background image

OWNERS 

MANUAL

 

economical. safe. simple

TABLE OF CONTENTS

If you need Help   

 

p 2

Features and Benefi ts 

 

p 2

Important Instructions 

 

p 2

What’s in the box  

 

p 3

Wall Mounting Instructions 

p 3

Locking Bar Feature 

 

p 4

Hardwiring Instructions   

p 4

Operating Instructions 

 

p 6

How the Envi Works 

 

p 6

Unique Safety Features   

p 6

Grounding 

  p 

6

Optimal Operating Conditions 

p 6

Maintenance 

  p 

7

Storage 

   p 

7

Troubleshooting 

  p 

7

Specifi cations & Certifi cations 

p 7

Warranty   p 

8

MODELS COVERED BY THIS MANUAL

475 Watt - 120 Volt Models: 

HH1012T  

(Plug-In with Thermostat)

HH1012N  

(Plug-In No Thermostat)

HW1012T  

(Hardwired with Thermostat)

HW1012N  

(Hardwired No Thermostat)

475 Watt - 220 Volt Models: 

HH1022T  

(Plug-In with Thermostat)

HH1022N  

(Plug-In No Thermostat)

HW1022T  

(Hardwired with Thermostat)

HW1022N  

(Hardwired No Thermostat)

475 Watt - 230 Volt Models: 

HH1023T  

(Plug-In with Thermostat)

HH1023N  

(Plug-In No Thermostat)

HW1023T  

(Hardwired with Thermostat)

HW1023N  

(Hardwired No Thermostat)

DCN-630013-110513

wall-mounted room heater

United States Patent:  8,477,176

 


background image

Page 2

economical. safe. simple.

IMPORTANT INSTRUCTIONS

SAVE THESE INSTRUCTIONS

• 

Eliminates hot and cold spots where central heat is  
ineffective.

• 

Ultra Safe - cool to the touch (90

o

F/32

o

C) can leave on 

unattended 24/7.

• 

Healthy - won’t blow dust and allergens around or dry 
out the air.

• 

Totally silent fanless teachnology.

• 

Auto-dimming of power light for dark bedrooms.

• 

Easy Installation – no drill required for mounting to wall.

• 

Slim - space saving design, only 2in (5cm) thin.

• 

Long life - No moving parts, crack resistance surface

• 

Now available in hardwired & USA 220volt models.

FEATURES & BENEFITS 

• 

American Owned & Built with 3 year Warranty (USA )

• 

ISO 9001 Quality Certification.

• 

Patented, efficient “Stack Convection”  Technology 

• 

Adjustable Temperature control with simple operation.

• 

Wall-Sens

TM

 Technology, safety cut off feature.

• 

NEW!  

Internal Safety Locking Feature, locks heater to 

wall using provided allen key tool.

• 

Convenient cordset storage inside the heater.

• 

Turn down the central heat thermostat and use envi 
heaters where needed.

• 

Environmentally friendly - low power consumption.  

THANK YOU FOR CHOOSING THE ENVI HEATER

Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects, instal-
lation and care of your new Envi Heater.  For your own records, please attach a copy of your sales receipt to this manual.  Also, 
write the store name/location, date, and serial number in the warranty section on the back of this manual (page 8).

MISSING PARTS? HAVE QUESTIONS OR NEED HELP?  

(PLEASE DO NOT RETURN TO RETAIL STORE BEFORE YOU CALL THE ENVI HELP DESK)
We are here to help you with any questions you might have.  Before you call for help though, please read this manual as it 
contains instructions to help you to install, operate and maintain your heater properly.  If you receive a damaged heater - please 
immediately contact the dealer that sold you your Envi heater.  If you still need help please call the Envi Help desk in the  
USA/Canada Toll Free @ (800) 807-0107 or if calling from outside the USA call  +1 (281) 516-1577. 

