 

monitoring and other applications. 

1.1 Typically Applications 

 

 
Typically BTS Solution Diagram: 

 

 


background image

 

 

 

    Page 5 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

 

A:

I/O  port  connections,  RS232/RS485  extend  I/O  ports,  RS232/RS485  connects  Air-Conditioners,  intelligent 

meters,  Diesel  Generator,  Power  System,  and  Battery  Groups  via  transparent  protocol  or  Modbus  RTU 
protocol. Under this condition, the RTU performs Modbus RTU Master;   

B:

Through RJ45 LAN cable or GPRS or 3G to HMI, OMC, the protocol is defined by user of personal.   

C:

 Through RJ45 LAN cable or GPRS or 3G to SCADA,HMI, DCS, OPC Server, Under this condition, the RTU 

performs Modbus Slave.   

      Through  RS232  or  RS485  to  SCADA,  HMI,  DCS,  OPC  Server,  under  this  condition,  the  RTU  performs 

Modbus Slave. 

D:

Through SMS to control RTU, or receive SMS alarm alert, or through voice communication to open the door 

or receive alarm calling. 

 

1.2 Mainly Features 

1) 

ARM® Cortex™-M4 32 Bit RISC Core, 168 MHz inside, RTOS system; 

2)  Widely Rated voltage range, 9~36VDC, Inbuilt large capacity rechargeable backup battery; 

3)  2G TF card for save historical data, USB port for configuration and upgrade firmware; 

4)  6 analog inputs, 16bits, supports 0-5V, 0-20mA, 4-20mA; 

5)  4 Relay outputs, 5A/30VDC,5A/250VAC; 

6)  8 digital inputs, dry contact or level input. One of the input can be used as counter; 

7)  1 temperature probe input, 1 humidity transducer input; 

8)  I/O ports with opto-isolated, RS232/485 with 15KV ESD protection; 

9)  2 IP data centers, supports Modbus TCP,TCP/IP protocol over GPRS/3G/RJ45 LAN network; 

10)  RS232/RS485 can performs Modbus RTU Master, Modbus RTU Slave, supports 01,02,03,04,05 code, up 

to 64 registers, the register arise alarm also can send SMS to alert; 

11)  RS232/485 can be used as data transparent transmission for different intelligent meters or PLC; 

12)  Automatically resend the data while communication failure, GPRS failure will alert by SMS text; 

13)  Supports remotely restart the RTU, and configure it by SMS commands remotely; 

14)  Supports over voltage protection and phase-reversal protection; 

15)  10 SMS Alert and auto dial numbers, can program to receive specified alarm message. 

16)  10 access control authorized numbers, can open the BTS door or turn on/off machine with a free charge call 

at the specified time. 

 

1.3 Specifications 

   

   

Item 

Reference Scope 

DC Power supply 

Standard adapter: DC 12V/1.5A    Range 9-36VDC 

Power consumption 

Standby:12V/70mA;    Working Max.: 12V/300mA 

GSM/3G Frequency 

850/900/1800/1900Mhz/3G(WCDMA or CDMA2000) 

 


background image

 

 

 

    Page 6 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

Transmit power 

Class 4 (2W) at EGSM 900 and EGSM 850 
Class 1 (1W) at GSM 1800 and GSM 1900 

GPRS connectivity 

GPRS multi-slot class 10 

GPRS Data Transmission 

GPRS data downlink transfer: max. 85.6 kbps 
GPRS data uplink transfer: max. 42.8 kbps 
Coding scheme: CS-1, CS-2, CS-3 and CS-4 

TCP/IP stack 

TCP,UDP 

SIM interface 

Supporting 3V /5V SIM Card 

External antenna 

SMA Antenna interface, 50 Ohm 

Serial Interfaces 

1 USB Port; 

Protocols 

SMS, GPRS UDP,TCP, Modbus RTU, Modbus TCP and more equipment 
protocols can be added according to requirements. 

