background image

 
 
 
 
 
 
 
 
 
 

Please read this booklet and keep for future reference for the safe 

installation of your: 

 

 
 

 

 

DRY MODEL  

 
 

FREESTANDING CLEAN AIR WOODBURNER 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

All installations must be in accordance with these instructions.  Consult 

with the building authority having jurisdiction to determine the need for a 

permit prior to commencing the installation.  Failure to follow these 

instructions may also void your fire insurance and warranty. 

 
 

This fire conforms with Ecan Requirements 

 


background image

Contessa AG Dry 

Please leave this manual with the owner when installation is 

complete. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INDEX 

 
 

 

Page No: 

 

Item No: 

Topic 

 

 

    3 

 

 

     1 

 

Warnings 

 

 

    4 

 

 

     2 

 

Installation Responsibilities 

 

 

    4 

 

 

     3 

 

Floor Protector Requirements 

 

 

    5 

 

 

     4 

 

Installation Clearances 

 

 

    6 

 

 

     5 

 

Assembly Instructions 

 

 

    7 

 

 

      

 

Fitting Seismic Restraints 

 

 

    8 

 

 

     6 

 

Flue Installation 

 

 

    9 

 

 

      

 

Minimum Height of Flue Exit 

 

 

    10   

 

 

 

Position of Triangular Baffles 

 

 

     

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Published 15/11/2012 

 


background image

Contessa AG Dry 

1.   WARNINGS 

 
THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL 
TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS. 
 
The 

Contessa AG

 is tested to N.Z. Standards AS/NZS 2918:2001. 

 
If this heater is incorrectly installed a house fire may result.  For your safety follow 
the installation instructions carefully.   
 
Do NOT connect the heater to a chimney serving another appliance. 
 
Although the exterior of the heater may appear cool, contact with the unit may cause 
burns, warn children and others of the possibility of injury should they touch the 
heater. 
 
Do NOT dry clothing or unseasoned wood directly in contact with the heater. 
 
Keep all household combustible materials at least 600mm away from front of the 
heater. This includes clothing, furniture, wood, newspaper, plastic, matches, etc. 
 

DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY 
OF THIS APPLIANCE WHEN IT IS OPERATING. 

 
Use caution when reloading with fuel.  Do NOT attempt to load fuel into the heater 
when the fire inside the stove is at or near its peak. 
 
Do NOT burn large quantities of paper or combustible material that would create an 
extremely hot/quick fire.   
 

USE ONLY DRY WOOD

.  AVOID BURNING WET OR GREEN WOOD. 

 
THE USE OF SOME TYPES OF PRESERVATIVE TREATED WOOD AS A FUEL 
CAN BE HAZARDOUS. 
TIMBER TREATED WITH COPPER CHROMIUM AND ARSENIC TYPE 
PRESERVATIVES WILL LEAVE TOXIC RESIDUES IN THE ASH, FIREBOX 
OR WITHIN THE FLUE; TIMBER OFFCUTS FROM BUILDING 
CONSTRUCTION WILL OFTEN CONTAIN BORIC SALTS.  THE 
COMBUSTION OF THIS MATERIAL OVER PROLONGED PERIODS CAN 
PRODUCE ADVERSE EFFECTS ON REFACTORY LINING IN SOLID FUEL 
APPLIANCES.  EMISSION OF POISONOUS GASES CAN ALSO BE 
EXPERIENCED WITH THE BURNING OF TREATED WOOD. 
 
Driftwood with salt content will also cause rapid deterioration of the heater and 
should not be used. 
 
 

 

 


background image

Contessa AG Dry 

2.   INSTALLATION RESPONSIBILITIES 

 

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE 
INSTALLED IN ACCORDANCE WITH AS/NZ 2918:2001 AND THE 
APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE 
OR CODES. 
 
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN 
APPROVED IN WRITING BY THE TESTING AUTHORITY IS 
CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR 
COMPLIANCE WITH AS/NZS 4013. 

 

CAUTION

:  MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS 

FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL 
SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS 
CONDITIONS.  WHERE SUCH ACTION IS CONSIDERED, THE 
MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE. 
 