HEATER WILL NOT OPERATE UNLESS MOUNTED

When using electrical appliances, basic precautions should 
always be followed to reduce the risk of fire, electric shock, and 
injury to persons, including the following:
1.  Read all instructions before installing or using this heater.
2.  Extreme caution is necessary when any heater is used by or 

near children or invalids, or when the heater is left operat-
ing and unattended.

3.  Do not operate any heater after it malfunctions. Discon-

nect power at service panel and have heater inspected by 
a reputable electrician before reusing.

4.  For plug-in heaters, to disconnect, push power button to 

turn heater OFF (the power indicator light will turn off), 
then remove plug from outlet. Pull firmly on the plug, do 
not unplug by pulling on the cord.

5.  Connect to properly grounded outlets only.
6.  For hardwired heaters, to disconnect, turn controls to off, 

and turn off power to heater circuit at main disconnect 
panel (or operate internal disconnect switch if provided).

7.  Do not insert or allow foreign objects to enter any ventila-

tion or exhaust opening as this may cause an electric shock 
or fire, or damage the heater.

8.  To prevent a possible fire, do not block air intakes or ex-

haust in any manner.

9.  A heater has hot or arcing parts inside. Do not use in areas 

where gasoline, paint, explosive and/or flammable liquids 
are used or stored. Keep unit away from heated surfaces 
and open flames.

10.  Use this heater only as described in this manual. Any other 

use not recommended by the manufacturer may cause fire, 
electric shock, or injury to persons

11.  Use only for the intended household or office uses as de-

scribed in this manual. Any other use not recommended by 
the manufacturer may cause fire, electric shock, or injury to 
persons. The use of non-recommended attachments sold 
by unauthorized dealers may cause hazards.

12.  Do not use outdoors.
13.  This heater is intended for use as a WALL MOUNTED heater 

only. Failure to properly secure the heater to a flat, level 
and vertical wall may result in heater malfunction and/or 
property damage.

14.  This heater will not operate (power is disconnected) unless 

it is attached to a wall using the supplied wall mounting 
clips which engage the internal “wall-sens” safety switch.

15.  DO NOT attempt to repair or replace any electrical or 

mechanical functions on this unit. Doing so will void your 
warranty. The inside of the unit contains no user service-
able parts. Qualified personnel should perform all servicing 
only.

 


background image

Page 3

economical. safe. simple.

Remove the heater, mounting kit, and packaging insert frame 
from the box. Keep the packaging materials for future use.

1.  Unwrap and fl atten the sides of the packaging insert 

frame (mounting template) and stand the template on 
the fl oor.  The sides of the template have pre-punched 
holes to mark the heater mounting height for either 6” or 
or 8” (15 or 20cm) from the bottom of the heater to the 
fl oor.  Choose either mounting height, and mark three 
hole locations on the wall. (see Fig. 1). The top two hole 
locations are for the mounting clips and the bottom 
location is for a third mounting screw hidden inside the 
bottom access door as described in step 5 below.

 

NOTE: Most installers use the internal locking bar screw 
instead of the bottom mounting hole.

2.  Screw the anchors into wall at the marked locations . 

(Fig. 2).  

The distance from the top screws to the fl oor 

should be approx. 18” to 20” (45cm to 50cm). 

If a stud is in the way, do not use the drywall anchor 

supplied, just screw directly into the stud.  The anchor 
shown in the illustration is for drywall installation. For 
masonry walls, use the masonry wall anchors provided 
and drill a 4.5mm (3/16inch) hole using a masonry drill 
bit (not supplied).

3.  Screw the two mounting clips (with arrow pointing 

upward) into the top two anchor locations and secure 
fi rmly to the wall anchors using the provided screws. 
(see Fig. 3). DO NOT overtighten. There should be a gap 
behind the mounting clip to hang the heater on.

4.  If you plan on using bottom screw, remove the bottom 

access door before you mount the heater. 

