SWH-2109F 

 

7 PORT 10/100BASE-TX ETHERNET SWITCH 

WITH 2 PORT 100BASE-FX UPLINK FIBER 

(FIBER REDUNDANCY OPTION)   

 

 

User's Guide 

Ver: 1.0 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 1 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

Trademarks

 

CTS is a registered trademark of Connection Technology Systems Inc.   

Contents subject to revise without prior notice. 

All other trademarks remain the property of their owners. 

 

Copyright Statement 

Copyright 

©

 Connection Technology Systems Inc.

 

This publication may not be reproduced as a whole or in part, in any way whatsoever 

unless prior consent has been obtained from Connection Technology Systems Inc. 

 

FCC Warning 

 

This equipment has been tested and found to comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC Rules. These limitations are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates uses and can radiate radio frequency energy and, if no installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the following 
measures: 
 

„

 

Reorient or relocate the receiving antenna. 

       

„

 

Increase the separation between the equipment and receiver. 

       

„

 

Connect the equipment into a different outlet from that the receiver is connected. 

       

„

 

Consult your local distributors or an experienced radio/TV technician for help. 

       

„

 

Shielded interface cables must be used in order to comply with emission limits. 

 
Changes or modifications to the equipment, which are not approved by the party 
responsible for compliance, could affect the user’s authority to operate the equipment. 
 
Copyright © 1999 All Rights Reserved.   
 
Company has an on-going policy of upgrading its products and it may be possible that 
information in this document is not up-to-date. Please check with your local distributors 
for the latest information. No part of this document can be copied or reproduced in any 
form without written consent from the company. 
 
Trademarks: 
All trade names and trademarks are the properties of their respective companies

   

 2 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

Table of Contents 

 

1.  Unpacking Information 

 

2.    Introduction to 9 Port NWay Switching Hub 

2.1  General 

Description 

2.2  Key 

Features 

2.3 

 

The Front Panel 

2.3.1  

System 

LEDs 

2.3.1.1

 

Power LED 

2.3.2

 

                Port LEDs 

2.3.2.1

 

100M LED 

2.3.2.2

 

Link/Act LED 

2.3.2.3

 

FDX/COL LED 

2.3.3 

Fiber Port LED 

2.3.3.1

 

TP/Fiber LED 

2.3.3.2

 

Status LED 

2.3.3.3

 

Redundancy LED 

2.4 

 

The Rear Panel 

2.4.1

 

Power Connecting 

2.4.2

 

DIP switch 

2.4.3

 

Fiber Port 

 

  3.    Installing and Using 9 Port NWay Switching Hub 

3.1 

 

Installing the 9 Port NWay Switching Hub 

3.1.1

 

Desktop Installation 

3.1.2    

Installing Network Cables 

3.1.2.1

 

Station Connection with Twisted-Pair Cable 

3.1.2.2

 

Station Connection with Fiber Optic Cable 

3.1.2.3

 

Switch to Switch Connection with Twisted-Pair Cable 

3.1.2.4

 

Switch to Switch Connection with Fiber Optic cable   

3.2

 

Installing Redundant Fiber Port 

 

3.2.1         Redundant Installation 

 

4.

 

Switching Operation 

4.1 

 

MAC Address Table & Learning 

4.2  Filtering 

and 

Forwarding 

4.3 

 

Store and Forward 

4.4  SNMP 

proxy 

support 

 

5.

 

Product Specifications 

 

1.  Unpacking Information 

 3 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

 

Thank you for purchasing the 9-port SWH-2109F NWay switching hub. Before you 

start, please check all the contents of this package.     

 

The product package should include the following:   

               

1.    One 9-port NWay switching hub 

 

2.  One external power supply 
 

3.

 

Rubber foot   

 

4.

 

User’s manual 

 

5.

 

Cable Holder 

 

 

 

 4 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

 

2.    Introduction to 9 Port NWay Switching Hub 

 

2.1 General Description 

 

This device is a powerful, high-performance Ethernet / Fast Ethernet Switch with 

two fiber uplink ports. Twisted pair ports are capable of 10 or 100Mbps auto-negotiation 

operation (N-Way). 100Mbps according to the 100Base-FX standard are supported on 
the fiber interface. The SWH-2109F is an ideal solution for micro-segmenting large 

networks into smaller sub-networks for overall improved performance, so enabling the 

most demanding bandwidth multimedia and imaging applications. Moreover, the 

10/100Mbps auto-sensing capability provides an easy way in which to move from a 

10Mbps to a 100Mbps network.   

