PDF User Manual

  1. Home
  2. Manuals
  3. Adande VCS Operation Manual

Adande VCS Operation Manual

Made by: Adande
Type: Operation Manual
Category: Chiller
Pages: 12
Size: 4.16 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Adande

®

 Refrigeration 

 

 

Operations Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 


background image

 

Contents

 

 

 

 

 

 

 

 

 

 

Page 

 
1

 

What is the Adande

®

 System 

 

 

 

 

 

 

2

 

Adande

®

 Technology Explained   

 

 

 

 

 

3

 

EC Declaration of Conformity 

 

 

 

 

 

 

4

 

Storage of Product   

 

 

 

 

 

 

 

5

 

Operating Adande

®

 Temperature Settings 

 

 

 

 

5.1

 

The Display Controls

 

 

 

 

 

 

 

5.2

 

Defrost

 

 

 

 

 

 

 

 

 

5.3

 

Drawer Alarm

 

 

 

 

 

 

 

 

5.4

 

Error Alarm

   

 

 

 

 

 

 

 

5.5

 

Temperature Alarm

   

 

 

 

 

 

 

5.6

 

Electrical Connection

 

 

 

 

 

 

 

5.7

 

Location and Stability

 

 

 

 

 

 

 

5.8 

Servicing 

 

 

 

 

 

 

 

10

 

 

6

 

General Warning and safety Precautions 

 

 

 

10 

 

 

6.1

 

Electrical

 

 

 

 

 

 

 

 

10 

 

6.2

 

Food

   

 

 

 

 

 

 

 

10 

 

6.3

 

General

 

 

 

 

 

 

 

 

10 

 

 

 

 

 

 

7

 

Unit Maintenance   

 

 

 

 

 

 

11 

 

 

ADE- 2015-B 

 

Page 2 

8

 

Contact details 

 

 

 

 

 

 

 

 

12

 


background image

 

Welcome to Adande

®

 Refrigeration 

 

What is Adande

®

 

Adande

®

 is a new method of cold storage developed as a series of insulated drawers, that 

each offer storage temperature flexibility in 1ºC increments between –22ºC and +15ºC. 
 
Each insulated drawer:- 
 

  Provides stable temperature storage 

  Is removable to act as temporary, cool and safe product storage. 

  Gives full plan area access providing space efficient storage.  

  Is easily cleaned or replaced. 

 

 

Adande

®

 Explained 

 
Adande

®

  uses  standard  technology  and  refrigeration  parts  but  in  a  completely  new  and 

patented way. 
 
A  dedicated  fridge  engine  supplies  refrigerant  to  an  evaporator  coil  assembly.  The 
evaporator  coil  assembly  then  supplies  cooling  to  the  insulated  drawer  and  is  sized  to 
maintain  up  to  40kg  of  product  at  any  set  point  temperature,  in  the  range  of  –22ºC  to 
+15ºC. 

 

Figure 1: Front view of Adande

®

 Single Drawer unit 

 

 
 
 
 

ADE- 2015-B 

 

Page 3 

 


background image

 

EC Declaration of Conformity 

 
 
 
 
 
 
 
 
 
 

 

We declare that the following machinery complies with the essential health and safety 
requirements of:-  
 
The Machinery Directive 2006/42/EC 
The Low Voltage Directive 2006/95/EC 
The Electromagnetic Compatibility Directive 2004/108/EC 
The Pressure Equipment Directive 97/23/EC 
 
Machinery Description: 1 Drawer Appliance for Chilled Storage. 
Make: Adande

®

.  