WHAT IS IN THE BOX

• 

475 Watt Envi Wall Mounted Heater

• 

Owners Manual

• 

2 x Mounting Clips

• 

3 x #8 Mounting Screws

• 

3 x Drywall Anchors / 3 x Masonry Anchors

• 

Locking Bar Screw and Allen Key tool

• 

Knockout Hole Grommet (hardwired models only) 

• 

Wall Anchor Marking Template. Template holes are 
marked on the outer edge of the packaging insert frame. 

INSTALLATION INSTRUCTIONS

WALL MOUNTING

Fig. 3

Fig. 2

Fig. 1

IMPORTANT MOUNTING TIPS

 

1)   Only use the bottom mounting screw if you do not 
intend to use the internal locking bar/screw mechanism.
2)   The bottom mounting screw can be marked by hang-
ing the heater fi rst, then using the heater as a template. 
3)   The right hand side of the heater must be securely and 
fi rmly pushed down on the clip to engage the “wall-sens” 
power cut-off  switch inside the heater. Align this side 
of the heater fi rst, to ensure the switch is activated. For 
uneven walls, a thin washer can be used to widen the gap 
behind this clip to help seat the heater properly.

17 3/4”

(451mm)

Mounting Clip
Hole Location-
Choose 6” or 8” 
Height (15 or 20cm)

OPTIONAL WHEN 
INTERNAL LOCK-
ING BAR USED!

Bottom Mounting
Hole Location
Choose 6” or 8” 
Height (15 or 20cm)

Fig. 5

 


background image

Page 4

economical. safe. simple.

HARDWIRING INSTRUCTIONS

The Envi Heater is available in some regions as a hardwired model: HW1012T / HW1022T / HW1023T (with built in thermostat)  
and  HW1012N / HW1022N / HW1023N (with no built in thermostat, instead a cover plate is in its place)

The Envi Heater can be hardwired direct to a mains supply, branch circuit or it can be hardwired to a line voltage external ther-
mostat of the same voltage as the heater (eg. 120v) or to an external switch or timer.  Consult the instructions for each of these 
control devices for specifi c wiring instructions.  The Envi Heater can also be wired as multiple heaters on the same circuit or 
controller.  For these Multi-Heater Hardwiring instructions please consult the installation page of the website www.eheat.com.  
The Envi Heater can also be hardwired to a 24volt thermostat using a 24v relay.  Please consult a certifi ed electrician and ensure 
that all electrical work is done in accordance with applicable electrical and building codes. 

CAUTION

: To prevent short circuits and electrical shocks turn the power off  at the main electrical panel before attempting the 

hardwiring installation or any repairs.  If the internal power cable (cordset) is damaged it must be replaced by the manufacturer.  

NOTE: 

This hardwired heater must be connected to the correct voltage circuit according to its model designation, ie.

(HW1012 = 120volts, HW1022 = 220volts and HW1023 = 230volts).  Disconnect the power supply before making wiring connec-
tions to prevent electrical shock and equipment damage.  

WIRING SCHEMATIC

NOTE:  The following wiring schematic is for a single Envi Heater installation to the applicable ac mains supply circuit and as-
sumes that the there are no external controls being wired into the unit.  For wiring of external controls (thermostat/switches or 
timers) please consult the website www.eheat.com for examples of external control wiring instructions.  

5.  Install heater on mounting clips (align right side fi rst) and  

make sure to press down fi rmly on the heater to ensure a 
secure fi t. You will hear it “snap” into place. (Fig. 5 above)

6.  (OPTIONAL) Install the third screw inside the bottom access 

door area (Fig. 6).  Replace the door.   Please note: for clarity 
the cordset is not shown exiting the heater.