Compared with shared 10Mbps or 100Mbps networks, this N-Way switch delivers a 

dedicated 10/100Mbps connection to every attached client with no bandwidth congestion 
problems. Store-and-forward switching modes guarantee low latency and fast data 

transmission. Full-duplex mode allows the simultaneous transmission and reception of 

frames without the risk of collisions as well as a doubling of the network bandwidth.   

 

For network connection: 

 

The switching hub can use the following types of cabling: 
 

„

 

10BASE-T Category 3, 4 or 5 UTP/STP 

 

„

 

100BASE-TX Category 5 UTP/STP 

 

Fiber Optic: 

50/125, 62.5/125, or 100/140

µ

m multimode 

 

 

 

8.3/125, 8.7/125, 9/125 or 10/125

µ

m single mode 

 

Category 5 cable is preferred to be used with this product in structured wiring 

environments. This will ensure correct operation of all ports at 10Mbps or 

100Mbps. 

 

2.2 Key Features 

 

The SWH-2109F switching hub provides the following key features: 

 

ƒ

 

2K MAC address table, 1M Bit  buffer memory 

ƒ

 

8 RJ-45  (STP) ports  for 10/100Base-T/TX  and  two 100Base-FX ports 
(TP port 8 can alternate FX Port 1) 

ƒ

 

Redundant operation for fiber port Complies with IEEE802.3 and IEEE802.3u

 5 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

 standards 

ƒ

 

Supports N-Way protocol for 10Base-T and/or 100Base-TX connections Full/
Half duplex mode operation  

ƒ

 

Small size 

ƒ

 

Store-and-forward switching mechanism  

ƒ

 

Automatic  filtering of  fragmented and  CRC error packets 

ƒ

 

Extensive LED indicators for network diagnostics 

ƒ

 

External power adapter 

ƒ

 

State Monitor - Model/Media/Link/Speed/Duplex/Activity 

ƒ

 

Enhanced Port Monitor – Port Traffic Counter 

ƒ

 

S/W Port Configuration - Support Auto/Speed/Duplex/Auto 

MDIX/MDIX 

ƒ

 

Support SNMP management 

ƒ

 

Support Telnet management 

ƒ

 

Support console management 

ƒ

 

IP Configuration 

ƒ

 

DHCP 

ƒ

 

IP Security 

ƒ

 

Time server Configuration 

ƒ

 

User Authentication 

ƒ

 

Trap Configuration 

ƒ

 

FTP/TFTP firmware upgrade 

ƒ

 

Support 802.1Q Tagged VLAN 

ƒ

 

Port rate limiting included Broadcast storm 

ƒ

 

3 options but only one enable(port based Priority and 802.1P Priority supported and 
TOS priority supported) 

ƒ

 

QOS support with four traffic classes   

 

2.3

 

The Front Panel 

 

The front panel of the switching hub is shown below. 

 

 6 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

 

The auto-negotiation feature of the switching hub allows port 1 to port 8 running at 

one of the following four operation modes: 

1. 100Mbps full-duplex 

2. 100Mbps half-duplex 

3. 10Mbps full-duplex 

4. 10Mbps half-duplex 

 

Port F1 and F2 can be used as fiber uplink ports for connecting to another fiber 

optic device or operation as redundant function. You can easy extend the distance from 

2,000m to 100,000m by multimode or single mode fiber cable. 

 

Warning:    The RJ-45 ports are shielded data sockets. They can not be used as 

telephone sockets. Only R-J45 plugs are allowed to connect these sockets. 

 

2.3.1 System LEDs 

System LED indicators are located on the front panel for showing the operating 

status of the whole device. 

         

2.3.1.1

 

Power LED 

This indicator lights green when the hub is receiving power; otherwise, it is off. 

 

2.3.2 Port LEDs 

Port LED indicators are located on the front panel for showing the operating status 

of each port. 

 

2.3.2.1 Speed LED 

The Speed LED indicates the link speed of each port. If the LED lights green then 

the connection speed is 100Mbps, off for 10Mbps.   

 
2.3.2.2 Link/Act LED 

Every port has a Link/Activity LED. Steady green (link state) indicated that the port 

has good linkage to its associated device. Flashing green indicates that the port is 

receiving or transmitting data between its associated devices.   

 

If the port is connected but the Link/Activity LED is dark, check the following items: 

 
1. The switching hub and the connected device’s power are on or not 

2. The port’s cable is firmly seated in its connectors in the switching hub and in the 

associated device. 