RS232/485 

1 RS232 and 1 RS485, Support Transparent transmission and Modbus RTU 
Master, Modbus RTU Slave. 

RJ45 Port 

1 Port, for LAN IP communication 

Wireless Module 

433Mhz, DSSS, 3-5Km or 6-10Km.(Only Special Model support it) 

Digital Inputs 

8 Digital input, NC/NO/Edge/Level type, Can be used as Pulse Counters; 

Analog Inputs 

6 Analog Inputs. 12 bit resolution, 0-5V or 0-20mA or 4-20mA; 

Temp.&Hum Inputs 

TH100, Range: Temperature: -40°C to +80°C, Humidity: 0~100%RH; 

Relay Outputs 

4, Rated: 5A/30VDC,5A/250VAC 

Power Outputs 

2 Port, for external device. 

Memory Capacity 

Internal Memory inside, can save the data for 1000events. 

Backup Battery 

3.7V 1200mAH 

Temperature range 

-10-+70 °C 

Humidity range 

Relative humidity 95% (condensation free) 

Exterior dimension 

168mm*113mm*32.3mm 

Net Weight 

1000 g 

2.Safety Directions 

Safe Startup 

Do not use unit when using GSM/3G equipment is prohibited or might bring disturbance or danger.   

 

Interference 

All wireless equipment might interfere network signals of unit and influence its performance. 

 

 

Avoid Use at Gas Station 

Do not use unit at a gas station. Power off Gate Opener when it near fuels or chemicals. 

 

Power it off near Blasting Places 

Please follow relevant restrictive regulations. Avoid using the device in blasting places. 

 

 

Reasonable Use 

Please install the product at suitable places as described in the product documentation. Avoid 

signal shielded by covering the mainframe. 

 

Use Qualified Maintenance Service

 

Maintenance can be carried out only by qualified maintainer. 

 

 

 

 


background image

 

 

 

    Page 7 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

3. Physical Layout 

 

LED Indicator

 

Power 

The Power status indicator, when power on the LED will turn normally on. 

Signal 

GSM/3G signal indicator, GPRS Connective successful will slowly flick. 

Alarm 

Alarm Indicator, on is alarming, off is normally; 

Arm 

GPRS Receiving data is on, otherwise is off. 

Run 

 

RS232 

RS232 Port communication indicator, normally is off; 

RS485 

RS485 Port communication indicator, normally is off; 

T/H 

Temperature & Humidity sensor TH100 inputs. 

Power Connector Definition 

 

DC IN+ 

External Power Connector, Connect to 1.5A@9~36V DC power through AC/DC Adaptor, 
positive electrode. 

DC IN- 

External Power Connector, negative electrode. 

DC Out 

See above mentioned photo. 

Digital Relay Output Connector Definition 

DO + 

Digital Relay Output 4+, positive electrode, NO; 

GND 

Digital Relay Output 4-, negative electrode. 

COM Port Connector Definition 

485A 

485A 

485B 

485B 

RST 

RST

RS232 CONTORL

 

TXD 

TXD(RS232) 

RXT 

RXD(RS232) 

GND 

GND 

USB Port Connector Definition 

USB 

USB port, for configuration and upgrade firmware and output historical data; 

ATN Port Connector Definition 

 


background image

 

 

 

    Page 8 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

ATN 

GSM/3G Antenna connector, 50Ohm, SMA female. 

Analog Input Connector Definition 

GND 

GND, Analog negative electrode 

AIN+ 

Analog input, positive electrode. 

       

 

Digital Input Connector Definition 

GND 

Opto-isolated digital input, negative electrode. 

DIN+ 

Opto-isolated digital input, positive electrode.( Level >3.3V as Close, <=3.3V as Open) 

 
4. Setting 
 

The GSM 3G M2M RTU is user-friendly design. The user can setup it or export historic data by the PC 

Configurator through USB cable, and upgrade firmware by USB port. The GSM 3G M2M RTU also can be 

configured some parameters by SMS Commands or Android APPs. 