Type: Adande

®

 Drawer Refrigeration Units 

Manufactured by Adande

®

 Refrigeration Ltd., 

Units 4 -9 Harvest Court,   South Lowestoft Industrial Estate,   Lowestoft,   Suffolk   NR33 7NB  
 
The following transposed harmonised European Standards have been used: 
 
EN ISO 12100 parts 1 & 2 Safety of Machinery – Basic concepts, general principles for design 
EN ISO 13857 Safety of Machinery – Safety distances to prevent danger zones being reached 
by the upper and lower limbs. 
EN ISO 13732-1: 2006 Ergonomics of the thermal environment -- Methods for the assessment of 
human responses to contact with surfaces -- Part 1: Hot surfaces 
EN 1672-2 Food processing machinery – Basic concepts – Part 2 : Hygiene requirements 
EN 61000-6-3:2001, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards; 
Emission standard for residential, commercial and light- industrial environments  
EN 61000-6-1 Generic Immunity Standard; Residential commercial and light industrial 
environments. 
EN 60335-2-24 The Safety of Household and Similar Electrical Appliances – Part 2 –24: 
Particular Requirements for Refrigerating Appliances and Ice Makers. 
 
The technical file for this machinery will be prepared on demand by :- 
 
Name: Ian Wood 
Position: Managing Director 
Who signs on behalf of the manufacturer 
 
ADANDE

®

 REFRIGERATION 

Units 4 – 9 Harvest Court 
South Lowestoft Industrial Estate 
Lowestoft 
Suffolk 
NR33 7NB

ADE- 2015-B 

 

Page 4 

 


background image

 

Storage of Product 

 
For the unit to operate at full efficiency the drawer seal should be maintained in good 
condition. It is essential that the product is not stored above the 

“MAX FILL LEVEL”

 line 

as this can damage the seal and affect the operation of the unit. 
 
The  unit  is  capable  of  storing  any  food  product.  However,  products  which  may  give  off 
acidic  odours  like  vinegar,  onions,  etc  should  be  suitably  sealed.  Adande

®

  also 

recommends containers with liquid food products be stored with lids. 
 
Ensure  that  the  product  is  never  stacked  above  the 

“MAX  FILL  LEVEL”

  Label  in  the 

drawer.  
 

 

Operating Adande

®

 - Temperature Settings 

 
The Adande

®

 temperature control system allows you to set and control the drawer within a 

temperature range of -22°C ( -8°F) and +15°C (59°F). 
 
Temperature accuracy in the drawer will be maintained within ±2ºC of the set point. 

 

5.1

 

The Display Controls

 

 

To adjust the temperature set point (figure 2) press and hold the “i” button, the drawer set 
point will then be displayed. While holding the “i” button increase or decrease temperature 
using the arrow buttons, on release of both buttons the new set point will be stored.

 

 

 

 

 

 
 
 

 
 

Figure 2: Adande

®

 Display Control Panel 

 
 

 
 

Decrease

 

temperature

 

Increase 
temperature 

Manual 
defrost 

Power On/ 
Off 

Set

 

temperature

 

ADE- 2015-B 

 

Page 5 

 


background image

 

The controller can be locked to avoid accidental modification of drawer set point 
temperature. 
 
 

 

a)

 Press and immediately release 

“i”

 button 

to display ‘T1’

 

b)

 Press button 

“i”

 again to display ‘T2’ 

 

 

c)

 Press button 

“i”

again to display ‘TH1’

 

d)

 Press button 

“i”

again to display ‘TLO’ 

 

 

e)

 Press button 

“i”

again to display ‘CND’

 

f)

 Press button 

“i”

again to display ‘LOC’

 

 

 

g)

 Hold the 

“i” 

button to display either yes 

or no

 

h) 

Press either of the  

 or 

buttons  to 

change yes/no setting

 

 

Figure 3: Locking Adande

®

 Display Control Panel

 

 
 

ADE- 2015-B 

 

Page 6 

 


background image

 

 
5.2 

Defrost 

 
The refrigeration system automatically defrosts. If a manual defrost is required then press 
the manual defrost button on the control panel for 3 seconds. 

 

5.3 

Drawer Alarm 

 
If the drawer is open for more than 10 minutes, the display in the control panel changes to 
“DO”. 
 
When the alarm has been activated, the Adande

®

 unit will alarm both visually and audibly. 