3. The connecting cable is good and with correct type   

4. The connecting device, including any network adapter is functioning. 

 

From the Speed LED and Link/Activity, we could judge the connection speed as 
following: 

 

 7 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

Speed LED 

Link/Activity LED 

Status 

Off Off No 

Connection 

Off 

Green 

Connect as 10Mbps 

Green Green Connect 

as 

100Mbps 

 

2.3.2.3

 

FDX/COL LED 

 

A collision occurs when two stations within a collision domain attempt to transmit 

data at the same time. Intermittent flashing amber of the collision LED is normal; the 

contending adapters resolve each collision by means of a wait-then-retransmit algorithm. 
Frequency of collisions is an indicator of heavy traffic on the network.   

 

If the FDX/COL light green which means the port is under full-duplex operation or 

dark for half-duplex mode. The following table is a summary of Port LEDs. 

LED  

Operation 

100M 

100Mbps (Green), 10Mbps (Off) 

Link/Act 

Link is present (Green), Activity (Blinking Green) 

FDX/COL 

Full-Duplex (Amber), Half-Duplex (Off), COL (Blinking Amber) 

 

2.3.3

 

Fiber Port LED   

The port F1 and F2 are fiber uplink ports with redundant function. The Status and 

Redundant LEDs indicate enough information in Fiber port operation. 

 

2.3.3.1 TP / Fiber LED 

The TP/Fiber LED indicates TP8 and F1 link status, if TP LED on it indicates the 

port 8 links to TP or F1 link to Fiber. 

 

 

NOTE: 

The TP Port 8 default priority is higher than Port F1, if user link both TP 

port7 and Port F1, it will switch to TP Port 8. 

 

 

2.3.3.2 Status LED 

Reserve 
 

2.3.3.3 Redundancy LED 

 

The “Redundancy” LED will be “Green” when the “Redundant “function enable and 

F1/F2’s with fiber link stage.   

 

Redundant 

Off 

On On On On 

F2Link 

Off 

On On Off Off 

F1 Link 

Off 

On Off On Off 

F2 Redundancy

 

Off Green Green  Off 

Off 

F1 Redundancy

 

Off Off  Off Green Off 

 8 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

 

NOTE: 

The default primary is Port F2 and Secondary is Port F1. 

 

2.4 The Rear Panel 

The rear panel of the hub is shown below 

 

2.4.1 Power Connecting 

Plug the circle end of the power adapter firmly into the rear panel of the switching 

hub, and the other end into an electric service outlet then the system is ready. 

 

2.4.2

 

DIP Switch 

The DIP switch reserved all of functions. 

 

2.4.3

 

Fiber Port 

The F1 and F2 are Fiber Optic link ports. 

 

2.4.4

 

Diag button 

Reserves 

   

3.    Installing and Using 9 Port NWay Switching Hub   

         

3.1 Installing the 9 Port NWay Switching Hub 

The SWH-2109F does not require software configuration. Users can immediately 

use any of the features of this product simply by attaching the cables and turning the 

power on. 

   

3.1.1 Desktop Installation 

To locate the switching hub on the desktop and place the hub on a clean, flat desk 

or table closes to a power outlet. Plug in all network connections and the power cord, and 

then the system is ready. 

 

When deciding where to put the switching hub then you must ensure: 

„

 

It is accessible and cables can be connected easily 

„

 

Power cord holder was kept in package if consider to fix power cord. It could lock 
aside from consol port. 

„

 

Cabling is away from: 

        Sources of electrical noise such as radios, transmitters and broadband amplifiers 

        , Power lines and fluorescent lighting fixtures. 

„

 

Water or moisture can not enter the unit 

„

 

Air flow around the unit and through the vents in the side of the case is not         

restricted (company recommend that you provide a minimum of 25mm inch 
clearance) 

To prolong the operational life of your units: 

 9 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

„

 

Never stack units more than eight high if freestanding. 

„

 

Do not place objects on top of any unit or stack 

„

 

Do not obstruct any vents at the sides of the case 

 

3.1.2 Installing Network Cables 

After placing the hub on the desktop, then we need to know how to connect the 

device to network. 

 

5.1.2.1

 

Station Connections with Twisted-Pair Cable 

Connect each station to the switching hub by a twisted-pair straight cable 

(10BASE-T or 100BASE-T cables). Plug one RJ-45 connector into a front-panel port of 

the hub, and plug the other RJ-45 connector into the station’s network adapter. 

