background image

RC

66

 

Radio Receiver 

 

focus on productivity

 

 

 

 

Radio transmission 

 

for touch probes 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

Installation instructions 

English 

 
Type 

P03.6600-010 

 

 

 

 


background image

 

 

 


background image

 

Content

 

 

 by Blum-Novotest 2010

 

3

 

1. Safety Rules

 ................................................................................... 4

 

2. System Overview

 .......................................................................... 4

 

2.1

 Description

 ....................................................................................................... 4

 

2.2

 Display Elements

 ............................................................................................. 6

 

2.3

 Technical Data

................................................................................................ 6

 

2.4

 Area of Work

 ................................................................................................... 7

 

2.5

 Complete System

 ........................................................................................... 7

 

3. Mechanical Installation

 ............................................................... 8

 

3.1

 Mounting Variants

........................................................................................... 9

 

4. Electrical Connection

 ................................................................ 12

 

5. Maintenance

 .............................................................................. 12

 

6. Order Numbers

 ........................................................................... 12

 

7. Radio Approval

 .......................................................................... 13

 

 

 

Installation instructions interface 

IF

59-A2 

  (P03.5900-000.011) 

 
Keys: 
 

CAUTION

 

 

Important advice for appliance protection 

 

 

Advice to secondary literature  

 

Additional advice 

 

Tip 

 

 

 

LED shines 

 

LED flashes 

 

Green 

Red 

Blue 

Orange 

Violet 

 

 
Abbreviations: 
M

Tightening Torque 

 

P03.6600-000.011 
306600011_EN.docx 

02.05.2011    version: V1A 
Original operating instructions 

Subject to technical change without any 
notice

 

 

 

GN 

GN 

GN 

VT 

OG 

BU 

RD 

 


background image

Safety Rules

 

 

4

 

 by Blum-Novotest 2010

 

1.

 

Safety Rules 

 

CAUTION

 

 

Risk of short-circuit

 

Please separate connecting cable resp. plug connection off 
circuit only. 

 
 

2.

 

System Overview 

2.1

 

Description 

The radio receiver is compatible with the BLUM measuring devices 

TC

 series 

(radio probes TC60, TC63-30). The receiver enables wireless communication 
between the measuring devices and the NC control. Data transfer to the NC 
control via IF59-A2 interface. 
 

 

Fig. 2.1

 

 

(1a)  LED mode 

(2) 

cable 

(1b)  LED battery 

(3) 

for mounting screws 

(1c)  LED status 

(4) 

seal insert + O-Ring 

 

(1d)  LED receive  

 

(at horizontal cable outgoing) 

(1e)  LED transmit  

 

 

 
 
 

 

90

°

M

o

d

e

RC66

IF59-A2
P03.5900-010-A2

3

4

1a

1b

1c

1d

1e

2

 


background image

 

System Overview

 

 

 by Blum-Novotest 2010

 

5

 

 

 

Fig. 2.2

 

M

o

d

e

m

a

x

3

8

m

in

.

Ø

2

0

30

42

Ø

 4

4

9,5

Ø

 3

,3

Ø

 6

3,2

M

4

37

3

7

4

5

Ø 6,3

 


background image

System Overview

 

 

6

 

 by Blum-Novotest 2010

 

2.2

 

Display Elements 

 

LED 

LED colour  function 

MODE (1a) 
 

 

Standby  

 

Mode TC1 

 TC6 

 

Pairing procedure 

Battery (1b) 

 

 

Battery o.k. 

 

 

 

Battery low 

Status (1c) 

 

 

Initial position 

 

 

 

Probe deflected 

Receive (1d) 

 

off 

No reception  

 

 

Reception o.k. 

Transmit (1e) 

 

 

Send command 

Tab. 2.1 
 
 
 

2.3

 

 

Technical Data 

 

Protection class 

IP68 

Power supply 

12 V DC / 100 mA via IF59-A2 

Weight 

600 g 

Signal transmisson 

Radio transmission 

Frequency band: 

2,400 – 2,4835 GHz 

Transmission power 

0 dBm 

Transmitter / receiver range

 

15 m, see chap. 2.4 

Minimum bending radius 

60 mm (application: flexible) 

Max. cable length 

50 m 

Storage temperature 

-20 °C ... +70 °C 

Operating temperature 

 +5 °C ... +50 °C 

 
Tab. 2.2 

M

o

d

e

M

o

d

e

BU 

RD 

GN 

GN 

RD 

OG 

BU 

VT 

GN 

GN 

 


background image

 

System Overview

 

 

 by Blum-Novotest 2010

 

7

 

2.4

 

Area of Work 

 
 

TC60 Area of work: 

RC66 Transmitter / receiver range: 

 

Fig. 2.3 

 