Strict adherence to these instructions will meet these standards. 
Any variation from these installation instructions or any doubt about them must be 
checked against the requirements of the Standards. 
 
 

3.   FLOOR PROTECTOR REQUIREMENTS 

 
The heater should always be installed on top of its base due to high temperatures 
sustained over long periods.  The base must be anchored to both the floor protector 
and the floor for seismic restraint.  Anchor points are provided in the base or on the 
rear legs. 
 

PEDESTAL, DRAWER BASE & LEGS MODELS

 
If the heater is to be placed on or within 500mm of a heat sensitive floor, an

 

insulated

 

floor protector

 with a minimum thickness of 

40mm

 is required 

consisting of 20mm of an approved insulation material i.e. 2 sheets of 10mm 
micorboard or superlux, 10mm tile backing board and 10mm tiles or similar on the 
top surface. All joints on the upper surface should be sealed to prevent spilt ash from 
contacting any heat-sensitive material.  

 

 

 

 


background image

Contessa AG Dry 

4.   INSTALLATION CLEARANCES 

 
When installing the Contessa AG on a 

leg

 base 

ADD

 70mm

 to vertical measurements. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

If the heater is to be placed on or within 500mm of a heat sensitive floor an insulated floor protector will be required (page 4). 

 

 

HEATER MUST BE INSTALLED WITH A FLUE PIPE SHIELD 

 

CLEARANCES 

 

ON PEDESTAL 

OR DRAWER 

130* 

280 

420 

110 

100 

260* 

600 

420 

860 

1055* 

1380 

1200 

795 

600 

ON LEGS 

130* 

280 

350 

110 

100 

260* 

600 

420 

860 

985* 

1310 

1130 

725 

600 

 

*Clearances A, F & K can be reduced BY 30mm provided a Contessa cooktop grill is fitted to the fire. 

 

 


background image

Contessa AG Dry 

5.   ASSEMBLY INSTRUCTIONS 

 
1.   Remove all packaging and timber. 
 
2.   Remove parts from inside the firebox. 
 
3.   Position the base with angle steel down onto the floor protector, taking the 
necessary final clearance into consideration.  The base has the flue centre indicated on 
the anchoring bracket.  The label next to this point states the minimum clearances 
from the base to combustible surfaces.  These measurements coincide with the figures 
on page 4 for the heater clearances when assembled. 
 
4.   At this point a hole in the ceiling to accommodate the flue may be cut and the 
liners installed. 
 
5.   Remove both front and rear top castings. 
 
6.   Place firebox on base. 
 
7.   Check that the two triangular bricks on top of the baffles are sitting correctly – 
refer diagram on page 10. 
 
8.    Replace the rear top casting and refit the front top casting ensuring it fits neatly 
into the rear sealed channel. 
 
9.   Refit the stainless steel spigot in the top rear section of the firebox. 
 
10.  Assemble and fit flue as per instructions (page 8 & 9).  A flue shield must be 
fitted. 
 
11.  

If the option of reducing dimension A to 100mm

 was used 

 then the optional cooktop grill should be fitted on the top rear casting  
of the fire at this stage.   Secure to the rear heatshield on the fire with the 
bolts provided.                                         
 
12.  Secure the both the wood-burner and floor protector to the floor for seismic 
restraint as shown on page 7. DUE TO NZ BEING AN EARTHQUAKE PRONE 
COUNTRY, IT IS IMPORTANT TO ANCHOR THE CONTESSA DOWN IN 
CASE OF EARTH MOVEMENT. 
 
13.  Assemble and fit the gold/chrome plated or black rails. 
 
14.  Fit door knob. 

»»

 

 
15.  Fit the control knob - place the flat on the knob to  
the flat on the air control shaft situated on the right hand 
 side of the fire.  Press home firmly. 
 
 

 


background image

Contessa AG Dry 

 
 
 

FITTING SEISMIC RESTRAINT BRACKETS ON CONTESSA AG 

 

 
 
 
PEDESTAL OR DRAWER BASE MODELS 

 
 
 
 
 
1.   Remove bolts at rear of fire box 
2.   Fit Seismic Restraint brackets 
3.   Secure both the floor protector 
      and the appliance to the floor 
      using a dyna bolt or similar. 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
LEG MODELS 

 
 
 
 
 
 
1.   Place firebox on leg assembly 
      and fit brackets. 
2.   Locate as per appropriate clearances 
3.   Secure both the floor protector and the 
      appliance to the floor using a dyna 
      bolt or similar. 
 