Step1:    Install USB Drvier 

Please Contact the unit to the PC by USB Cable, and then install the USB Driver to the computer from the 

CD firstly. When successful, it can be found out at the device manager of the XP or Windows 7, please 

see the below photo. Also, the driver for different OS can be downloaded from Silicon Laboratories, Inc. 

http://www.silabs.com

 , the model is CP210x. 

 

Step2:    Connection 

Please insert the SIMCard, and install the GSM/3G Antenna, then contact the additional detectors or 

transducers or meters to the units, and finial connect the power to the GSM 3G M2M RTU and power on 

it.(For Analog input, please reference the interface part to choose the correct input type for 0-5V and 

0-20mA or 4-20mA). 

Step3: Install the GSM 3G M2M RTU Configurator 

Mode switch: 

SET: 

for configuration by PC 

software 

RUN: 

for regular working status   

 

Analog Input Type switch 

mA: 

Stands for 4-20mA 

transducers; 

V: 

stands for 0-5V transducers. 

 


background image

 

 

 

    Page 9 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

The GSM 3G M2M RTU Configurator in the CD or download from 

www.GSM-M2M.com

, then install it on 

the computer. 

Step3: Run the GSM 3G M2M RTU Configurator 

Connect the PC and GSM 3G M2M RTU by USB Cable, then click 

  to run it. Enter the password, 

default is 1234. Then you can enter the configuration page as below: 

 

Step4: Configuration Parameters 

The GSM 3G M2M RTU configurator is a user friendly design software, all of the parameters and ranges 

are describe clearly, please read the notices carefully to save you configuration time. Also for daily operate, 

we are strongly recommend the user use the App.   

 

 

5. SMS commands & APP 

The user can send SMS commands to setup or operate the GSM 3G M2M RTU, also can use the APP to 

control it easier.   

1.  Click Read the Computer time 

2.  Click Write the RTU time 

3.  Click Read the RTU time 

Click it to save the settings 

 


background image

 

 

 

    Page 10 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

 

The SMS commands are below: 

1)

 

Commands error return SMS 
 

Event 

Return SMS Content 

Any incorrect Command 

SMS Format Error, Please check Caps Lock in Command! 

2)

 

External DC Status 

Event 

Return SMS Content 

External DC goes off 

External DC Power Goes OFF 

External DC Power Goes ON   

External DC Power Goes ON 

3)

 

Modify Password, 4digits, default is 1234 

SMS Command 

Return SMS Content 

Old Password

P

New Password 

This is the New Password, please remember it carefully. 

4)

 

Arm/Disarm SMS Command 

SMS Command 

Return SMS Content 

Arm 

password+AA 

Armed 

Disarm 

password+BB 

Disarmed 

5)

 

Set RTU time, format is 2015-05-22 15:20:30W01, the W01 stands for Monday, W07 stands for Sunday. 

SMS Command 

Return SMS Content 

password+DxxxxxxxTxxxxxWxx 

xxxx(Y)XX(M)XX(D)xx(H)X(M)xx(W) 

 


background image

 

 

 

    Page 11 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

6)

 

Inquiry Current Status SMS Command 

SMS Command 

Return SMS Content 

password+EE 

Armed/Disarmed 

Model: 

Version: 

IMEI: 

GSM Signal Value: 

External DC Power Goes OFF/ON 

7)

 

Setup 10 User number(Alarm Number&Access Control Number), max 21digits. ( Return 0~4 or 5~9 separately 
while setting.) 

SMS Command 

Return SMS Content 

Setup 

password

A

series number+T+tel number 

 

Notice: 

Series number = 0~9 

Tel1: --- 

Tel2: --- 

Tel3: 13570810254 

Tel4: --- 

Tel5: --- 

Inquiry 

password+A 

Return all numbers 

Delete 

password+A+series number 

Return 0~4 or 5~9 numbers. 

8)

 

Authority User Number to access control: authorized number can dial to disarm and open the door. 

