QUICK SETUP GUIDE

R O T A R Y


background image

2

Updated for V2 Operators

Updated for V2 Operators

WARNING

Always ensure that all safety instructions as described in the 

Installation Manual are adhered to during the installation 

process, and also apply to the completed installation.

TIP!!  If in doubt .... refer to the installation manual.  (IM)

This guide is intended for the experienced installer who 
has done an R3 or R5 installation before, knows all the 
safety  aspects  required  of  a  site,  but  who  needs 
reminding of the basic steps to follow. 

Check that you have all the tools required.  (

IM

 page 12)

Consider all cabling requirements and routing as in Figure 9. (
14

IM

 page 

)

2

1

3

4

R

EQUIRED

 T

OOLS

 & E

QUIPMENT

C

ABLING

 R

EQUIREMENTS

O

PERATOR

 I

NSTALLATION

S

ITE

 C

ONSIDERATIONS

3

Figure 1 Gate Opening Angle Diagram

o

110

o

120

o

100

o

90

o

80

o

70

o

60

(Gate opening angle)

o

0

b

Check for the safety and suitability of the site by looking at:  (

IM

 page 

13)

All safety and local authority requirements.
That the gate is within the operator specifications.
Check that there is enough ground clearance to enable assembly of 
the drivearm clamps. (See Figure 4)

!
!
!

!
!

Estimate the gate swing angle with figure 1.
Then mark the operator’s position according to figure 2 or 3. 

(IM 

page 15

)


background image

2

Updated for V2 Operators

Updated for V2 Operators

WARNING

Always ensure that all safety instructions as described in the 

Installation Manual are adhered to during the installation 

process, and also apply to the completed installation.

TIP!!  If in doubt .... refer to the installation manual.  (IM)

This guide is intended for the experienced installer who 
has done an R3 or R5 installation before, knows all the 
safety  aspects  required  of  a  site,  but  who  needs 
reminding of the basic steps to follow. 

Check that you have all the tools required.  (

IM

 page 12)

Consider all cabling requirements and routing as in Figure 9. (
14

IM

 page 

)

2

1

3

4

R

EQUIRED

 T

OOLS

 & E

QUIPMENT

C

ABLING

 R

EQUIREMENTS

O

PERATOR

 I

NSTALLATION

S

ITE

 C

ONSIDERATIONS

3

Figure 1 Gate Opening Angle Diagram

o

110

o

120

o

100

o

90

o

80

o

70

o

60

(Gate opening angle)

o

0

b

Check for the safety and suitability of the site by looking at:  (

IM

 page 

13)

All safety and local authority requirements.
That the gate is within the operator specifications.
Check that there is enough ground clearance to enable assembly of 
the drivearm clamps. (See Figure 4)

!
!
!

!
!

Estimate the gate swing angle with figure 1.
Then mark the operator’s position according to figure 2 or 3. 

(IM 

page 15

)


background image

100

79

158

110

!

specifications (IM page 9)

!

Only recommended values are provided. For 
variances, refer to the Installation Manual.

!

All dimensions shown are indicated in millimetres.

!

All recommended values will result in gates with 
similar opening times.

Ensure that the gate does not exceed the relevant 

Pedestal Mount

Installation

b

Gate Bracket

C

B

H

Gate Opening

Angle (Degrees)

60

700

0

90

130
220
355
570
605

750
750
750
700
700
600
450

70

700

80

700

90

700

100

650

110
120

610
570

Figure 2 Standard Pedestal Mount Installation

S

TANDARD

 P

EDESTAL

 M

OUNT

B E   S U R E   T O   U S E   A   L O N G  
C O N N E C T I N G   A R M   F O R   T H I S  
INSTALLATION TYPE.

Gate Bracket 

C

H

GATE LEAF IN CLOSED POSITION

b

B

Drive 

Arm 

D

see Fig. 6

158

Pedestal

#

50mm

GA

TE LEAF IN OPEN POSITION

4

5

Wall Mount 
Installation

!

!

Only recommended values are provided. For variances, refer to the Installation Manual.

!

All dimensions shown are indicated in millimetres.

!

All recommended values will result in gates with similar opening times.

Ensure that the gate does not exceed the relevant specifications (IM page 9)

Figure 3 Standard Wall Mount Installation

P

ERPENDICULAR

 W

ALL

 M

OUNT

 

BE  SURE  TO  USE  A  SHORT  CONNECTING  ARM  FOR 
THIS INSTALLATION TYPE.