For additional information visit www.eheat.com

MOUNTING INSTRUCTIONS (CONT)

Fig. 6

NEW LOCKING BAR FOR PERMANENT ATTACHMENT 

Fig. 7

The Envi Wall-Mounted Heater models now come with an additional 
method to permanently attach the heater to the wall.  A locking bar 
mechanism is built inside the heater, which is engaged by screwing an 
external locking screw into the bottom of the heater vent.  The lock-
ing screw and Hex/Allen Key are both provided in the mounting kit. 
This locking bar method is an alternate method to the existing bottom 
screw installation procedure above, however many customers will fi nd 
that the locking bar attachment method is suffi  cient by itself.

STEP 1 - Installing the Locking Bar Screw (Fig. 7) 

BEFORE YOU 

MOUNT THE HEATER TO THE WALL.  Take the locking bar screw out of 
the mounting kit and while the heater is laying fl at, use the Hex/Allen 
key provided to get the screw started in the hole at the bottom left 
hand side of the envi heater (Fig 1).  Screw the locking screw in about 
3/8 of an inch (Fig 2) but make sure you do not screw it in too far as it 
will obstruct the mounting holes at the back of the heater and prevent 
mounting on the wall.

STEP 2 – Mount the Heater.

 Attach the heater to the wall by following the rest of the mounting instructions shown above.

STEP 3 – Tighten Locking Screw 

(Fig 7) Follow the rest of the mounting instructions to ensure the heater is properly seated on 

the mounting clips and then tighten the locking screw to fi x the heater to the wall. DO NOT USE A POWER TOOL!!! 
DO NOT OVERTIGHTEN, just turn the screw until the locking bar presses gently up against the left hand mounting clip inside the 
heater. 

 Congratulations, you have now permanently mounted your Envi Heater !

Gently

 tighten Locking 

Screw using supplied 
Allen-key tool

 


background image

Page 5

economical. safe. simple.

STEP 1

Determine the best wall mounting location of the Envi Heater in a room.   If the proper electrical wiring and wall box already 
exists at a suitable height on the wall, then choose a suitable knock-out hole on the back of the heater (4 holes to choose from) 
and position the heater on the wall so that the knockout hole lines up with the electrical wall box.  

If new electrical wiring and a wall box is to be installed, then it is 
best to mount the heater fi rst and then determine the correspond-
ing location on the wall for the new electrical wiring wall box.  When 
installing a new wall box, ensure it is at a proper location on the wall 
to allow the heater to remain at 6” to 8” (15 to 20cm) or so above the 
fi nished fl oor level.  

Turn the power OFF at the main electrical panel to the heater circuit.  
Run the electrical wiring and secure it properly to the electrical box 
per applicable electrical and building codes.  (NOTE:  Although the 
Envi Heater has a low amperage draw (eg. 4amps@120v), the electri-
cal code requires a minimum supply wire gauge to be used, so make 
sure you check fi rst.)

STEP 2

Mount the Envi Heater using the two mounting clips per the “Wall 
Mounting Instructions” (see page 2) contained herein to ensure that 
the heater is at the proper location on the wall and that the knockout hole is aligned with the supply wiring.

STEP 3

Remove the Envi heater from the wall to continue with the hardwiring steps. If not already done at Step 1, remove a knock out 
hole (a screw driver can be used), on the back of the heater, and install the supplied protection grommet into the knockout 
hole.  The bottom access door is already removed and supplied in the mounting kit. Pull the supply wiring into the Envi Heater 
and out through the bottom access opening. Then pull the Envi cordset wiring through bottom access opening, and using wire 
nuts (not supplied) connect the heater wires L1 (live) , L2 (neutral) and G (ground) to the corresponding supply wires per the 
wiring schematic above.  Push the connected wiring/nuts inside the opening and re-attach the bottom access door. 

NOTE:   ENSURE YOU ONLY CONNECT 120VOLT SUPPLY VOLTAGE TO 120VOLT ENVI HEATERS. IF YOU ARE NOT SURE IF YOU HAVE 120VOLT 
OR 220/240VOLT SUPPLY AVAILABLE  - YOU SHOULD NOT BE PERFORMING THIS INSTALLATION!  PLEASE HIRE A QUALIFIED ELECTRICIAN.