 

5.1.2.2

 

Station Connections with Fiber Cable 

Connect station to switching hub fiber port by a fiber cable. Plug fiber cable 

connector into to rear panel fiber port and plug the other fiber connector into the other 
fiber device. 

 

3.1.2.3 Switch to Switch Connections with Twisted-Pair Cable 

In making a switch to switch connection, you could use port 1to port 6 to connect 

another switch with crossover cable.   

 

3.1.2.4 Switch to Switch Connections with Fiber Cable 

In making a switch to switch connection, you could use port 7to port 8 to connect 

another switch with fiber cable. And the distance can be extending from 2,000m to 

100,000m with multimode or single mode cable. 

 

5.2

 

Installing Redundant Fiber Port 

The SWH-2109F built in one pair redundant fiber port function in port F1 and port 

F2. In the event of a failure in the primary connection (port F2), a fully redundant 
secondary connection (port F1) is made available to the failed connection.   

             

3.2.1

 

Redundant Installation 

Due to software function is complete and could use switch configuration option set 

up fiber redundant and F1 and F2 link fiber cable. You can monitor redundant function 

operation status from front panel LED indication. 

 
 

NOTE: 

Strong recommend user must link SWH-2109F with “Redundant 

Function” device if want to setup SWH-2109F under Fiber Redundant function. 
The SWH-2109F is not supported full Fiber Redundant function if link with 
non-redundant function base device. 

 

 

 

 

 10 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

4.  Switch Operation 

 

5.1

 

MAC Address Table and Learning 

 

The switching hub is implemented with a MAC address table which is composed of 

many entries. Each entry is used to store the address information of network nodes on 
the network, including MAC address, port ID, etc. The information is the most important 

base to do packet filtering and forwarding. 

 

When one packet comes in from any port, the switching hub will learn the source 

address, port ID, and the other related information in address table. Therefore, the 

content of the MAC table will update dynamically.   

 

5.2

 

Filtering and Forwarding 

 

When one packet comes in from any port of the switching hub, it will check the 

destination address besides the source address learning. The hub will look up the 

address table for the destination address. If not found, this packet will be forwarded to all 

the other ports except the port which this packet comes in. If found, and the destination 

address is located at different port from this packet comes in, the packet will be 
forwarded to the port where this destination address is located according to the 

information of address table. But, if the destination address is located at the same port as 

this packet comes in then this packet will be filtered.   

     

4.3 Store and Forward 

 

Store-and-forward is one kind of packet-forwarding methodology. As a 

store-and-forward switching hub, it will store the complete packet in the internal buffer 
and do the complete error checking before transmitting to the network. Therefore, no 

error packets will disturb the network. It is the best choice when a network needs 

efficiency and stability.   

 

5.  Product Specifications 

 

Standard 

IEEE802.3, 10BASE-T 

IEEE802.3u, 100BASE-TX/FX 

Interface 

RJ-45 x8 NWay switching ports 

FO-SC or ST fiber connector x 2   

Cable Connections 

RJ-45 (10BASE-T) : UTP Category 3,4,5     

RJ-45 (100BASE-TX) : UTP Category 5 
Fiber Optic :50/125, 62.5/125, or 100/140

µ

m multimode 

 

  8.3/125, 8.7/125, 9/125 or 10/125

µ

m single mode 

                                                           

Network Data Rate 

Auto-negotiation (10Mbps, 100Mbps) 

Transmission Mode 

Auto-negotiation (Full-duplex, Half-duplex) 

 11 

頁,共

 12 

 SWH-2109F 

V1.0 

 
 

 


background image

LED indications 

System 

Power x1   

Port 

100M 

Link/Activity 

FDX/COL 

Redundancy 

    PRI   

  SEC 

System Buffer Memory 

1M Bit 

MAC Address Table 

2K entries 

Filtering/Forwarding Rate  10Mbps: 14,880pps/14,880pps 

100Mbps: 148,800pps/148,800pps 

Emission 

FCC Class A, CE 

Dimensions 

240 X 155 X 34 mm 

Weight 

1.1 KG 

Operating Temperature 

0

0

 ~ 50

0

Storage Temperature 

-20

0

 ~ 60

0

Operating Humidity 

10% - 90% 

External Power Adapter    AC IN 100~240 V AC, 50/60 Hz AC 

DC Out 12V DC

 

1.2A 

 

 