H

B

Drive 

Arm 

D

 see Fig. 6

b

Gate Opening

Angle (Degrees)

B

H

210
305
380
485

140
180

80
80

90

100
110
120

60
70
80

140
180
180

180
180
140

GATE LEAF IN CLOSED POSITION

b

Gate Bracket 

C

100

272

110

Gate Bracket

C

700
700
610

700

700

700

700


background image

100

79

158

110

!

specifications (IM page 9)

!

Only recommended values are provided. For 
variances, refer to the Installation Manual.

!

All dimensions shown are indicated in millimetres.

!

All recommended values will result in gates with 
similar opening times.

Ensure that the gate does not exceed the relevant 

Pedestal Mount

Installation

b

Gate Bracket

C

B

H

Gate Opening

Angle (Degrees)

60

700

0

90

130
220
355
570
605

750
750
750
700
700
600
450

70

700

80

700

90

700

100

650

110
120

610
570

Figure 2 Standard Pedestal Mount Installation

S

TANDARD

 P

EDESTAL

 M

OUNT

B E   S U R E   T O   U S E   A   L O N G  
C O N N E C T I N G   A R M   F O R   T H I S  
INSTALLATION TYPE.

Gate Bracket 

C

H

GATE LEAF IN CLOSED POSITION

b

B

Drive 

Arm 

D

see Fig. 6

158

Pedestal

#

50mm

GA

TE LEAF IN OPEN POSITION

4

5

Wall Mount 
Installation

!

!

Only recommended values are provided. For variances, refer to the Installation Manual.

!

All dimensions shown are indicated in millimetres.

!

All recommended values will result in gates with similar opening times.

Ensure that the gate does not exceed the relevant specifications (IM page 9)

Figure 3 Standard Wall Mount Installation

P

ERPENDICULAR

 W

ALL

 M

OUNT

 

BE  SURE  TO  USE  A  SHORT  CONNECTING  ARM  FOR 
THIS INSTALLATION TYPE.

H

B

Drive 

Arm 

D

 see Fig. 6

b

Gate Opening

Angle (Degrees)

B

H

210
305
380
485

140
180

80
80

90

100
110
120

60
70
80

140
180
180

180
180
140

GATE LEAF IN CLOSED POSITION

b

Gate Bracket 

C

100

272

110

Gate Bracket

C

700
700
610

700

700

700

700


background image

6

7

Figure 5 Wall/Gate Position

6

R

OUTE

 C

ABLES

 & S

ECURE

 M

OTOR

!

!
!

Route cables as determined in the cabling plan in Figure 9.
Make sure at least 400mm of cable protrudes above the pedestal or wall 
mount bracket.

  (IM 

page 22

)

W

ALL

 M

OUNT

 I

NSTALLATION

C (See Fig. 3)

Wall 

Bracket

Gate Bracket

85

Minimum 125mm to allow for

drive arm clamp assembly

3

7

m

m

5

M

OUNT

 

THE

 G

ATE

 

BRACKET

 

AND

 

D

ETERMINE

 P

EDESTAL

 H

EIGHT

 

Figure 4 Pedestal/Gate Bracket vertical position

P

EDESTAL

 M

OUNT

 I

NSTALLATION

!

!

!

Locate a suitable place for mounting the gate bracket according to dimen-
sion “C” in the tables of Figures 2 or 3.
Determine pedestal or wall mount bracket height relative to gate bracket 
as in figure 4 and 5.  

(IM page 21)

Mount the gate bracket.

300mm sqr

500mm

Minimum 125mm to allow for

drive arm clamp assembly

Concrete

Pedestal

Cabling

C (See Fig. 2)

37mm

85mm

Gate

Bracket


background image

6

7

Figure 5 Wall/Gate Position

6

R

OUTE

 C

ABLES

 & S

ECURE

 M

OTOR

!

!
!

Route cables as determined in the cabling plan in Figure 9.
Make sure at least 400mm of cable protrudes above the pedestal or wall 
mount bracket.

  (IM 

page 22

)

W

ALL

 M

OUNT

 I

NSTALLATION

C (See Fig. 3)

Wall 

Bracket

Gate Bracket

85

Minimum 125mm to allow for

drive arm clamp assembly

3

7

m

m

5

M

OUNT

 

THE

 G

ATE

 

BRACKET

 

AND

 

D

ETERMINE

 P

EDESTAL

 H

EIGHT

 

Figure 4 Pedestal/Gate Bracket vertical position

P

EDESTAL

 M

OUNT

 I

NSTALLATION

!

!

!

Locate a suitable place for mounting the gate bracket according to dimen-
sion “C” in the tables of Figures 2 or 3.
Determine pedestal or wall mount bracket height relative to gate bracket 
as in figure 4 and 5.  