STEP 4

Re-mount the Envi Heater to the wall, ensuring all three mounting screws are used.  Ensure that any wiring is pushed inside the 
wall electrical box and is not trapped between the Envi Heater and the wall.

STEP 5

Turn the power ON at the main electrical panel to the heater circuit.  Check that there are no obvious problems with the hard-
wiring to the heater (such as crackling noises, sparks or smoke) and if everything is okay, turn on the power to the heater by 
pressing the on/off  button.  If the wiring has been performed correctly, then the power indicator light will glow red.

HARDWIRING INSTRUCTIONS (CONT.)

Knock-out Holes 
1.5in (3.8cm) apart
(Twist to remove)

Hardwired
Cordset

Bottom Screw 
(Optional - see notes)

G

GROUND
WIRE

SUPPLY
VOLTAGE
(see note above)

L1

L2

s

Envi Heater
Hardwired 
Models Only

Envi Heater Hardwired Cordset

Wire Color Guide

L1 = Black Wire (Live)

G = Green Wire (Ground)

L2 = White Wire (Live)

 


background image

Page 6

economical. safe. simple.

HOW IT WORKS

The Envi Heater is designed with innovative “Stack Convection Technology” that eff ectively heats a room with minimal energy.  
The Envi’s inner chamber simulates “stacks” of varying height, which boost airfl ow through the heater to achieve maximum 
effi  ciency. The end result is enhanced airfl ow at safe air temperature, all without the use of a fan. The Envi heater will provide 
consistent, comfortable, silent heat without drying out the air or leaving cold spots in the room.

OVERHEAT SAFETY FEATURE

This heater is equipped with an overheat safety feature. When the heaters internal components reach a certain temperature 
that could cause overheating and a possible fi re, the heater will automatically shut off . To reset the heater, unplug the heater 
power cord from the electrical outlet for 10 minutes. After 10 minutes, plug the heater into the electrical outlet and turn on us-
ing the heater’s on/off  switch located on the front of the unit.

WALL-SENS

TM

 SAFETY FEATURE

In addition to the overheat safety cut-off , the Envi Heater is now equipped with an additional layer of safety to give you greater 
peace of mind.  Wall-Sens

TM

 technology means that in the event that the Envi heater is ever removed from the wall, power will 

be immediately cut to the heater.  This of course means that the heater will not work if it is simply removed from its packaging 
and plugged into a wall outlet.  It must be mounted properly (safely) and then plugged in (or hardwired) in order for it to be 
begin to heat.  

GROUNDING

Plug-in models of the envi heater are for use on standard electrical circuits (eg. 120v for USA/Canada). The cord has a three-
blade grounding plug. An adapter can be obtained at most hardware or electrical stores for connecting three-blade grounding 
type plugs to two-slot receptacles. The grounding lug extending from the adapter must be connected to a permanent ground 
such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.  

DO NOT DEFEAT THE SAFETY PURPOSE OF THE GROUNDED PLUG.

OPERATING INSTRUCTIONS

1.  Install the heater on a fi rm, level wall and plug the power cord 

into a grounded power outlet (or hardwire it if applicable). The 
heater will only operate when it is properly attached to the 
mounting clips. Be sure to mount in upright position with the 
thermostat knob on the top of the heater.

2.  Once the heater is connected, press the front on/off  power 

switch and the POWER INDICATION LIGHT will glow red. (Fig. 5)

3.  The Envi Heater is equipped with a built-in thermostat which is 

adjusted with a dial at the top of the heater.  Adjust the room 
temperature by turning the THERMOSTAT DIAL clockwise to 
increase the room temperature. If the area becomes too warm, 
rotate the THERMOSTAT DIAL counter-clockwise until you reach a point where the temperature is more comfortable. (Fig. 5)

4.  Once you have chosen the desired setting, the thermostat will maintain a constant temperature.  NOTE:  Models with no 

thermostat have no temperature control and will stay on until the heater is powered off .