SMS Command 

Return SMS Content 

Setup 

Specified access control time: 

password

B

series number+S+start time+E+endtime 

Always can access control: 

password

B

series number+P 

Notice: 

Time format is 201505231230, stands for year, month, date, hour, minute. 

Tel1: --- 

Tel2: --- 

Tel3: 13570810254 

Tel4: --- 

Tel5: --- 

Inquiry 

password+B 

Return all authorized user numbers 

Delete 

password+B+series number 

Return all authorized user numbers

 

 

9)

 

Setup Daily Report time 

SMS Command 

Return SMS Content 

Setup 

password+DR+series number+T+time 

Notice:   

Series number =0~9, e.g.: 1234DR1T12:30 

Daily SMS Report at: xx:xx 

Inquiry 

password+DR 

 

Delete 

password+DRDEL 

 

10)

 

Setup DIN Name(For recovery alert then the SMS will plus “Recovery”) 

SMS Command 

Return SMS Content 

Set DIN Name 

password+DIN+channel number+T+ DIN Name 

Notice: 

channel number= 0~7, DIN Name max 40 characters; 

E.g.: 1234DIN0TDoor alarm 

DINx: 

Inquiry DIN Name 

password+DIN+series number<nnnnnnnn> 

Notice:   

nnnnnnnn stands for channel number 

 

Delete DIN Name 

password+DIN+series number+DEL 

 

Inquiry Status   

password+DINE 

DIN1:Open/Close 

DIN2: Open/Close 

----- 

 


background image

 

 

 

    Page 12 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

11)

 

Setup AIN Name(For recovery alert then the SMS will plus “Recovery”) 

SMS Command 

Return SMS Content 

Set AIN Name 

password+AIN+channel number+T+AIN Name 

Notice: 

channel number= 0~5, AIN Name max 40 characters; 

E.g.: 1234AIN0TDoor alarm 

AINx:xxxx 

Inquiry AIN Name 

password+AIN+ channel number<nnnnnnnn>   

 

Delete AIN Name 

password+AIN+ channel number+DEL 

 

Set Threshold   

password+AINR+channel number+Lxxx+Hxxx 

AINx:    Low:xxx,High:xxx. 

Inquiry Threshold 

password+AINR+ channel number<nnnnnnnn>   

AINx:    Low:xxx, High:xxx. 

AINy:    Low:xxx, High:xxx. 

Delete Threshold 

password+AINR+ channel number+DEL 

 

Set AIN measurement   

range 

password+AINM+ channel number+Lxxx+Hxxx 

AINx: Min:xxx,Max:xxx 

Inquiry measurement 

range 

password+AINM+ channel number<nnnnnnnn>   

AINx: Min:xxx, Max:xxx. 

AINy: Min:xxx, Max:xxx. 

Delete  measurement 

range 

password+AINM+channel number+DEL 

 

Inquiry AIN Current 

Value 

password+AINE+channel number<nnnnnnnn>   

AINx

xxxx ,+

Normal/Higher/Lower

 

Inquiry All AIN Current 

Value 

password+AINE 

AIN0

xxxx ,+

Normal/Higher/Lower

 

AIN1

xxxx ,+

Normal/Higher/Lower

 

---- 

12)

 

SMS Control Digital Output 

SMS Command 

Return SMS Content 

Set DO Name 

password+DO+channel number+T 

DOx:xxxx 

Inquiry DO Name 

password+DO+ channel number<nnnn>   

 

Delete DO Name 

password+DO+ channel number+DEL 

 

Switch ON(Close) 

password+DOC+ channel number<nnnn>   

DOx: ON 

DOy:ON 

Switch OFF(Open) 

password+DOO+ channel number<nnnn>   

DOx: OFF 

DOy:OFF 

Inquiry  DO  Current 

Status 

password+DOE+ channel number<nnnn>   

DOx: ON/OFF 

DOy:ON/OFF 

Inquiry  all  DO  Current 

Status 

password+DOE 

DO1: ON/OFF 

DO2:ON/OFF 

--- 

Set Pulse Output time 

password+DOT+xxx                (3 digital, unit is seconds) 