(IM page 21)

Mount the gate bracket.

300mm sqr

500mm

Minimum 125mm to allow for

drive arm clamp assembly

Concrete

Pedestal

Cabling

C (See Fig. 2)

37mm

85mm

Gate

Bracket


background image

8

9

8

C

UT

 D

RIVE

 A

RM

 

TO

 L

ENGTH

Figure 6 Cut Drive Arm Length

C

UT

 D

RIVEARM

 

TO

 L

ENGTH

7

F

ASTEN

 G

EARBOX

 

IN

 P

OSITION

!
!

Fasten the motor onto the pedestal adaptor plate or the wall bracket using 
the M8 bolts and washers supplied.  

(IM

 page 23

)

!

!
!

Using the relevant tables below, read off the required drive arm length.
Then cut the drivearm 50mm longer than D, as shown in Figure 6.

Connecting Arm

Cut drivearm length=D+50mm 

Drivearm

Drivearm (D) + 50

Drivearm (D)

b

Standard 

Pedestal Mount 

Drivearm

Perpendicular

Wall Mount

Drivearm

D

D

Gate Opening

Angle (Degrees)

60

325

430

370

470
490
480
470

70
80
90

100
110
120

480
500
500

250
300
350
420

!

!
!

Put the gearbox into manual mode.  

(IM

 page 24

).

Fit the drive arm to the operator as shown.

9

F

IT

 

THE

 D

RIVE

 A

RM

A

SSEMBLE

 C

LAMP

 

TO

 D

RIVE

 A

RM

Figure 7 Assemble Clamp to Drive Arm

To  mount:  push  clamp  onto  drive  shaft,
tap into place, slide drive arm into clamp,
slip  wedge  in  and  fasten  with  bolt  and 
washer.  

R3

R5

 Clamp

Drive Arm

M12 x 65 Bolt

M12 Washer

Wedge

 Clamp

Drive Arm

M12 x 65 Bolt

M12 Washer

Wedge


background image

8

9

8

C

UT

 D

RIVE

 A

RM

 

TO

 L

ENGTH

Figure 6 Cut Drive Arm Length

C

UT

 D

RIVEARM

 

TO

 L

ENGTH

7

F

ASTEN

 G

EARBOX

 

IN

 P

OSITION

!
!

Fasten the motor onto the pedestal adaptor plate or the wall bracket using 
the M8 bolts and washers supplied.  

(IM

 page 23

)

!

!
!

Using the relevant tables below, read off the required drive arm length.
Then cut the drivearm 50mm longer than D, as shown in Figure 6.

Connecting Arm

Cut drivearm length=D+50mm 

Drivearm

Drivearm (D) + 50

Drivearm (D)

b

Standard 

Pedestal Mount 

Drivearm

Perpendicular

Wall Mount

Drivearm

D

D

Gate Opening

Angle (Degrees)

60

325

430

370

470
490
480
470

70
80
90

100
110
120

480
500
500

250
300
350
420

!

!
!

Put the gearbox into manual mode.  

(IM

 page 24

).

Fit the drive arm to the operator as shown.

9

F

IT

 

THE

 D

RIVE

 A

RM

A

SSEMBLE

 C

LAMP

 

TO

 D

RIVE

 A

RM

Figure 7 Assemble Clamp to Drive Arm

To  mount:  push  clamp  onto  drive  shaft,
tap into place, slide drive arm into clamp,
slip  wedge  in  and  fasten  with  bolt  and 
washer.  

R3

R5

 Clamp

Drive Arm

M12 x 65 Bolt

M12 Washer

Wedge

 Clamp

Drive Arm

M12 x 65 Bolt

M12 Washer

Wedge


background image

WARNING

1. Always check that the circuit breaker in the electrical panel is in the 

OFF position, and that all high voltage circuits (more than 42.4V) are 
completely isolated from the mains supply before doing any work.

2. Ensure that all low voltage systems (Less than 42.4V) are suitably 

protected from damage, by disconnecting all sources of power such 
as chargers and batteries before doing any work.

3. All electrical work must be carried out according to the requirements 

of  all  applicable  local  electrical  codes.(It  is  recommended  that  a 
licensed electrical contractor perform such work.) 

C

ONNECT

 

ALL

 W

IRING

1

!

!

Connect all cables as required to the control card and battery charger (See 
Figure 11 & 12).  (

IM

 page 48 & 49)

Check that the power source jumper is in the correct position.  (PSU or STD 
refer to 

IM

 page 27, Fig. 24)

Figure 9 Cabling Requirements

1

2

4

5

6

7

3

To dwelling

Isolator

Box

6

10

11

10

S

ET

 

THE

 C

ONNECTING

 A

RM

 L

ENGTH

!
!
!
!