5.  The heater is equipped with an innovative auto dimming feature that dims the power indication light for light sleeper in 

darkened bedrooms. The heater automatically 
detects when the light level in a room drops and then dims the power light.

6.  The plug-in cordset of the Envi heater can be stored inside the bottom access door.  Determine how much cordset you 

require to extend out of the heater.  Remove the heater from the wall, and remove the bottom access door.  Carefully push 
the excess cordset inside the heater and replace the bottom access door.  Re-install the heater to the wall and plug-in the 
cordset to continue using your heater.  For more information please visit the installation web page of www.eheat.com

OPTIMAL OPERATING CONDITIONS

To get the most out of your Envi Heater, please follow these helpful hints:

1.  VERY IMPORTANT!!! For optimal performance in a room, close all windows and doors and for fi rst time use, leave on 

for 48 - 72 hrs. 

This will allow the room to reach equilibrium temperature while the heat is gradually building up. 

2.  For optimal performance, mount the heater on an interior wall with the bottom of the heater 6” to 8” (15 to 20cm) from the 

fl oor. For smaller rooms this can be increased with little detriment, however try to keep the bottom of the heater a maxi-
mum of 18” (46cm) from the fl oor.

3.  The 475 Watt Envi heater is designed to heat rooms 130 to 150 ft

2

 feet in size (12m

2

 to14m

2

).  This equates to a 10ft x 14ft 

room size (3 x 4meters). Of course, this will vary depending on a number of factor, including outdoor temperature, room 

OPERATING INSTRUCTIONS

 


background image

Page 7

economical. safe. simple.

CARE & MAINTENANCE INSTRUCTIONS

OPERATING INSTRUCTIONS (CONT.)

TROUBLE SHOOTING

SPECIFICATIONS & CERTIFICATIONS

CLEANING

1.  Unplug the unit and let it cool completely.
2.  To remove dust from the Envi heater, use a soft cloth.
3.  To remove marks or stains from the heater, the front outer shell can be cleaned with a soft, damp cloth.  You may use a 

mild detergent if necessary.  After cleaning, dry the unit with a soft cloth.  CAUTION: Do not let liquid enter the heater.

4.  Do not use alcohol, acetone based cleaners, gasoline, abrasive powders, furniture polish, or abrasive or rough cloths or 

brushes to clean the front of the heater. This may cause damage or deterioration to the surface.

5.  Do not immerse the heater in water.
6.  Wait until the unit is completely dry before using again.

STORAGE

Store the heater in a cool, dry location when not in use.  However, the Envi Heater is a slim, attractive wall mounted heater 
than can be left mounted on the wall year round. 

If the heater will not operate, please check the following before seeking repair or service:

1.  Check that the heater is correctly installed against the wall using the supplied mounting clips.  The Envi Heater 

WILL NOT 

OPERATE AT ALL

 unless it is mounted on a wall due to the inclusion new “Wall-Sens

TM

 Technology” safety feature!

2.  Check if the heater is set to ON by confi rming the light on the front of the panel is lit.  If not, press the on/off  power 

switch.

3.  Check if the power cord is plugged into an electrical outlet, if not, plug it in.
4.  If the heater has been hardwired, consult an electrician to check that all connections have been made correctly.
5.  Check if electricity to the circuit is working. This can be found in your breaker box, check to make sure the breaker is in the 

“on” position.

PRODUCT SPECIFICATIONS  

 

 

 

            SAFETY LISTINGS

COMMERCIAL FIRE SAFETY  COMPLIANCE & CALIFORNIA TITLE 24 CERTIFICATION

insulation, room draftiness, room objects, etc.

