Full Text Searchable PDF User Manual
User manual
www.bvfheating.com
BVF
601
programmable room thermostat
SPECIFICATION
Operating voltage:
230V AC, 50/60 Hz
Capacity: 3600W/16A
Standby consumption:
2W
Display:
LCD White backlight
External Sensor:
NTC 10kΩ @ 20°C
IP protection rating:
IP 30
Housing:
White ABS to UL94-5 fire
standard
Temperature settings:
5°C–80°C, 0.5°C
Accuracy:
± 0.5°C
PRG options:
5+1+1, four cycles each day
Housing dimensions:
86 mm × 88 mm × 18 mm
Relay inst. dimensions:
Ø 65 mm diameter, standard
Day Indicator
Comfort Mode
Temp. up, Setting Button
Clock
Temp. display
Heating icon
Period Icons
Energy-saving Mode
Temp. down, Setting Button
PRG Mode
Modes & Parameter Setting Button
Power Button
User manual
www.bvfheating.com
CLOCK & 5+1+1 PRG SETTING
PRG function allows you to set different temperatures throughout the day. For example, you may want the home warm in the morning, cooler when you leave your
home for the day, and then warmer in the evening when you return home. The thermostat offers 5+1+1 programming option, four different temperature levels for
each day. Default comfort levels are pre-programmed; still you can change them easily with the following method:
KEY-LOCK FUNCTION
In order to avoid unauthorised access (hotels, public areas, child room) you can activate the key lock function from parameter settings page 12. To unlock your device
long press the and buttons for ~5 seconds.
DEFAULT VALUES
PARAMETER SETTINGS
WIRING DIAGRAM
Under power off mode, to access or modify parameter settings , please long press and buttons simultaneously for ~8 seconds until the MENU appear
showing 01 which is menu 1. Each press of the button will go to the next MENU.
Long press button for 5 seconds,
1.
press and to adjust the clock (min-hour-weekday), each press of will go into next time setting
2.
after clock adjustment, press to 5+1+1 mode setting. By pressing and you can set the desired time and temperature of each period. (Weekday-
period- time- temp.) Each press of button will go into next item setting.
Period
Wake up
Leave Home
Return Home
Sleep
Time
Temp.
Time
Temp.
Time
Temp.
Time
Temp.
1-5 (Mon.-Fri.)
7:00
22°C
8:30
19°C
17:00
22°C
22:00
19°C
6 (Sat.)
8:00
22°C
8:30
22°C
17:00
22°C
22:00
19°C
7 (Sun.)
8:00
22°C
8:30
22°C
17:00
22°C
22:00
19°C
Menu
Description
Range
Default
01
Temp. Offset
-8°C ~ 8°C
0
02
Set Point Max.
5°C ~ 80°C
35°C
03
Set Point Min.
5°C ~ 80°C
5°C
04
Sensor Select
ROOM
FLOOR
Room + Floor
05
Frost Protection Temp.
5°C ~15°C
5°C
06
Floor Temp. Display
Read Only
07
High Temp. Protection
20°C ~ 80°C
32°C
08
Comfort Mode Floor Limit Temp. Set
5°C ~ 35°C
29°C
09
Energy-saving Mode Floor Limit Temp. Set
5°C ~ 35°C
27°C
10
PRG Mode Floor Limit Temp. Set
5°C ~ 35°C
29°C
11
Reset rE(Yes)
12
Key lock
0 - off, 1 - on
0
7
EXTERNAL SENSOR
3600W/16A
230V/AC
6
5
4
3
2
1