 
To silence  the  audible alarm, press ANY  button  on  the  display,  or close  the drawer.  The 
alarm light and flashing display will continue to show until the drawer has been fully closed. 
 
 

NOTE: THERE IS NO COOLING TO THE DRAWER WHEN THE DRAWER IS OPEN.

 

 

 

5.4 

Error Alarm 

 
If display reads 

“E1

” or 

“E2”

, a temperature probe has failed, and an engineer should be 

called.   
 
The Adande

®

 unit will operate with a 15 minute on / 15 minute off cycle in the event of an 

“E1”

  failure.  This  will  help  to  maintain  the  stored  product  at  a  safe  temperature,  but 

precise  temperature  control  will  be  lost.   

“E2”

  will  only  affect  defrosts,  and  these  will  be 

timed to maintain operation of the unit. An engineer should be called as soon as possible 
for either fault. 

 

5.5 

Temperature Alarm 

 
Should 

“HI”

 appear on the display, the drawer temperature has exceeded its set point by 

7°C. Product core temperature should be inspected. If the Adande

®

 unit has recently been 

turned  on,  loaded  with  warm  product  or  left  open  for  a  long  period,  this  alarm  could  be 
displayed.    If  the  temperature  does  not  return  to  the  set  point  temperature,  an  engineer 
should be called. 
 
Should 

“LO” 

appear on the display, the drawer temperature has fallen below its set point 

by  7°C.  Product  core  temperature  should  be  inspected.  If  the  Adande

®

  unit  drawer 

temperature  set  point  has  recently  been  increased,  this  alarm  could  be  displayed.  If  the 
temperature does not return to the set point temperature, an engineer should be called. 
 

 
 
 
 
 
 

ADE- 2015-B 

 

Page 7 

 


background image

 

5.6 

Electrical Connection 

 
The Adande

®

 drawer unit should be connected to a 230V, single phase, 50 Hz, standard 

socket outlet supply. The unit is connected to the mains supply with a detachable supply 
lead,  one  end  of  which  is  fitted  with  a  standard  13  amp  3  pin  plug  (fused  at  13A).    The 
other  end  of  the  supply  lead,  fitted  with  an  appliance  plug,  is  connected  to  the  Adande

®

 

unit as shown in figure 3a below. 
 

 

 

Figure 3a: Mains connection point 

 
The unused socket on the right hand side in figure 3a can be used to provide a mains 
supply to additional Adande

®

 units as shown in figure 3b below. 

 

 

 

Figure 3b: Mains connection point 

 
DO NOT REMOVE ACCESS PANELS WITH THE ELECTRICAL SUPPLYCONNECTED. 

Single ‘P’clip 
for retaining 
mains cable 

2 off ‘P’ clips for 
retaining mains 
cable and link cable 
to other unit 

Single ‘P’clip 
for retaining 
mains cable 

ADE- 2015-B 

 

Page 8 

 


background image

 

5.7 

Location and Stability 

 
It is important that the Adande

® 

unit is installed and maintained on a flat, clean and 

level 

surface

 to ensure correct operation. 

 
The room should be dry and sufficiently ventilated. 
 
Optimum  performance  is  obtained  at  ambient  temperatures  between  +16ºC  (60ºF)  and 
+38ºC (100ºF). 
 
Ensure that no obstructions are placed directly in front of the air outlet grille. 
 
The  Adande

®

  drawer  unit  can  be  mounted  on  rubber  feet,  rollers  or  castors.  When 

mounted  on  a  castor  base,  the  front  two  castors  should  have  their  brakes  ON  during 
normal use as in figure 4. 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

Figure 4: Lockable Castor 

 
If the Adande

®

 unit is mounted on two rollers at the rear of the unit, and rubber feet at the 

front, to move the unit, lift the front of the unit as in figure 5 and push or pull the unit into 
position. 