!

!

!

!

Loosen the connecting arm slightly and move it to its fully retracted position.
Open the gate ½ way.
Assemble the connecting arm to the gate bracket.
Now slowly push the gate to its closed position. (The drive arm will turn, and 
the connecting arm will extend while doing so)
Check that the hinge points of the gate bracket, connecting arm and motor 
output shaft are in a straight line as shown in Figure 8.
Carefully  unhook  the  connecting  arm  from  the  gate  bracket  and  tighten 
lightly.
Check  the  gate  opens  and  closes  sufficiently  by  manually  operating  the 
gate.

!
!

Fully tighten connecting arm.
Apply the warning decals supplied to either side of the gate frame.

IF THE GATE OPENS TOO LITTLE

IF THE GATE OPENS TOO MUCH

Lengthen

 the drivearm by 10 mm and 

readjust the connecting arm.

Shorten

 the drivearm by 10 mm and 

readjust the connecting arm.

NB. Hinge points must be in a
straight line when gates are closed

GATE LEAF IN CLOSED POSITION

Figure 8 Align Gates

A

LIGNMENT

 

OF

 H

INGE

 P

OINTS

Electrical Set-Up

Electrical Set-Up


background image

WARNING

1. Always check that the circuit breaker in the electrical panel is in the 

OFF position, and that all high voltage circuits (more than 42.4V) are 
completely isolated from the mains supply before doing any work.

2. Ensure that all low voltage systems (Less than 42.4V) are suitably 

protected from damage, by disconnecting all sources of power such 
as chargers and batteries before doing any work.

3. All electrical work must be carried out according to the requirements 

of  all  applicable  local  electrical  codes.(It  is  recommended  that  a 
licensed electrical contractor perform such work.) 

C

ONNECT

 

ALL

 W

IRING

1

!

!

Connect all cables as required to the control card and battery charger (See 
Figure 11 & 12).  (

IM

 page 48 & 49)

Check that the power source jumper is in the correct position.  (PSU or STD 
refer to 

IM

 page 27, Fig. 24)

Figure 9 Cabling Requirements

1

2

4

5

6

7

3

To dwelling

Isolator

Box

6

10

11

10

S

ET

 

THE

 C

ONNECTING

 A

RM

 L

ENGTH

!
!
!
!

!

!

!

!

Loosen the connecting arm slightly and move it to its fully retracted position.
Open the gate ½ way.
Assemble the connecting arm to the gate bracket.
Now slowly push the gate to its closed position. (The drive arm will turn, and 
the connecting arm will extend while doing so)
Check that the hinge points of the gate bracket, connecting arm and motor 
output shaft are in a straight line as shown in Figure 8.
Carefully  unhook  the  connecting  arm  from  the  gate  bracket  and  tighten 
lightly.
Check  the  gate  opens  and  closes  sufficiently  by  manually  operating  the 
gate.

!
!

Fully tighten connecting arm.
Apply the warning decals supplied to either side of the gate frame.

IF THE GATE OPENS TOO LITTLE

IF THE GATE OPENS TOO MUCH

Lengthen

 the drivearm by 10 mm and 

readjust the connecting arm.

Shorten

 the drivearm by 10 mm and 

readjust the connecting arm.

NB. Hinge points must be in a
straight line when gates are closed

GATE LEAF IN CLOSED POSITION

Figure 8 Align Gates

A

LIGNMENT

 

OF

 H

INGE

 P

OINTS

Electrical Set-Up

Electrical Set-Up


background image

10

11

* Increase cable thickness if pillar lights are to be installed.
† Screened cable is always recommended to provide better protection against lightning - earth one end 

of screening.

CABLE REQUIREMENTS

1.

220V AC mains cable (3 core LNE 

4.

Radio receiver cable (3 core 0,5mm

2

0,5mm )*†, via mains isolator switch

multistranded).

Or

5.

Pedestrian key switch (if required) (2 

core 0,5mm multistranded).

Low voltage 16V AC battery charger 

2

supply (2 core 1,5mm )†.

6.

Infrared beams or safety edge (if 

required) (3 core 0,5mm

2.

Intercom cable (n1 + 6 core) to 

multistranded)

house.

7.

Intercom cable (n2+2 core 0,5mm

3.

Slave motor cable (if required) (3 

2

multistranded) to gate station.

core 2,5mm  + 3 core 0,5mm
multistranded).

n1 = number of cores required by intercom.

n2 = number of cores required by intercom.

