Full Text Searchable PDF User Manual
Adande
®
Refrigeration
Operations Manual
Contents
Page
1
What is the Adande
®
System
3
2
Adande
®
Technology Explained
3
3
EC Declaration of Conformity
4
4
Storage of Product
5
5
Operating Adande
®
Temperature Settings
5
5.1
The Display Controls
5
5.2
Defrost
7
5.3
Drawer Alarm
7
5.4
Error Alarm
7
5.5
Temperature Alarm
7
5.6
Electrical Connection
8
5.7
Location and Stability
9
5.8
Servicing
10
6
General Warning and safety Precautions
10
6.1
Electrical
10
6.2
Food
10
6.3
General
10
7
Unit Maintenance
11
ADE- 2015-B
Page 2
8
Contact details
12
Welcome to Adande
®
Refrigeration
1
What is Adande
®
?
Adande
®
is a new method of cold storage developed as a series of insulated drawers, that
each offer storage temperature flexibility in 1ºC increments between –22ºC and +15ºC.
Each insulated drawer:-
•
Provides stable temperature storage
•
Is removable to act as temporary, cool and safe product storage.
•
Gives full plan area access providing space efficient storage.
•
Is easily cleaned or replaced.
2
Adande
®
Explained
Adande
®
uses standard technology and refrigeration parts but in a completely new and
patented way.
A dedicated fridge engine supplies refrigerant to an evaporator coil assembly. The
evaporator coil assembly then supplies cooling to the insulated drawer and is sized to
maintain up to 40kg of product at any set point temperature, in the range of –22ºC to
+15ºC.
Figure 1: Front view of Adande
®
Single Drawer unit
ADE- 2015-B
Page 3
3
EC Declaration of Conformity
We declare that the following machinery complies with the essential health and safety
requirements of:-
The Machinery Directive 2006/42/EC
The Low Voltage Directive 2006/95/EC
The Electromagnetic Compatibility Directive 2004/108/EC
The Pressure Equipment Directive 97/23/EC
Machinery Description: 1 Drawer Appliance for Chilled Storage.
Make: Adande
®
.
Type: Adande
®
Drawer Refrigeration Units
Manufactured by Adande
®
Refrigeration Ltd.,
Units 4 -9 Harvest Court, South Lowestoft Industrial Estate, Lowestoft, Suffolk NR33 7NB
The following transposed harmonised European Standards have been used:
EN ISO 12100 parts 1 & 2 Safety of Machinery – Basic concepts, general principles for design
EN ISO 13857 Safety of Machinery – Safety distances to prevent danger zones being reached
by the upper and lower limbs.
EN ISO 13732-1: 2006 Ergonomics of the thermal environment -- Methods for the assessment of
human responses to contact with surfaces -- Part 1: Hot surfaces
EN 1672-2 Food processing machinery – Basic concepts – Part 2 : Hygiene requirements
EN 61000-6-3:2001, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards;
Emission standard for residential, commercial and light- industrial environments
EN 61000-6-1 Generic Immunity Standard; Residential commercial and light industrial
environments.
EN 60335-2-24 The Safety of Household and Similar Electrical Appliances – Part 2 –24:
Particular Requirements for Refrigerating Appliances and Ice Makers.
The technical file for this machinery will be prepared on demand by :-
Name: Ian Wood
Position: Managing Director
Who signs on behalf of the manufacturer
ADANDE
®
REFRIGERATION
Units 4 – 9 Harvest Court
South Lowestoft Industrial Estate
Lowestoft
Suffolk
NR33 7NB
.
ADE- 2015-B
Page 4
4
Storage of Product
For the unit to operate at full efficiency the drawer seal should be maintained in good
condition. It is essential that the product is not stored above the
“MAX FILL LEVEL”
line
as this can damage the seal and affect the operation of the unit.
The unit is capable of storing any food product. However, products which may give off
acidic odours like vinegar, onions, etc should be suitably sealed. Adande
®
also
recommends containers with liquid food products be stored with lids.
Ensure that the product is never stacked above the
“MAX FILL LEVEL”
Label in the
drawer.
