Full Text Searchable PDF User Manual
B1+ User´s Guide
Snow Leopard Miner
B1+ User’s Guide
B1+ User´s Guide
Table of Contents
1. Product Overview
......................................................................................................................... 1
1.1 Miner B1+´s components
.................................................................................................... 1
1.2 Specifications
...................................................................................................................... 2
2. Starting Your Miner
....................................................................................................................... 3
2.1 Preparatory Work
................................................................................................................ 3
2.2 Connecting the Power Supply
............................................................................................. 3
3. Setting Up Your Miner
.................................................................................................................. 4
4. Monitoring Your Miner
................................................................................................................. 7
5. Administering Your Miner
............................................................................................................ 7
B1+ User´s Guide
1
Copyright@2018 Bitfily Technology Co., LTD. All Rights Reserved.
1. Product Overview
The miner B1+ is Bitfily´s new version in the Snow Leopard Miner series. It boasts an advanced
ASIC chip using 10nm technology and complies with restrict and reliable design and
manufacturing standards, completely surpassing the mainstream miners in the current market.
1.1 Miner B1+´s components
The miner B1+´s main components and controller front panel are shown in the following figures:
Controller
Cover plate
Controller PCI-e
Power Connector
Hash Board
PCI-e Power
Flexible Extension
Cables
Hash Board Housing
Rear Fan
Ethernet Port
Fault Indicator
Normal Operation Indicator
IP Set Push button
Reset Button
TF Card Slot
Front Fan
regulated power
supply socket
B1+ User´s Guide
2
Copyright@2018 Bitfily Technology Co., LTD. All Rights Reserved.
1.2 Specifications
ASIC chip
BFL1001-32core
Hash rate
24.5T±5%
quantity of chips
288PCS
Hash rate of a chip
86.7GH/s
Energy
efficiency of chip
0.09J/GH
Power consumption
of chip
7.5W/0.405V
Wall -power
consumption
2100W+10%
Rated voltage
14.5~15.5V
(
Hash Board
)
12V
(
Controller Board
)
Operating
ambient temp.
0℃~40℃
(32
℉
~104
℉
)
Operating ambient
humidity
5%RH~95%RH
,
non-condensation
Network linking
10/100/1000MBase-T Dimensions
(L)390mm*(W)149.5mm*(H)185mm
Noise
75dB
Net weight
8.5Kg
Functional Description
ETH port is used to connect the Ethernet cable.
The red and green lights indicate the operation status of the miner. When the green light twinkles, it indicates
OK; when the red light keeps on, it indicates fault.
Press and hold IP Report button from 2 seconds to 8 seconds to get the IP address of the miner. from 8
seconds to 15 seconds to change the IP mode,from dynamic address to static state address, or the opposite.
Press and hold Reset button more than 3 seconds to restore the default settings of the miner.
Warning
1.
Do not touch the rotating fan blades in case of
personal injury.
2.
Standard
B1+ power supply is recommended to avoid damage to
B1+ Miner
or
any
safety accident.
3.
The maximum power consumption of B1+
Miner is about 2250W. Please confirm whether your power
socket meets the power requirements of the mining machine.
4.
Do not spill water or other liquids onto B1+ Miner, especially the non-shell parts.
B1+ User´s Guide
3
Copyright@2018 Bitfily Technology Co., LTD. All Rights Reserved.
2. Starting Your Miner
2.1 Preparatory Work
Prepare a network cable, a Miner B1+, a power supply unit, an AC power cord and a
computer.
2.2 Connecting the Power Supply
Ten PCI-e connectors are located at the top of the Miner B1+ for connecting the PSU. Nine
PCI-e connectors are for the hash boards and each hash board has a set of three PCI-e connectors.
One PCI-e connector located on the controller is for the controller. (See figure 1 in part 1.1)
To connect the power supply
:
1)
Connect PSU power cable connectors to each of the eight PCI-e connectors on the top of
the miner and the PCI-e connector on the controller.
2)
Connect the network cable to the ETH port.