2

S

ET

 

UP

 

THE

 G

ATE

 O

RIGIN

!
!
!
!

Release the manual override and close the gate(s).

Use the origin tool and line up marks as in figure 10.  

(IM

 page 28

)

Open gate ½ way and 

unscrew

 the manual release mechanism.  

(IM

 

page 28).

Figure 10 Origin Setup

Setup Tool

Manual Release
Mechanism

S

ETTING

 

THE

 G

ATE

 O

RIGIN

4

S

ELECT

 

EITHER

 M

ASTER

 

OR

 S

LAVE

 S

ETUP

G

ET

 I

NTO

 P

ROGRAMMING

 M

ODE

3

5

S

ET

 

THE

 G

ATE

 L

IMITS

!
!

!

!

Remove all power.  

(IM

 page 28)

Fit the SET link.

Reapply power 

!

!

Press and hold the TEST button, release after 1 flash of L1.         

Then again, press and hold the TEST button, and release after 1 or 2 
flashes of the STATUS LED.  (1 Flash=master, 2 Flashes=slave) (

Installa-

tion Manual

 page 29)

!
!
!
!
!

!
!

!

Press and hold TEST until the gate is closed, and then release.

NB:

 THE GATE MUST CLOSE.  IF IT OPENS :

Release the TEST button.
Swap the respective motor wires.
Press  and  hold  TEST  until  gate  is  closed,  and  then 
release.  

Press and hold TEST until gate is open, and then release.
Press and release TEST (When setting up the MASTER gate, it will close and 
then open to pedestrian. 

IM page 29

). 

If setting up the master gate, press and release TEST once more to complete 
the setup (The MASTER gate will open fully, and the SLAVE gate will move 
slightly).

!
!
!
!

Determine what features are required (See Table 2).  (

IM

 page 47)

Get into programme mode (as in Step 3), or continue from Step 5.

To select the Feature to Change:  (

IM

 page 31)

Press and hold

 the TEST button while monitoring L1:

Example of how to select the AUTOCLOSE feature:

The L1 light will flash once and pause,

Then flash twice and pause ...

6

S

ETTING

 A

DDITIONAL

 F

EATURES

 (

OPTIONAL

)


background image

10

11

* Increase cable thickness if pillar lights are to be installed.
† Screened cable is always recommended to provide better protection against lightning - earth one end 

of screening.

CABLE REQUIREMENTS

1.

220V AC mains cable (3 core LNE 

4.

Radio receiver cable (3 core 0,5mm

2

0,5mm )*†, via mains isolator switch

multistranded).

Or

5.

Pedestrian key switch (if required) (2 

core 0,5mm multistranded).

Low voltage 16V AC battery charger 

2

supply (2 core 1,5mm )†.

6.

Infrared beams or safety edge (if 

required) (3 core 0,5mm

2.

Intercom cable (n1 + 6 core) to 

multistranded)

house.

7.

Intercom cable (n2+2 core 0,5mm

3.

Slave motor cable (if required) (3 

2

multistranded) to gate station.

core 2,5mm  + 3 core 0,5mm
multistranded).

n1 = number of cores required by intercom.

n2 = number of cores required by intercom.

2

S

ET

 

UP

 

THE

 G

ATE

 O

RIGIN

!
!
!
!

Release the manual override and close the gate(s).

Use the origin tool and line up marks as in figure 10.  

(IM

 page 28

)

Open gate ½ way and 

unscrew

 the manual release mechanism.  

(IM

 

page 28).

Figure 10 Origin Setup

Setup Tool

Manual Release
Mechanism

S

ETTING

 

THE

 G

ATE

 O

RIGIN

4

S

ELECT

 

EITHER

 M

ASTER

 

OR

 S

LAVE

 S

ETUP

G

ET

 I

NTO

 P

ROGRAMMING

 M

ODE

3

5

S

ET

 

THE

 G

ATE

 L

IMITS

!
!

!

!

Remove all power.  

(IM

 page 28)

Fit the SET link.

Reapply power 

!

!

Press and hold the TEST button, release after 1 flash of L1.         

Then again, press and hold the TEST button, and release after 1 or 2 
flashes of the STATUS LED.  (1 Flash=master, 2 Flashes=slave) (

Installa-

tion Manual

 page 29)

!
!
!
!
!

!
!

!

Press and hold TEST until the gate is closed, and then release.

NB:

 THE GATE MUST CLOSE.  IF IT OPENS :

Release the TEST button.
Swap the respective motor wires.
Press  and  hold  TEST  until  gate  is  closed,  and  then 
release.  