4.  To save energy and to reduce your heating bills, place the heater in a room or area that needs extra heat instead of rais-

ing the thermostat on your central heating system. This heater will function very well as both a sole source of heat or as an 
additional heating source that can easily maintain the temperature in most rooms and attached bathrooms if the correct 
number of Envi heaters are installed. There is no need to increase the heat in the entire house when you only need comfort 
in the room in which you are currently located.

5.  We highly recommend that our customers weatherize their home to further reduce their heating bills. Simple tasks such as 

replacing weather stripping around doors and windows, caulking door and window seams, sealing attics and basements 
properly, and adding more insulation to your walls and ceiling will help further to reduce home heating costs. 

Conforms to UL Std: 

UL 2021

Cert. to CAN/CSA Std: 

C22.2 No. 46-M1988

Conforms to IEC Std: 

60335-1 & 60335-2-30

Conforms to AS/NZS: 

60335.1 & 60335.2.30

Power Rating: 

 

475 Watts (All Models)

Volt & Amp Rating: 

HH/HW1012 Models = 

3.95 Amps@120volts

   

HH/HW1022 Models = 

2.16 Amps@220volts

   

HH/HW1023 Models = 

2.06 Amps@230volts

 

Unit Size: 

 

19.3in W x 2.2in D x 22.2in H   

 

 

 

(49.0cm W x 5.6cm D x 56.4cm H)

Net Weight: 

 

10 lbs (4.5 kg)

Packaged Wt: 

 

12 lbs (5.5 kg)

The Envi Heater is in compliance with the requirements of The Life Safety Code, NFPA 101 (2012), section 19.7.8.  The Envi 
heater is a fi xed wall heater (not portable) and operates with low surface temperatures and is thus suitable for commercial use 
in Elderly Care, Childcare, corporate and government facilities. The envi heater is also compliant for California Title 24 use in 
Residential New Construction, Alterations and Additions. Contact the manufacturer for a copy of the certifi cation.

 


background image

Page 8

economical. safe. simple.

WARRANTY

Three Year Limited Warranty 

1.  The manufacturer warrants the accompanying Envi Heater to be free of defects in material and workmanship for the ap-

plications specified in its operation instructions for a period of THREE (3) years from the date of original purchase in the 
United States of America.  If the unit exhibits a defect in normal use, the manufacturer will, at its option, either repair or 
replace it, free of charge within a reasonable time after the unit is returned during the warranty period.  

2.  As a condition to any warranty service obligation, the consumer must present a copy of the original purchase invoice. 

3.  THESE WARRANTIES DO NOT APPLY FOR:

• 

Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in material 
or workmanship.

• 

Damage caused by improper installation or connection to incorrect supply voltage.  

• 

Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions in the 
instructions.

• 

Damage to the finish of the case, or other appearance parts caused by wear.

• 

Damage caused by repairs or alterations of the unit by anyone other than those authorized by the Manufacturer.

• 

Freight and Insurance cost for the warranty service. 

4.  ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO A THREE-YEAR DURA-

TION OF THIS EXPRESS LIMITED WARRANTY.  THE MANUFACTURER DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR 
INCIDENTAL DAMAGES AND IN NO EVENT SHALL THE MANUFACTURERS LIABILITY EXCEED THE RETAIL VALUE OF THE 
UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT. 

5.  Note: This warranty does not renew or extend with a replacement product. All warranties are from the date of the original 

product purchase. 

6.  This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-

vaged, or refurbished products. 

7.  As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow limitation 

on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you specific legal 
rights, and you may also have other rights that vary from state to state. 
 

 

Manufacturer’s Contact Information

:

eheat, Inc. / Conservetec International  

Tomball, TX, United States of America

Email: cs@eheat.com   

Phone:  +1 (281) 516-1577 

Web:  www.eheat.com or  www.envi-heat.com

 

Registration Details

 

Store Name: 

Location: 

Date Purchased:  

Serial Number: 

(Serial # is found on back of unit)