3)
Check whether the flexible extension cables and the fan connection cable and
regulated
power supply socket
on the top of the miner are connected properly.
4)
After all cables have been connected correctly, connect the AC power cord to the power
outlet.
After connecting the power supply, please check whether the miner operates as follows
:
1)
the front and rear fans operate normally;
2)
the green light on the controller twinkles;
3)
the green light on the ETH port keeps on and the orange one twinkles;
4)
the blue lights on the three sets of hash board PCI-e connectors keep on.
If the miner runs normally, you can move to the next step. If not, please troubleshoot the
miner.
B1+ User´s Guide
4
Copyright@2018 Bitfily Technology Co., LTD. All Rights Reserved.
3. Setting Up Your Miner
1)
Go to this site: https://pan.baidu.com/s/1c2HEx6w.
2)
Download the file: IP-Reporter.rar
3)
Extract the file.
4)
Install JAVA run time environment (if it is installed, skip this step): run JavaSetu
p8u151.exe
5)
Run the file: IP-Reporter.exe
6)
Press the
IP Set
button for more than two seconds and then the IP address will
be displayed in the IP-Reporter interface.
Statement
The file IP Reporter.zip is supported by Microsoft Windows only.
The default DHCP network protocol distributes IP addresses automatically.
The computer should be connected to the same LAN as the miner.
If the IP report function is broken, maybe you should turn off firewall.
B1+ User´s Guide
5
Copyright@2018 Bitfily Technology Co., LTD. All Rights Reserved.
7)
In your web browser, enter the IP address provided and proceed to login using the
username “admin” and password “123456”.
8)
In the
Network Setting
of Settings section, you can assign a Static IP address
(optional).
9)
Setting up the pool
. Click the Pool Setting in Settings section to set the options. Take
the Dpool as an example:
Pool URL: btc-hn.s.dpool.top
Port: 443 / 25 / 1800
Worker: set up according to the sub-account you create on the pool
Password: arbitrary password
After finishing the three settings, click Apply button.
B1+ User´s Guide
6
Copyright@2018 Bitfily Technology Co., LTD. All Rights Reserved.
10)
In the
Work Mode
of Settings section, you can set up the work mode of the
miner between Efficiency and Performance.
Statement
The Miner B1+ only supports the mining of pools using ASIC BOOST technology.
The Dpool is recommended.
The pool URL should use the node address where the miner is placed.
B1+ User´s Guide
7
Copyright@2018 Bitfily Technology Co., LTD. All Rights Reserved.
After finishing the three settings, click Config button.
4. Monitoring Your Miner
1)
Click
Miner Status
.
2)
Monitor your miner through the followings
:
Real-time hash rate: it shows the real-time hash rate of the miner in one minute.
Average hash rate: it shows the average value of hash rate produced by the
operating miner.
Working hour: it shows the uptime of the miner.
Fan: it respectively shows the rotating speeds of the front and rear fans as
well as the duty cycle.
Curve graph: it shows the hash rate fluctuation of corresponding hash board
from the moment it starts to work to the moment you check it.
5. Administering Your Miner
1)
Check your software version in
Dashboard
section.
In the example below, the miner is using software version: B1+_20180917_143358
B1+ User´s Guide
8
Copyright@2018 Bitfily Technology Co., LTD. All Rights Reserved.
2)
Upgrade your firmware
In
Upgrade
of Logs section, select a
.swu
formatted file and then click
Upgrade
button.
3)
Modifying your password
In
Password
of Logs section, input your current password and new password and then click
Statement
When the upgrade is complete, the miner system will reboot. Therefore, you need to
refresh the interface to log in again.
The Monitor and Kernel in Logs section are designed for technicians to troubleshoot.
Make sure that the miner remains powered during the upgrade process.
B1+ User´s Guide
9
Copyright@2018 Bitfily Technology Co., LTD. All Rights Reserved.
Apply button to modify your password.
4)
Reboot your miner
In
Miner Control
of Logs section, click Reboot button and Confirm button, the miner will
reboot immediately.
Statement
In reboot process, the Miner Console is unavailable. After the reboot is complete, you can
log in again.