Press and hold TEST until gate is open, and then release.
Press and release TEST (When setting up the MASTER gate, it will close and 
then open to pedestrian. 

IM page 29

). 

If setting up the master gate, press and release TEST once more to complete 
the setup (The MASTER gate will open fully, and the SLAVE gate will move 
slightly).

!
!
!
!

Determine what features are required (See Table 2).  (

IM

 page 47)

Get into programme mode (as in Step 3), or continue from Step 5.

To select the Feature to Change:  (

IM

 page 31)

Press and hold

 the TEST button while monitoring L1:

Example of how to select the AUTOCLOSE feature:

The L1 light will flash once and pause,

Then flash twice and pause ...

6

S

ETTING

 A

DDITIONAL

 F

EATURES

 (

OPTIONAL

)


background image

Table 2 Controller Functions Menus and Submenus

FEATURE

DESCRIPTION

Auto-close

Auto-close Time

Gate Limit Settings

-

See detailed instructions on page 29

1

2

3

STATUS or COUNT

DESCRIPTION

-

ON

15 seconds (Default)

1 Flash = 1 second

-

OFF (Default)

FEATURE

NUMBER

COUNT

VALUE

-

-

Mode of Operation

Pedestrian Auto-close

4

5

-

STANDARD (Default)

1 Flash = 1 second

5 seconds (Default)

-

CONDOMINIUM

PIRAC

REVERSING

Delay on master closing

Collision Counter

Leaf Delay Select

Leaf delay time /

Solenoid Strike Time

Delay on slave opening

1 Flash = 1 second

1 Flash = 1 count

4 counts (Default)

2 seconds (Default)

Delay on slave opening & master closing

Delay off (Default)

-

-

-

-

-

12

13

14

Preflashing

Preflash Time

Collision Sensitivity

Auto-close Override

Positive Close Mode

MODE 1

HIGH (Default)

ON

1 Flash = 1 second

1 Flash = 1 second

3 second (Default)

2 seconds (Default)

MEDIUM

OFF (Default)

LOW

MODE 2

MODE 3

OFF (Default)

-

1

-

2

STATUS

VALUE

3

4

1

2

-

-

1

1

1

1

2

3

2

2

2

3

3

4

4

-

 -

-

-

-

-

-

-

-

-

-

-

-

Courtesy Light

10

11

7

8

9

6

1 Flash =  10  seconds

120 seconds (Default)

!

!

!

At  this  moment  release  the  TEST  button  to  select  feature           

number 2.  (L2 will turn off, and L1 will keep on flashing 2 times 
and pausing to indicate that feature number 2 is selected).

NOTE:

 The STATUS of the Feature is not changed yet, the 

feature has only been selected to be changed!

If  an  incorrect  Feature  is  selected,  then  remove  and  re-

apply power and repeat the procedure.

To change the STATUS value of a Feature:  (

IM

 page 31)

Press  and  hold

  the  TEST  button  while  monitoring  the 

STATUS light:

(Continues from above example to set outoclose to ON status).

The L1 light will flash once and pause,
At  this  moment 

release  the  TEST

  button  to  give  a 

STATUS value of 1.  The AUTOCLOSE feature has been set to                    

ON 

NOTE:

  Only  after  setting  the  STATUS,  would  the 

AUTOCLOSE be turned ON.

(L2 will come back on, indicating that the STATUS has been 

set.)

To change the COUNT value of a Feature:  (

IM

 page 31)

Press  and  hold

  the  TEST  button  while  monitoring  the 

STATUS light:
After a slight pause, the STATUS light will start flashing 
regularly:

               Flash (1), Flash (2), Flash (3), Flash (4), Flash (5),
               Flash (6) ................  Flash (9), Flash (10).
At this moment release the TEST button to give a COUNT 

value of 10.  This could for example be the preflash time.

(L2 will come back on, indicating the COUNT value has 

been set). 

!

Remove the SET link.

7

E

XIT

 P

ROGRAMMING

 M

ODE

10

11

CP75 Controller Functions

CP75 Controller Functions


background image

Table 2 Controller Functions Menus and Submenus

FEATURE

DESCRIPTION

Auto-close

Auto-close Time

Gate Limit Settings

-

See detailed instructions on page 29

1

2

3

STATUS or COUNT

DESCRIPTION

-

ON

15 seconds (Default)

1 Flash = 1 second

-

OFF (Default)

FEATURE

NUMBER

COUNT

VALUE

-

-

Mode of Operation

Pedestrian Auto-close

4

5

-

STANDARD (Default)

1 Flash = 1 second

5 seconds (Default)