 

 
 
 

2.5

 

Complete System 

 

 

Fig. 2.4

 

 

 

Switch ON/OFF via radio signal 

 

Signal transmission for 

TC 

series 

 

 

15°

30°

45°

60°

75°

15°

30°

45°

60°

75°

90°

16

14

12

10

6

15°

30°

45°

60°

75°

15°

30°

45°

60°

75°

90°

8

2

4

15°

30°

45°

60°

75°

90°

16

14

12

10

15°

30°

45°

60°

75°

90°

8

2

4

6

RC66

TC60

IF59 - A2

Z-Nano

A

u

x

TC63-30

 


background image

Mechanical Installation

 

 

8

 

 by Blum-Novotest 2010

 

3.

 

Mechanical Installation 

 

CAUTION 

 

Risk of short-circuit 

Damage by chips 
Never install cables and hoses without protection. 
Cables and hoses must always be protected against chips 
(protective hose, protection spring, cover etc.). 

CAUTION 

 

Risk of short-circuit 

Damage of the cable by sharp edges 
Pls. deburr the sharp edges on the cable bushing and 
mount edge protection! 

CAUTION

 

 

 

The system should be placed protected from coolant 
and chips.  

 

Distance between probe and receiver:  
Pay attention to chap. 2.4 

 

Keep distance to other radio systems 

 

 

 

 

 


background image

 

Mechanical Installation

 

 

 by Blum-Novotest 2010

 

9

 

3.1

 

Mounting Variants 

 

Cable outgoing horizontal: 

 

 

Pollution of the system 

Mount gasket (9a) and O-ring (9b)

 

 

       

Fig.  3.1 

 
 
 

Cable outgoing vertical:

 

                                

 

Fig.  3.2 

 

4a

4b

 


background image

Mechanical Installation

 

 

10

 

 by Blum-Novotest 2010

 

Variant 1                                                 Variant 2                    Variant 3 (option) 

 

 

Fig.  3.3 

 

(4a) 

seal insert

 

(4b) 

O-Ring 

 

(5) 

universal holder (option) 

 
 

 

Tightening torque: 
DIN912 M3x10:   M

d

 =   1,3 Nm (max.) 

DIN912 M4x10:   M

d

 =   3,0 Nm (max.) 

DIN912 M6x12:   M

d

 = 10,5 Nm (max.) 

 

Drilling template (scope of delivery) 

 

M3

M4

M6

4a

P03.5600-010.254

5

4b

P03.5600-010.080

 


background image

 

Mechanical Installation

 

 

 by Blum-Novotest 2010

 

11

 

Variant 3 
Option Universal Holder 

 

Fig.  3.4 

 
 

Variant 4: 

 

Option Front-Kit 

 

   

 

 

Pls. refer to the appropriate data sheet  

 

16

22

M6

Ø5,2

Klemmschraube
clamping screw
DIN913 M4 (2x)
M

d

 = 1,5 Nm

Schwenkbereich
swivel range

8,5

2

7

1

9

6

0

°

P03.5600-010.080

P03.6600-010.250

 


background image

Electrical Connection

 

 

12

 

 by Blum-Novotest 2010

 

4.

 

Electrical Connection

 

 

See installation instructions IF59-A2 

 
 
 

5.

 

Maintenance 

The receiver needs minimum maintenance only. 
Keep the receiver clean and free from chips. 
 

 

6.

 

Order Numbers 

 

 

 

 

Radio receiver RC66

 

 

- Cable length  

L = 10 m   PUR 

 

L = 20 m   PUR 

  (8 wires) 

 

 
 
P03.6600-010-A2-10 
P03.6600-010-A2-20 

 

 

 

 

 

 

 

Front-kit

 

P03.6600-010.250

 

 

 

 

 

 

 

 

Universal holder 

P03.5600-010.080 

 

 

 

 

 

 

 

Heavy Duty Kit 
Protection spring 1m incl. screwing 

P03.5600-010.254 

 

 

 

 

 

 

 

Interface IF59-A2 
 

P03.5900-010-A2 

 

 
 

 

 


background image

 

Radio Approval

 

 

 by Blum-Novotest 2010

 

13

 

 

7.

 

Radio Approval 

 
Area: 

Radio Approval: 

 

 

 

Regulations: 

Europe: 

       0681 

 

 

 

EN 300 328 V1.4.1,  

 

 

 

 

 

EN 301 489-17 V1.2.1,  

 

 

 

 

 

EN 60950-1:2001 

Japan: 

  R  202WW10568412

   

 

 

“This device has been granted a designation number by Ministry of 
Internal Affairs and Communications under „Ordinance concerning 
Technical Regulations Conformity Certification etc. of Specified Radio 

Equipment (

特定無線設備の技術基準適合証明等に関する規則

)“ Article 

2-1-19. 