Pulse Output Time:xxxS 

Inquiry  pulse  output 

time 

password+DOT 

Pulse Output Time:xxxS 

Pulse Ouput 

password+DOP+channel number<nnnn>   

No SMS Return 

13)

 

Set Server Parameter 

SMS Command 

Return SMS Content 

Set Server IP 

password+IP+ IPaddress+P+Com port 

Server: 

Port: 

Inquiry 

password+IP 

 

Delete 

password+IPDEL 

 

 


background image

 

 

 

    Page 13 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

14)

 

Set GPRS APN/USER NAME/PASSWORD 

SMS Command 

Return SMS Content 

Set   

password+AP+apn+#+username+#+userpassword 

APN: 

User Name: 

Password: 

Inquiry 

password+AP 

Delete 

password+APDEL 

15)

 

Wakeup GPRS Online 

SMS Command 

Return SMS Content 

password+GPRSonline

 

No SMS Return 

16)

 

Remote upload historic data via GPRS: Send this command, the unit will upload historic data via GPRS. 

SMS Command 

Return SMS Content 

password+HIS 

Automatically upload all historic data to server via GPRS. 

 

6. Communication Protocol 

The GSM 3G M2M RTU supports TCP/IP communication via GPRS/3G or RJ45 LAN, and RS232,RS485 serial 

ports for local communications. It is very useful for users to create remotely or local monitoring server. It inbuilt 

standard Modbus RTU, Modbus TCP, transparent data transmission protocol and definition protocol, the user 

can connect the GSM 3G M2M RTU to the present HMI, OPC Server, SCADA directly.   

 

6.1  Modbus RTU/Modbus TCP Protocol   

The GSM 3G M2M RTU supports standard Modbus RTU and Modbus TCP protocol, the user can use the 

standard Modbus RTU Server or Modbus TCP Server, e.g.: SCADA. The topological graphs please see 

below: 

RTU

Modbus

TCP Server

Modbus

RTU Server

Modbus

RTU meters 

or PLC or 

DAM

Modbus TCP

 

6.2  Definition Protocol 

The GSM 3G M2M RTU supports definition protocol to specified server. Usually the user should create its 

own server according to the definition protocol. The definition protocol please refer to <GSM 3G M2M RTU 

GPRS Definition Protocol> document. The topological graphs please see below: 

 


background image

 

 

 

    Page 14 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

RTU

Definition 

Server

Modbus

RTU Server

Modbus

RTU meters 

or PLC or 

DAM

Definition Protocol

 

6.3  Transparent Data Transmission 

The GSM 3G M2M RTU supports transparent data transmission via GPRS or 3G or RJ45 or RS232 or 

RS485 for non-standard meters or devices, e.g.: ATM device, air conditioner, generator, meters, 

instruments, transducers, sensors, PLC and so on. The user no need to create or change its present server 

protocol, and can use it directly. At this condition, the GSM 3G M2M RTU performs a SMS Alarm and SMS 

Controller and DTU and Modbus RTU Slave. The topological graphs please see below: 

RTU

Existing 

Server

Modbus

RTU Server

Non-

Modbus

RTU Meters 

or Devices

Transparent Data 
Transmission

 

7. Registers Assignment Table 

The registers assignment of the RTU and its IO will definite in the <GSM 3G M2M RTU Register Assignment 

Table>, please refer to it. 

 


background image

 

 

 

    Page 15 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

8.Upgrade Firmware 

The GSM 3G M2M RTU supports upgrade firmware via USB port directly. If there any new requirements 

should update the firmware, the user can upgrade them directly by USB port.  if you required upgrade, 

please contact us to modify the firmware according to you requirements, and we will provide the upgraded 

firmware to you to upgrade them. 

 

9. Warranty 

1)  The RTU is warranted to be free of defects in material and workmanship for one year from the date of 

purchase. 

2)  This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse by the 

Operating Instructions.