-

CONDOMINIUM

PIRAC

REVERSING

Delay on master closing

Collision Counter

Leaf Delay Select

Leaf delay time /

Solenoid Strike Time

Delay on slave opening

1 Flash = 1 second

1 Flash = 1 count

4 counts (Default)

2 seconds (Default)

Delay on slave opening & master closing

Delay off (Default)

-

-

-

-

-

12

13

14

Preflashing

Preflash Time

Collision Sensitivity

Auto-close Override

Positive Close Mode

MODE 1

HIGH (Default)

ON

1 Flash = 1 second

1 Flash = 1 second

3 second (Default)

2 seconds (Default)

MEDIUM

OFF (Default)

LOW

MODE 2

MODE 3

OFF (Default)

-

1

-

2

STATUS

VALUE

3

4

1

2

-

-

1

1

1

1

2

3

2

2

2

3

3

4

4

-

 -

-

-

-

-

-

-

-

-

-

-

-

Courtesy Light

10

11

7

8

9

6

1 Flash =  10  seconds

120 seconds (Default)

!

!

!

At  this  moment  release  the  TEST  button  to  select  feature           

number 2.  (L2 will turn off, and L1 will keep on flashing 2 times 
and pausing to indicate that feature number 2 is selected).

NOTE:

 The STATUS of the Feature is not changed yet, the 

feature has only been selected to be changed!

If  an  incorrect  Feature  is  selected,  then  remove  and  re-

apply power and repeat the procedure.

To change the STATUS value of a Feature:  (

IM

 page 31)

Press  and  hold

  the  TEST  button  while  monitoring  the 

STATUS light:

(Continues from above example to set outoclose to ON status).

The L1 light will flash once and pause,
At  this  moment 

release  the  TEST

  button  to  give  a 

STATUS value of 1.  The AUTOCLOSE feature has been set to                    

ON 

NOTE:

  Only  after  setting  the  STATUS,  would  the 

AUTOCLOSE be turned ON.

(L2 will come back on, indicating that the STATUS has been 

set.)

To change the COUNT value of a Feature:  (

IM

 page 31)

Press  and  hold

  the  TEST  button  while  monitoring  the 

STATUS light:
After a slight pause, the STATUS light will start flashing 
regularly:

               Flash (1), Flash (2), Flash (3), Flash (4), Flash (5),
               Flash (6) ................  Flash (9), Flash (10).
At this moment release the TEST button to give a COUNT 

value of 10.  This could for example be the preflash time.

(L2 will come back on, indicating the COUNT value has 

been set). 

!

Remove the SET link.

7

E

XIT

 P

ROGRAMMING

 M

ODE

10

11

CP75 Controller Functions

CP75 Controller Functions


background image

M

SS1 SS2 SS3 COM COM SOL 12V

PSU
STD

(LED)

STATUS

LIGHT

SLAVE

-BATT+

SLAVE FUSE 16A S/B

AUX FUSE 3A F/B

LIGHT

FUSE

3A F/B

MASTER FUSE 16A S/B

MASTER

RED

BLACK

PURPLE

RED

BLACK

ORANGE

3-WAY

CONNECTOR

3-WAY

CONNECTOR

TO ORIGIN

SENSOR ON

SLAVE

MOTOR

TO COUNTER

SENSOR ON

SLAVE

MOTOR

ONLY FITTED IN DOUBLE SWING GATE SYSTEMS

M

SENSOR

MOTOR

SLAVE

SS1

SS2

SS3

CP75A

6-WAY

CONNECTOR

2

1

4

3

L
N
E

NEUTRAL

LIVE

CP84ER5V01

AUXILIARY

SUPPLY

220V AC

MAINS IN

Slave Operator

Figure 11 CP75 Controller Connections

10

11

CP75 Basic Controller Connections

CP75 Basic Controller Connections

Trigger Connections

Trigger Connections

Figure 12 CP75 Controller Trigger Connections

NEG

NEG

NEG

+12V

+12V/24V

+12V/24V

PUSHBUT

TON

FOR SWITCHING

PILLAR LIGHT (N/0)

HOLIDA

Y L

OCKOUT

SWITCH (N/C)

ST

A

TUS LED

PEDESTRIAN

KEYSWITCH (N/O)

(RETURN SPRING)

COM

COM

COM

NC

NC

NC

NO

NO

12V or 24V

NO

LOOP

LOOP DETECTOR

IRB RECEIVER

IRB Tx

RADIO RECEIVER

R

EM

O

TE C

O

N

TR

O

L C

IR

C

U

IT

R

Y

PILL

AR LIGHT P

USHBUTTON

H

O

LI

D

A

Y L

O

C

K

O

U

T K

EY

S

W

IT

C

H

PEDESTRIAN KEYSWITCH

IN

F

R

A R

E

D B

E

A

M C

IR

C

U

IT

R

Y

FREE EXIT CIRCUITR

Y

SOLENOID

LOCK

COM COM SOL 12V TRG IRB FRX LED PED LCK SET

SS3

For a detailed description of 
terminal  functions,  refer  to 
D E S C R I P T I O N   O F  
TERMINAL  FUNCTIONS  on 
page  45  of  the  Installation 

!