 
 
 
 
 
 
 
 
 
 

 

Figure 5: Lifting unit to move when on rollers and feet  

 

THE UNIT SHOULD BE UNLOADED BEFORE MOVING 

 
 

ADE- 2015-B 

 

Page 9 

 


background image

 

5.8 

Servicing 

Service  personnel  must  be  suitably  trained  in  refrigeration  and  experienced  in  servicing 
Adande

®

 units 

 
Select only from the list of Adande

®

 Approved and Registered Service Engineers. 

 
REGULAR SERVICING AT 12 MONTHLY INTERVALS IS ESSENTIAL TO RETAIN THE 
WARRANTY CONDITION. 
 

ACCESS PANELS MUST NOT BE REMOVED BY UNTRAINED PERSONNEL 

 
Advice and help can be obtained to resolve any problems that may occur during operation 
or servicing, by contacting the Adande

®

 technical support line, refer to Appendix  1 at the 

back of this manual. 

 

6 General Warning and Safety Precautions 

6.1 Electrical 

  Untrained personnel should not remove any of the access panels. 

  The access panels should not be removed with the electrical supply connected. 

  To disconnect the electrical supply, remove the plug from the electrical socket. 

 

6.2 Food 

  Use only a soft cloth, water or mild soap solutions to clean the unit. 

  Do not use hard brushes or other items for cleaning. 

  Remove any food which may have accidentally dropped from the food preparation 

surface into an open drawer or drawer runners. 

  Do not leave drawers open for longer periods of time than necessary. 

  If units are stacked, avoid opening more than one drawer at a time. 

  Ensure  products  that  give  out  acidic  odours  like  vinegar,  onions,  etc.  are  sealed 

before storage in the unit. 

 

6.3 General 

  Do not exceed the maximum fill level or loading of 40kg per drawer. 

  Do not sit, stand or apply additional downward pressure on an open drawer. 

  Do not operate unit with any panels removed.  

  Do not clean unit with any panels removed. 

  Ensure unit is installed and maintained on a flat, clean and level surface. 

  If mounted on a castor base, ensure brakes are applied to the front two castors to 

keep unit stationary at one location. 

ADE- 2015-B 

 

Page 10

 


background image

 

  Room in which the unit is kept should be dry and sufficiently ventilated. 

  No obstructions should be placed directly in front of the condenser air outlet. 

  Unit should be serviced at least once every 12 months. 

 

7.0 Unit Maintenance 

 

 

The  airflow  through  the  Adande  unit  is 
designed  to  deposit  grease  and  dirt  on 
the 

outside

  surface  of  the  insulated 

drawer  and 

internal

  surfaces  of  the 

drawer housing. 
  
The  insulated  drawer  must  be  removed 
from the unit to clean these surfaces.

 

 

These dirt and grease deposits should be removed weekly using the following procedures: 

 

1. Clean the gasket on a 

weekly

 or daily 

basis if required with a solution of warm 
water and mild detergent. 

 

2.  The insulated drawer can be totally 

removed from the unit for deep 
cleaning. Clean the insulated 
drawer with an anti-bacterial 
cleanser. 

 

 

NOTE: DO NOT USE SHARP UTENSILS 

3.  Brush any loose dirt from the condenser. 

 

 

 

 

ADE- 2015-B 

 

Page 11

 


background image

 

4.  Clean the steel surfaces with a polish 

cleaner.  

 

NOTE:

 

 

DO NOT USE STEEL PADS, WIRE BRUSHES, 
SCRAPERS  OR CHLORIDE CLEANERS TO 
CLEAN STAINLESS STEEL. 

 

 

 

 

 

 

 

NOTE:

 

DO NOT PRESSURE WASH EQUIPMENT AS DAMAGE TO ELECTRICAL 

 

COMPONENTS MAY RESULT.

 

 

8 Appendix 1: Contact Details 

Stoddart Food Service Equipment

Service & Spare Parts - 1300 307 289

Sales - 1300 79 1954

ADE- 2015-B 

 

Page 12