 

USA: 

FCC ID: ZCQRCA 

 

 

 

FCC Part 15 

This device complies with part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not cause 
harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 
The antenna(s) used for this transmitter must not be co-located or 
operating in conjunction with any other antenna or transmitter. 
 

 
Canada: 

IC:9570A-RCA 

 

 

Operation is subject to the following two conditions: (1) this device may 
not cause interference, and (2) this device 
must accept any interference, including interference that may cause 
undesired operation of the device. 
This device and its antenna(s) must not be co-located or operating in 
conjunction with any other antenna or transmitter. 
 
This equipment complies with IC Canada RF radiation exposure limits 
set forth for an uncontrolled environment as per RSS-102 Issue 4. 

 
 

 


background image

 

 

14

 

 by Blum-Novotest 2010

 

EC Declaration of Incorporation 

 

acc. to the EC Machine Regulations 2006/42/EC in the edition from 17 May.2006 
 

 

 
We  hereby  confirm  that  the  subsequently  following  components  are  defined  for  the 
installation  into  other  machines  and  that  they  are  in  accordance  with  the  following 
safety requirements of the EC regulations. 
 
Commissioning  is  not  allowed  until  it  is  ascertained  that  the  machines,  in  which  the 
components are installed, are in accordance with the EC regulations 2006/42/EC. 
 
The relevant technical information is compiled acc. to annex VII part B and, where 
appropriate, we will send the information concerning the components to the different 
countries. The industrial property rights of Blum-Novotest GmbH will remain unaffected.  
 
Component name: 

P03.6600   

 

Radio receiver 

Safety requirements 
2006/42/EG, Annex I 

1.5.1 

 
Applied standards: 
EC-Regulations: 

2004/108/EG 

 

2006/95/EG 

 

1999/5/EG 

 
Applied harmonized standards: 

EN61000-6 

 

EN60204-1 

 

EN ISO 12100 

 

EN 300 328 

 

EN 301 489-17 

 

EN 60950-1:2001 

 
 
Applied national standards: 

DIN VDE 0100 

 

DIN VDE 0113 

 
Authorised presentative for technical information: 

Blum-Novotest GmbH 

 

Kaufstr. 14 

 

88287 Gruenkraut, Germany 

 

 

 


background image

 

 

 by Blum-Novotest 2010

 

15

 

Service Order 

 

Please fill out completely this repair order and attach it to the system. This will 
save you and us costs due to time-consuming inquiries and ensures a quick 
repair. 

 

Blum-Novotest GmbH 

Kaufstr. 14,  88287 Gruenkraut/Gullen - Germany 
Tel.  +49 751 6008-0,   Fax. +49 751 6008-156

 

 

Company:

 

 

Department:

 

 

Contact: 

 

Address:

 

 

Phone:

 

 

Fax: 

 

Email:

 

 

Probe Type, Serial No.: 

 

Machine Type, 
Manufacturer: 

 

Description of Defect: 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

 

 

focus on productivity

focus on productivity

 

Blum-Novotest GmbH  
Kaufstr. 14  
88287 Gruenkraut, Germany 
Tel.:+49 751 6008-0 
Fax:+49 751 6008-156 
www.blum-novotest.com 
vk@blum-novotest.com 
 

 

Hotline:

  

Vertrieb/sales: 

Tel.:+49 751 6008-200 

Service LaserControl :  

Tel.:+49 751 6008-202 

Service Messtaster/probes:  Tel.:+49 751 6008-203 
 
 

Blum-Novotest GmbH Prüftechnik 

KK Blum Laser Measuring Technology 

Willich, Germany 

Nagoya, Japan 

Tel. +49 2154 921970 

Tel. +81 568 74-5311 

 

Blum-Novotest Srl 

Blum-Novotest 

Como, Italy 

Shanghai, China 

Tel. +39 031 283 955 

Tel. +86 21 52080480 

 

Blum-Novotest Ltd. 

Blum Production Metrology Co., Ltd. 

Birmingham, England 

Taichung, Taiwan 

Tel. +44 1543 257111 

Tel. +886 4 2358 3900 

 

Blum Laser Measuring Technology Inc. 

Blum Production Metrology Pte. Ltd. 

Cincinnati, USA 

Singapore, Singapore 

Tel. +1 859 3446789 

Tel. +65 62720998 

 

Blum-Novotest Sarl 

Blum-Novotest Ltd. 

Bordeaux, France 

Soul, Republic of Korea 

Tel. +33 55702 0135 

Tel. +82 2 2026-1300 

 
Blum-Novotest s.r.o. 
Kroměříž, Czech Republic 
Tel. +420 573 330373 
 

 

Support