Explain to the user how to 

SAFELY

 operate the gate.  (

IM

, page  51.)

P

ERFORM

 I

NSTALLATION

 H

ANDOVER

8


background image

M

SS1 SS2 SS3 COM COM SOL 12V

PSU
STD

(LED)

STATUS

LIGHT

SLAVE

-BATT+

SLAVE FUSE 16A S/B

AUX FUSE 3A F/B

LIGHT

FUSE

3A F/B

MASTER FUSE 16A S/B

MASTER

RED

BLACK

PURPLE

RED

BLACK

ORANGE

3-WAY

CONNECTOR

3-WAY

CONNECTOR

TO ORIGIN

SENSOR ON

SLAVE

MOTOR

TO COUNTER

SENSOR ON

SLAVE

MOTOR

ONLY FITTED IN DOUBLE SWING GATE SYSTEMS

M

SENSOR

MOTOR

SLAVE

SS1

SS2

SS3

CP75A

6-WAY

CONNECTOR

2

1

4

3

L
N
E

NEUTRAL

LIVE

CP84ER5V01

AUXILIARY

SUPPLY

220V AC

MAINS IN

Slave Operator

Figure 11 CP75 Controller Connections

10

11

CP75 Basic Controller Connections

CP75 Basic Controller Connections

Trigger Connections

Trigger Connections

Figure 12 CP75 Controller Trigger Connections

NEG

NEG

NEG

+12V

+12V/24V

+12V/24V

PUSHBUT

TON

FOR SWITCHING

PILLAR LIGHT (N/0)

HOLIDA

Y L

OCKOUT

SWITCH (N/C)

ST

A

TUS LED

PEDESTRIAN

KEYSWITCH (N/O)

(RETURN SPRING)

COM

COM

COM

NC

NC

NC

NO

NO

12V or 24V

NO

LOOP

LOOP DETECTOR

IRB RECEIVER

IRB Tx

RADIO RECEIVER

R

EM

O

TE C

O

N

TR

O

L C

IR

C

U

IT

R

Y

PILL

AR LIGHT P

USHBUTTON

H

O

LI

D

A

Y L

O

C

K

O

U

T K

EY

S

W

IT

C

H

PEDESTRIAN KEYSWITCH

IN

F

R

A R

E

D B

E

A

M C

IR

C

U

IT

R

Y

FREE EXIT CIRCUITR

Y

SOLENOID

LOCK

COM COM SOL 12V TRG IRB FRX LED PED LCK SET

SS3

For a detailed description of 
terminal  functions,  refer  to 
D E S C R I P T I O N   O F  
TERMINAL  FUNCTIONS  on 
page  45  of  the  Installation 

!

Explain to the user how to 

SAFELY

 operate the gate.  (

IM

, page  51.)

P

ERFORM

 I

NSTALLATION

 H

ANDOVER

8


background image

Sharecall 0860-CENTURION

(Sharecall number applicable when dialed from within South Africa only)

(Omit (0) when dialing from outside South Africa)

or visit www.centsys.co.za

for details of your nearest agent

For technical support, contact:

South African Branches and Regional Distributors:

Other Countries:

Johannesburg Central/West Rand. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 011-699-2400
Johannesburg  East-Rand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 011-397-6401
Durban . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  031-701-9583
Nelspruit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  013-752-8074/5
Pretoria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 012-349-1745
Cape Town . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 021-552-9425
Port Elizabeth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 041-581-6994/5
East London . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 043-743-4923
Bloemfontein . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 051-448-1714
Kimberly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 053-832-3231
Vereeniging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 016-422-5667

Please refer to our website: www.centsys.co.za

Centurion Systems (Pty) Ltd Head Office:

Tel: +27 (0)11-699-2400, Fax: +27 (0)11-704-3412 or (0)11-462-6669

148 Epsom Avenue, North Riding

P.O. Box 506, Cramerview, 2060

South Africa

Latest Revision: 28.01.2009     

Document Ref.: 1150.D.01.0015_1

Master address page: 0000.D.01.0004_5 

© 2007 Centurion Systems (Pty) Ltd.

Product Code: