Technical Specifications sat 801

Dual Channel 
Pulse Oximeter

The new sat 801

... introducing 

Delta 

Pulse Oximetry

Dual Channel 
Pulse Oximeter

Documentation

  

PC reporting software 

satview

 for 

easy and fast analysis and complete 
monitoring documentation.

Cost-effective solution, easy opera-
tion and clear illustration of patient 
compliance, monitoring periods, 
alarm events incl. database.

sat 801

sat 801

„Because every baby 
  deserves a healthy start!“

Dimensions:

128 x 85 x 46 mm

Weight:

230 g incl. battery

Mains supply:

100 -230 V / 50 - 60 Hz

DC supply:

5 V

Battery autonomy:

18 hours

Recharging:

4 hrs 75% - 6 hrs 100 %

Operation:

+5°C – + 40°C

Storage:

-20°C – + 70°C

SpO

2

 technology:

Masimo SET

©

SpO

display range:

0 - 100 %

SpO

2

 accuracy:

70 - 100 %

no motion: 

+/- 3 digits

motion, adults & pediatrics:

+/- 2 digits

motion, neonates:

+/- 3 digits

low perfusion, adults & peds: +/- 2 digits

low perfusion, neonates:

+/- 3 digits

Pulse rate display range:

25 - 240 bpm

Pulse rate accuracy:

25 - 240 bpm

no motion:

+/- 3 digits

motion:

+/- 5 digits

low perfusion:

+/- 3 digits

Interface:

USB, external microSD

MDD classification:

IIa, CE 0197

Accessories:

 

LNC-1 adapter cable
Masimo ReSposable sensor line
Masimo LNCS sensor line
Carrying case
Table stand   
Mounting clamp

Standard package contents:

 

sat 801            

36-8002

Charger 36-5005
Instructions for use

 


background image

Step 1

 + USB interface

+ proven Masimo SET

TM

   performance

+ easy-to-operate

+ latest LiIon battery  
technology

sat 801

Pulse Oximetry is special.

 + integrated 
    rubber boots

 + plethysmogram     

for both channels

 + mains & battery
    powered

Two-piece design includes a reusable AND a disposable sensor

Re

usable +Di

sposable

=

ReSposable

for a Nationwide Newborn 
Screening Standard to 
improve detection of critical 
congenital heart defects. 
Also more and more in 
the rest of the world, this 
screening method becomes 
mandatory.

What is Delta 
Pulse Oximetry? 

Delta Pulse Oximetry is the 
unique method of obtaining 
simultaneous differential Masimo 
SET readings, derived by dual 
channel pulse oximetry at 
pre- and postductal spots.
This special configuration is well 
suited for the easy implementati-
on of the Screening Protocol for 
the systematic detection of Criti-
cal Congenital Heart Defects.

CCHD Screening

In the US, CCHD Screening is 
based on the recommendation 
of the U.S. Health & Human 
Services that outlined a strategy 

The sat 801

Δ

 has been specifically designed for the 

needs of Critical Congenital Heart Defect scree-
ning.

Combining the identical Gold Standard technology 
for simultaneous dual channel readings minimizes 
errors related to sequential readings and variations 
caused by different pulse oximetry technologies.

Intuitive operation and a clear color-coded pre-
sentation provides reliable screening results in 
seconds.

sat 801

Pulse Oximetry is simple.

sat 801 

 

 : Better Design

sat 801 

 

 : Increased Accuracy 

sat 801 

 

 : Faster results

Delta (

Δ) 

is the fourth 

capital letter in the 
Greek alphabet. It 
is often used as a 
difference operator 
to describe change, 
because delta is the in-
itial letter of the Greek 
word „diaphorá“, 
meaning „difference“.

Step 1

Preductal Spot (Right Hand)

Place sensor on the outer lateral aspect of the right hand.

Step 3 

Obtain all three Readings at a time

Record both SpO

- and the DELTA readings.

Step 2

Postductal Spot (Left or Right Foot)

Place sensor on the outer lateral aspect of either foot.

Step 4

Assessment

NEGATIVE  Screen (Pass):

SpO

2

 

 95% in hand or foot

AND DELTA (hand-foot difference) 

 3%.

POSITIVE CCHD Screening Test Result:

 

   

SpO

2

 < 90% in hand OR foot,

OR 
3 repeated positive screens (SpO

2

 90-94% in the hand AND foot 

OR hand-foot absolute difference is > 3%)

Step 2

Step 3

LNC-1

 

connects to the sat 801

Δ

Reusable sensors

 

offer cost-effectiveness and 
environmental advantages

Disposable sensors

have the best performance, 
greatest ease of use and 
most comfort