 
 

 


background image

Contessa AG Dry 

6.  FREESTANDING FLUE SYSTEM 

INSTALLATION INSTRUCTIONS 

 
 
1.    Position heater on floor protector ensuring all heater  
       clearances are correct as per clearances on page 5. 
2.    Once the location is confirmed, the appliance and floor 
       protector shall be fixed to the floor itself (refer to   
       page 6 & 7). 
3.    Extend a plumb line from the centre of the fire flue pipe  
       spigot to the ceiling.  Mark position on ceiling and roof. 
4.    Trim hole and nog as required ensuring that a 25mm  
       safe clearance between combustible materials and flue 
       components is maintained.  Fix with non combustible  
       spacers and screws or clouts on all four sides. 
5.    Cut and frame (when required) an opening in the roof, 
       position the outer casing through the roof until it is flush 
       with the under side of the ceiling, making sure as with  
       the ceiling there is a 25mm safe clearance between  
       non-combustible materials and the flue components.  
       Fix as in step 4. 
6.    Fix appropriate flashing around outer casing to the  
       roof to ensure a weatherproof seal. 
7.    Assemble flue pipe sections ensuring all seams are in  
       line, the assembly is straight and crimped.  Ends are  
       pointing downwards.  Fix each joint with three stainless  
       rivets or self-tapping screws. 
8.    Place ceiling plate with folded edges upwards over  
       heater spigot. 
9.    Position the flue pipe into the heater spigot.  The flue  
       pipe can either lowered from the top as a single unit or  
       fed up from the room a length at a time, ensuring that  
       all joints are fixed properly. 
10.  Slide the inner casing into place, between the outer casing  
       and the flue pipe. 
11.  The flue pipe must extend 200mm above the outer casing. 
       Note:  Extra lengths of flue pipe, inner and outer casing 
      may be required to achieve the minimum clearance from  
      the roof. 
12.  Slide top spreader over flue pipe down into outer and inner  
      casing and tighten. 
13.  Slide cowl over flue pipe until it rests on spreader.  Secure 
      with rivets or self-tapping screws. 
14.  Fit rainhat.  Do not fasten as it must be removable for flue  
      pipe cleaning. 
15.  Fix ceiling plate to ceiling maintaining an even gap all around the flue pipe. 
      Note:  Ensure ceiling plate is spaced off from the ceiling with ceramic spacers supplied. 
 
CAUTION:  Mixing of appliance or flue system components from different sources or modifying the 
dimensional specifications of components may result in hazardous conditions.  Where such action is 
considered the manufacturer should be consulted in the first instance. 
WARNING:  The appliance and flue system shall be installed in accordance with AS/NZS 2918:2001 
and the appropriate requirements of the relevant building code or codes. 

 

 


background image

Contessa AG Dry 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 


background image

Contessa AG Dry 

10 

 

CONTESSA AG DRY 

IMPORTANT 

 

 
 
 
 

 

BAFFLES 

UPON 
INSTALLATION 
CHECK THAT 
THE TRIANGLE 
BRICKS ON TOP 
OF THE 
BAFFLES ARE 
PLACED AS 
SHOWN 

 


background image

Contessa AG Dry 

11 

FIRENZO

FIRENZO

FIRENZO

FIRENZO    

 

WOODFIRES 

 

by 

HEWITSONS LIMITED 

 

Manufacturers of: 

Lady Kitchener  

Contessa 

Coaster 

Bronte 
Royale 

Viking 

Encore 

Zealandia 

Aqualux 

Athena 

Forte 
Plaza 

Deco 

Kompact 

 
 

98 Niven Street 

PO Box 3231 

Onekawa 

Napier 

Phone: 06 8438260 

Fax: 06 8430505 

Email: 

hothouse@firenzo.co.nz

 

Website:  