5
Operating Adande
®
- Temperature Settings
The Adande
®
temperature control system allows you to set and control the drawer within a
temperature range of -22°C ( -8°F) and +15°C (59°F).
Temperature accuracy in the drawer will be maintained within ±2ºC of the set point.
5.1
The Display Controls
To adjust the temperature set point (figure 2) press and hold the “i” button, the drawer set
point will then be displayed. While holding the “i” button increase or decrease temperature
using the arrow buttons, on release of both buttons the new set point will be stored.
Figure 2: Adande
®
Display Control Panel
Decrease
temperature
Increase
temperature
Manual
defrost
Power On/
Off
Set
temperature
ADE- 2015-B
Page 5
The controller can be locked to avoid accidental modification of drawer set point
temperature.
a)
Press and immediately release
“i”
button
to display ‘T1’
b)
Press button
“i”
again to display ‘T2’
c)
Press button
“i”
again to display ‘TH1’
d)
Press button
“i”
again to display ‘TLO’
e)
Press button
“i”
again to display ‘CND’
f)
Press button
“i”
again to display ‘LOC’
g)
Hold the
“i”
button to display either yes
or no
h)
Press either of the
or
buttons to
change yes/no setting
Figure 3: Locking Adande
®
Display Control Panel
ADE- 2015-B
Page 6
5.2
Defrost
The refrigeration system automatically defrosts. If a manual defrost is required then press
the manual defrost button on the control panel for 3 seconds.
5.3
Drawer Alarm
If the drawer is open for more than 10 minutes, the display in the control panel changes to
“DO”.
When the alarm has been activated, the Adande
®
unit will alarm both visually and audibly.
To silence the audible alarm, press ANY button on the display, or close the drawer. The
alarm light and flashing display will continue to show until the drawer has been fully closed.
NOTE: THERE IS NO COOLING TO THE DRAWER WHEN THE DRAWER IS OPEN.
5.4
Error Alarm
If display reads
“E1
” or
“E2”
, a temperature probe has failed, and an engineer should be
called.
The Adande
®
unit will operate with a 15 minute on / 15 minute off cycle in the event of an
“E1”
failure. This will help to maintain the stored product at a safe temperature, but
precise temperature control will be lost.
“E2”
will only affect defrosts, and these will be
timed to maintain operation of the unit. An engineer should be called as soon as possible
for either fault.
5.5
Temperature Alarm
Should
“HI”
appear on the display, the drawer temperature has exceeded its set point by
7°C. Product core temperature should be inspected. If the Adande
®
unit has recently been
turned on, loaded with warm product or left open for a long period, this alarm could be
displayed. If the temperature does not return to the set point temperature, an engineer
should be called.
Should
“LO”
appear on the display, the drawer temperature has fallen below its set point
by 7°C. Product core temperature should be inspected. If the Adande
®
unit drawer
temperature set point has recently been increased, this alarm could be displayed. If the
temperature does not return to the set point temperature, an engineer should be called.
ADE- 2015-B
Page 7
5.6
Electrical Connection
The Adande
®
drawer unit should be connected to a 230V, single phase, 50 Hz, standard
socket outlet supply. The unit is connected to the mains supply with a detachable supply
lead, one end of which is fitted with a standard 13 amp 3 pin plug (fused at 13A). The
other end of the supply lead, fitted with an appliance plug, is connected to the Adande
®
unit as shown in figure 3a below.
Figure 3a: Mains connection point
The unused socket on the right hand side in figure 3a can be used to provide a mains
supply to additional Adande
®
units as shown in figure 3b below.
Figure 3b: Mains connection point
DO NOT REMOVE ACCESS PANELS WITH THE ELECTRICAL SUPPLYCONNECTED.
Single ‘P’clip
for retaining
mains cable
2 off ‘P’ clips for
retaining mains
cable and link cable
to other unit
Single ‘P’clip
for retaining
mains cable
ADE- 2015-B
Page 8
5.7
Location and Stability
It is important that the Adande
®
unit is installed and maintained on a flat, clean and
level
surface
to ensure correct operation.
The room should be dry and sufficiently ventilated.
Optimum performance is obtained at ambient temperatures between +16ºC (60ºF) and
+38ºC (100ºF).
Ensure that no obstructions are placed directly in front of the air outlet grille.
The Adande
®
drawer unit can be mounted on rubber feet, rollers or castors. When
mounted on a castor base, the front two castors should have their brakes ON during
normal use as in figure 4.
Figure 4: Lockable Castor
If the Adande
®
unit is mounted on two rollers at the rear of the unit, and rubber feet at the
front, to move the unit, lift the front of the unit as in figure 5 and push or pull the unit into
position.
Figure 5: Lifting unit to move when on rollers and feet
THE UNIT SHOULD BE UNLOADED BEFORE MOVING
ADE- 2015-B
Page 9
5.8
Servicing
Service personnel must be suitably trained in refrigeration and experienced in servicing
Adande
®
units
Select only from the list of Adande
®
Approved and Registered Service Engineers.
REGULAR SERVICING AT 12 MONTHLY INTERVALS IS ESSENTIAL TO RETAIN THE
WARRANTY CONDITION.
ACCESS PANELS MUST NOT BE REMOVED BY UNTRAINED PERSONNEL
Advice and help can be obtained to resolve any problems that may occur during operation
or servicing, by contacting the Adande
®
technical support line, refer to Appendix 1 at the
back of this manual.
6 General Warning and Safety Precautions
6.1 Electrical
•
Untrained personnel should not remove any of the access panels.
•
The access panels should not be removed with the electrical supply connected.
•
To disconnect the electrical supply, remove the plug from the electrical socket.
6.2 Food
•
Use only a soft cloth, water or mild soap solutions to clean the unit.
•
Do not use hard brushes or other items for cleaning.
•
Remove any food which may have accidentally dropped from the food preparation
surface into an open drawer or drawer runners.
•
Do not leave drawers open for longer periods of time than necessary.
•
If units are stacked, avoid opening more than one drawer at a time.
•
Ensure products that give out acidic odours like vinegar, onions, etc. are sealed
before storage in the unit.
6.3 General
•
Do not exceed the maximum fill level or loading of 40kg per drawer.
•
Do not sit, stand or apply additional downward pressure on an open drawer.
•
Do not operate unit with any panels removed.
•
Do not clean unit with any panels removed.
•
Ensure unit is installed and maintained on a flat, clean and level surface.
•
If mounted on a castor base, ensure brakes are applied to the front two castors to
keep unit stationary at one location.
ADE- 2015-B
Page 10
•
Room in which the unit is kept should be dry and sufficiently ventilated.
•
No obstructions should be placed directly in front of the condenser air outlet.
•
Unit should be serviced at least once every 12 months.
7.0 Unit Maintenance
The airflow through the Adande unit is
designed to deposit grease and dirt on
the
outside
surface of the insulated
drawer and
internal
surfaces of the
drawer housing.
The insulated drawer must be removed
from the unit to clean these surfaces.
These dirt and grease deposits should be removed weekly using the following procedures:
1. Clean the gasket on a
weekly
or daily
basis if required with a solution of warm
water and mild detergent.
2. The insulated drawer can be totally
removed from the unit for deep
cleaning. Clean the insulated
drawer with an anti-bacterial
cleanser.
NOTE: DO NOT USE SHARP UTENSILS
3. Brush any loose dirt from the condenser.
ADE- 2015-B
Page 11
4. Clean the steel surfaces with a polish
cleaner.
NOTE:
DO NOT USE STEEL PADS, WIRE BRUSHES,
SCRAPERS OR CHLORIDE CLEANERS TO
CLEAN STAINLESS STEEL.
NOTE:
DO NOT PRESSURE WASH EQUIPMENT AS DAMAGE TO ELECTRICAL
COMPONENTS MAY RESULT.
8 Appendix 1: Contact Details
Stoddart Food Service Equipment
Service & Spare Parts - 1300 307 289
Sales - 1300 79 1954
ADE- 2015-B
Page 12